summaryrefslogtreecommitdiffstats
path: root/upstream/fedora-40/man5/sane-umax.5
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-15 19:43:11 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-15 19:43:11 +0000
commitfc22b3d6507c6745911b9dfcc68f1e665ae13dbc (patch)
treece1e3bce06471410239a6f41282e328770aa404a /upstream/fedora-40/man5/sane-umax.5
parentInitial commit. (diff)
downloadmanpages-l10n-fc22b3d6507c6745911b9dfcc68f1e665ae13dbc.tar.xz
manpages-l10n-fc22b3d6507c6745911b9dfcc68f1e665ae13dbc.zip
Adding upstream version 4.22.0.upstream/4.22.0
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'upstream/fedora-40/man5/sane-umax.5')
-rw-r--r--upstream/fedora-40/man5/sane-umax.5284
1 files changed, 284 insertions, 0 deletions
diff --git a/upstream/fedora-40/man5/sane-umax.5 b/upstream/fedora-40/man5/sane-umax.5
new file mode 100644
index 00000000..bc9b8364
--- /dev/null
+++ b/upstream/fedora-40/man5/sane-umax.5
@@ -0,0 +1,284 @@
+.TH sane\-umax 5 "14 Jul 2008" "" "SANE Scanner Access Now Easy"
+.IX sane\-umax
+
+.SH NAME
+sane\-umax \- SANE backend for UMAX scanners
+
+.SH ABOUT THIS FILE
+
+This file is only a brief description of the
+.B sane\-umax
+backend for SANE! For detailed information take a look at
+sane\-umax\-doc.html (it is included in the sane source directory and in the
+.BR xsane (1)
+online help)!
+
+.SH DESCRIPTION
+
+The
+.B sane\-umax
+library implements a SANE backend that provides access to several UMAX-SCSI-scanners and some Linotype Hell SCSI-scanners,
+parallel- and USB-scanners are not (and probably will never be) supported!
+
+.B I suggest you hold one hand on the power-button of the scanner while you try the first scans!
+
+.SH CONFIGURATION
+
+The configuration file for this backend resides in
+.IR /etc/sane.d/umax.conf .
+
+Its contents is a list of device names that correspond to UMAX and UMAX compatible scanners. Empty lines
+and lines starting with a hash mark (#) are ignored. A sample configuration file is
+shown below:
+
+.nf
+ # this is a comment
+ #
+ option scsi\-maxqueue 4
+ option scsi\-buffer\-size\-min 65536
+ option scsi\-buffer\-size\-max 131072
+ option scan\-lines 40
+ option preview\-lines 10
+ option scsi\-maxqueue 2
+ option execute\-request\-sense 0
+ option force\-preview\-bit\-rgb 0
+ option slow\-speed \-1
+ option care\-about\-smearing \-1
+ option calibration\-full\-ccd \-1
+ option calibration\-width\-offset \-1
+ option calibration\-bytes\-pixel \-1
+ option exposure\-time\-rgb\-bind \-1
+ option invert\-shading\-data \-1
+ option lamp\-control\-available 0
+ option gamma\-lsb\-padded 0
+ /dev/sge
+\
+ #scsi Vendor Model Type Bus Channel ID LUN
+ # The following scanner supports lamp control
+ option lamp\-control\-available 1
+ scsi UMAX * Scanner * * * * *
+\
+ # scanner on /dev/scanner does not support lamp control
+ option lamp\-control\-available 0
+ /dev/scanner
+.fi
+
+.TP
+execute\-request\-sense:
+values: 0 = disabled, 1 = enabled
+.br
+default = 0
+.br
+If set to 1,
+.BR umax_do_request_sense ()
+is called in
+.BR umax_do_calibration ().
+This can hang the system, but has been enabled until this version.
+.TP
+scsi\-buffer\-size\-min, scsi\-buffer\-size\-max:
+values: 4096-1048576
+.br
+default min = 32768, max = 131072
+.br
+Especially the minimum value is very important.
+If this value is set too small the backend is not
+able to send gamma tables to the scanner or to
+do a correct color calibration. This may result in
+strange color effects. If the minimum value is set
+too large then the backend is not able to allocate
+the requested SCSI buffer size and aborts with
+out of memory error. The default is 32KB, for
+some scanners it should be increased to 64KB.
+.TP
+scan\-lines, preview\-lines:
+values: 1-65535
+.br
+default: scan\-lines = 40, preview\-lines = 10
+.br
+define the maximum number of lines that are scanned
+into one buffer
+.TP
+force\-preview\-bit\-rgb:
+values:
+0 = disabled,
+1 = enabled
+.br
+default = 0
+.br
+set preview bit in rgb real scan
+.TP
+slow\-speed, care\-about\-smearing:
+values:
+\-1 = auto,
+0 = disabled,
+1 = enabled
+.br
+default = \-1
+.br
+Dangerous options, needed for some scanners.
+.br
+Do not change these options unless you really know
+what you are doing otherwise you may destroy your scanner
+with invalid values.
+.TP
+calibration\-full\-ccd:
+values:
+\-1 = auto,
+0 = disabled,
+1 = enabled
+.br
+default = \-1
+.br
+do calibration for each pixel of ccd instead of
+selected image
+.TP
+calibration\-width\-offset:
+values: \-99999 = auto, > \-99999 set value
+.br
+add an offset to the calculated width for image/ccd
+.TP
+calibration\-bytes\-pixel:
+values:
+\-1 = disabled,
+0 = not set,
+1 = 1 byte/pixel,
+2 = 2 bytes/pixel
+.br
+use # bytes per pixel for calibration
+.TP
+exposure\-time\-rgb\-bind:
+values:
+\-1 = automatically set by driver \- if known,
+0 = disabled (own selection for red, green and blue),
+1 = enabled (same values for red, green and blue)
+.TP
+invert\-shading\-data:
+values:
+\-1 = automatically set by driver \- if known,
+0 = disabled,
+1 = enabled
+.br
+default = \-1
+.br
+invert shading data before sending it back to the scanner
+.TP
+lamp\-control\-available:
+values:
+0 = automatically set by driver \- if known,
+1 = available
+.br
+default = 0
+.TP
+gamma\-lsb\-padded:
+values:
+\-1 = automatically set by driver \- if known,
+0 = gamma data is msb padded,
+1 = gamma data is lsb padded
+.br
+default = \-1
+.TP
+handle\-bad\-sense\-error:
+values:
+0 = handle as device busy,
+1 = handle as ok,
+2 = handle as i/o error,
+3 = ignore bad error code \- continue sense handler
+.br
+default = 0
+.TP
+scsi\-maxqueue:
+values:
+1..# (maximum defined at compile time)
+.br
+default = 2
+.br
+most SCSI drivers allow internal command queueing with a depth
+of 2 commands. In most cases it does not improve anything when you
+increase this value. When your SCSI driver does not support any
+command queueing you can try to set this value to 1.
+
+.PP
+The special device name must be a generic SCSI device or a symlink to such a device.
+To find out to which device your scanner is assigned and how you have to set the
+permissions of that device, have a look at
+.BR sane\-scsi (5).
+
+.SH SCSI ADAPTER TIPS
+
+The ISA-SCSI-adapters that are shipped with some UMAX-scanners are not supported very
+well by Linux (I suggest not to use it), the PCI-SCSI-adapters that come with some
+UMAX-scanners are not supported at all (as far as I know). On other platforms these
+SCSI-adapters are not supported. So you typically need to purchase another SCSI-adapter
+that is supported by your platform. See the relevant hardware FAQs and HOWTOs for your
+platform for more information.
+
+The UMAX-scanners do block the SCSI-bus for a few seconds while scanning. It is not
+necessary to connect the scanner to its own SCSI-adapter. But if you need short
+response time for your SCSI-harddisk (e.g. if your computer is a file-server) or
+other SCSI devices, I suggest you use an own SCSI-adapter for your UMAX-scanner.
+
+If you have any problems with your UMAX scanner, check your SCSI chain
+(cable length, termination, ...).
+
+See also:
+.BR sane\-scsi (5)
+
+.SH FILES
+
+.TP
+The backend configuration file:
+.I /etc/sane.d/umax.conf
+.TP
+The static library implementing this backend:
+.I /usr/lib64/sane/libsane\-umax.a
+.TP
+The shared library implementing this backend:
+.I /usr/lib64/sane/libsane\-umax.so
+(present on systems that support dynamic loading)
+
+.SH ENVIRONMENT
+
+.TP
+.B SANE_DEBUG_UMAX
+If the library was compiled with debug support enabled, this environment
+variable controls the debug level for this backend. E.g., a value of 128
+requests all debug output to be printed. Smaller levels reduce verbosity.
+.B SANE_DEBUG_UMAX
+values:
+
+.ft CR
+.nf
+Number Remark
+\
+ 0 print important errors (printed each time)
+ 1 print errors
+ 2 print sense
+ 3 print warnings
+ 4 print scanner-inquiry
+ 5 print information
+ 6 print less important information
+ 7 print called procedures
+ 8 print reader_process messages
+ 10 print called sane\-init-routines
+ 11 print called sane\-procedures
+ 12 print sane infos
+ 13 print sane option-control messages
+.fi
+.ft R
+
+.TP
+Example:
+export SANE_DEBUG_UMAX=8
+
+.SH BUGS
+X-resolutions greater than 600 dpi sometimes cause problems.
+
+.SH SEE ALSO
+.BR sane (7),
+.BR sane\-scsi (5)
+
+.SH AUTHOR
+Oliver Rauch
+
+.SH EMAIL-CONTACT
+.I Oliver.Rauch@Rauch-Domain.DE