summaryrefslogtreecommitdiffstats
path: root/upstream/opensuse-leap-15-6/man5/sane-artec.5
blob: 2f23e5b53553fca8b10b71a828df830481007375 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
.TH sane\-artec 5 "11 Jul 2008" "" "SANE Scanner Access Now Easy"
.IX sane\-artec

.SH NAME
sane\-artec \- SANE backend for Artec flatbed scanners

.SH DESCRIPTION
The
.B sane\-artec
library implements a SANE (Scanner Access Now Easy) backend
that provides access to Artec/Ultima SCSI flatbed scanners.  At present,
the following scanners are known to work at least partially with this backend:
.PP
.RS
* Artec A6000C
.br
* Artec A6000C PLUS
.br
* Artec ViewStation AT3
.br
* BlackWidow BW4800SP (rebadged Artec AT3)
.br
* Artec ViewStation AT6
.br
* Artec ViewStation AT12
.br
* Artec AM12S
.br
* Plustek 19200S (rebadged Artec AM12S)
.RE
.PP
Although this manual page is generally updated with each release,
up-to-date information on new releases and extraneous helpful hints
are available from the backend homepage:
.IR http://www4.infi.net/~cpinkham/sane .

.SH CONFIGURATION

The contents of the
.I artec.conf
file are a list of device names that
correspond to Artec scanners.  Empty lines and lines starting with a
hash mark (#) are ignored.  See
.BR sane\-scsi (5)
on details of what constitutes a valid device name.

Sample file:
.br
.nf
# artec.conf
#
# this is a comment.
#
# this line says search for any SCSI devices which are scanners and have
#     a vendor string of 'ULTIMA'
scsi ULTIMA
#
# the next line forces the backend to assume the next scanner found has
#     the specified vendor string (useful for testing rebadged models).
vendor ULTIMA
#
# the next line forces the backend to assume the next scanner found has
#     the specified model string (useful for testing rebadged models).
model AT3
#
# now a line that actually specifies a device.  The backend is going to
#     assume this is an Artec/Ultima AT3 because we forced the vendor and
#     model above.
/dev/scanner
#
# once we hit a scanner device line, the forced vendor and model
# string are
#     'forgotten', so the vendor and model for this next device will be
#     determined from the result of a SCSI inquiry.
/dev/sge
#
.fi

.SH SCSI ADAPTER TIPS

Some Artec scanners come with an included SCSI adapter.  If your scanner came
with a DTC ISA scsi cards, you can probably use it with recent (>= 2.2.0)
kernels using the generic NCR5380 support.  You must pass the following
boot argument to the kernel: "dtc3181e=0x2c0,0"
.br
I do not have any information on the PCI SCSI adapter included with some
newer Artec scanners.

.SH FILES
.TP
.I /etc/sane.d/artec.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
below).
.TP
.I /usr/lib64/sane/libsane\-artec.a
The static library implementing this backend.
.TP
.I /usr/lib64/sane/libsane\-artec.so
The shared library implementing this backend (present on systems that
support dynamic loading).

.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file.  Under UNIX, the directories are
separated by a colon (`:'), under OS/2, they are separated by a semi-
colon (`;').  If this variable is not set, the configuration file is
searched in two default directories: first, the current working direc-
tory (".") and then in
.IR /etc/sane.d .
If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories.  For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories
.IR tmp/config ,
.IR . ,
and
.I /etc/sane.d
being searched (in this order).
.TP
.B SANE_DEBUG_ARTEC
If the library was compiled with debug support enabled, this environment
variable controls the debug level for this backend. E.g., a value of 128
requests all debug output to be printed. Smaller levels reduce verbosity:
.B SANE_DEBUG_ARTEC
values:

.ft CR
.nf
Number  Remark
\
 0       print important errors
 1       print errors
 2       print sense
 3       print warnings
 4       print scanner-inquiry
 5       print information
 6       print less important information
 7       print major called procedures
 8       print all called procedures
 9       print procedure info/data messages
 10      print called sane\-init-routines
 11      print called sane\-procedures
 12      print sane infos
 13      print sane option-control messages
\
 50      print verbose data/debug messages
\
 == 100  print software RGB calibration data
 == 101  print raw data from scanner to artec.data.raw file
\
 == 128  print out all messages
.fi
.ft R
.PP
Example:
export SANE_DEBUG_ARTEC=13

.SH BUGS

Known bugs in this release: A6000C+ users with firmware v1.92 or
earlier have problems with the backend, the cause has not been determined.
Sometimes the backend is not particularly robust, you can possibly lock up
the SCSI bus (and/or machine) by not having patience enough when scanning.
3-channel gamma correction is not implemented and single-channel gamma
correction is not totally working on models other than the AT3.

.SH "SEE ALSO"
.BR sane (7) ,
.BR sane\-scsi (5)

.SH AUTHOR

Chris Pinkham
.I <cpinkham@corp.infi.net>