From f26f66d866ba1a9f3204e6fdfe2b07e67b5492ad Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Wed, 10 Apr 2024 21:41:32 +0200 Subject: Adding upstream version 2.8. Signed-off-by: Daniel Baumann --- Documentation/nvme-huawei-id-ctrl.html | 862 +++++++++++++++++++++++++++++++++ 1 file changed, 862 insertions(+) create mode 100644 Documentation/nvme-huawei-id-ctrl.html (limited to 'Documentation/nvme-huawei-id-ctrl.html') diff --git a/Documentation/nvme-huawei-id-ctrl.html b/Documentation/nvme-huawei-id-ctrl.html new file mode 100644 index 0000000..b04dd72 --- /dev/null +++ b/Documentation/nvme-huawei-id-ctrl.html @@ -0,0 +1,862 @@ + + + + + + +nvme-huawei-id-ctrl(1) + + + + + +
+
+

SYNOPSIS

+
+
+
nvme huawei id-ctrl <device> [--vendor-specific | -v] [--raw-binary | -b]
+                        [--output-format=<fmt> | -o <fmt>]
+
+
+
+
+
+

DESCRIPTION

+
+

For the NVMe device given, sends an identify controller command and +provides the result and returned structure.

+

The <device> parameter is mandatory and may be either the NVMe character +device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).

+

This will only work on Huawei devices supporting this feature. +Results for any other device are undefined.

+

On success, the structure may be returned in one of several ways depending +on the option flags; the structure may be parsed by the program or the +raw buffer may be printed to stdout.

+

If having the program decode the output for readability, this version +will decode Huawei vendor unique portions of the structure.

+
+
+
+

OPTIONS

+
+
+
+-b +
+
+--raw-binary +
+
+

+ Print the raw buffer to stdout. Structure is not parsed by + program. This overrides the vendor specific and human readable options. +

+
+
+-v +
+
+--vendor-specific +
+
+

+ In addition to parsing known fields, this option will dump + the vendor specific region of the structure in hex with ascii + interpretation. +

+
+
+-H +
+
+--human-readable +
+
+

+ This option will parse and format many of the bit fields + into human-readable formats. +

+
+
+-o <fmt> +
+
+--output-format=<fmt> +
+
+

+ Set the reporting format to normal, json, or + binary. Only one output format can be used at a time. +

+
+
+
+
+
+

EXAMPLES

+
+
    +
  • +

    +Has the program interpret the returned buffer and display the known +fields in a human readable format: +

    +
    +
    +
    # nvme huawei id-ctrl /dev/nvme0
    +
    +
  • +
+
+
+
+

NVME

+
+

Part of the nvme-user suite

+
+
+
+

+ + + -- cgit v1.2.3