summaryrefslogtreecommitdiffstats
path: root/daemons/execd/execd_commands.c
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-17 07:45:40 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-17 07:45:40 +0000
commit07d7f4cfa4b10de87a31b68191036ff446add675 (patch)
tree7162524d8aaf1aef62d2f4fa51f595ed113981ff /daemons/execd/execd_commands.c
parentAdding upstream version 2.1.6. (diff)
downloadpacemaker-upstream/2.1.7.tar.xz
pacemaker-upstream/2.1.7.zip
Adding upstream version 2.1.7.upstream/2.1.7
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'daemons/execd/execd_commands.c')
-rw-r--r--daemons/execd/execd_commands.c53
1 files changed, 32 insertions, 21 deletions
diff --git a/daemons/execd/execd_commands.c b/daemons/execd/execd_commands.c
index fa2761e..cf4503a 100644
--- a/daemons/execd/execd_commands.c
+++ b/daemons/execd/execd_commands.c
@@ -213,7 +213,7 @@ log_finished(const lrmd_cmd_t *cmd, int exec_time_ms, int queue_time_ms)
int log_level = LOG_INFO;
GString *str = g_string_sized_new(100); // reasonable starting size
- if (pcmk__str_eq(cmd->action, "monitor", pcmk__str_casei)) {
+ if (pcmk__str_eq(cmd->action, PCMK_ACTION_MONITOR, pcmk__str_casei)) {
log_level = LOG_DEBUG;
}
@@ -253,7 +253,7 @@ log_execute(lrmd_cmd_t * cmd)
{
int log_level = LOG_INFO;
- if (pcmk__str_eq(cmd->action, "monitor", pcmk__str_casei)) {
+ if (pcmk__str_eq(cmd->action, PCMK_ACTION_MONITOR, pcmk__str_casei)) {
log_level = LOG_DEBUG;
}
@@ -264,9 +264,9 @@ log_execute(lrmd_cmd_t * cmd)
static const char *
normalize_action_name(lrmd_rsc_t * rsc, const char *action)
{
- if (pcmk__str_eq(action, "monitor", pcmk__str_casei) &&
+ if (pcmk__str_eq(action, PCMK_ACTION_MONITOR, pcmk__str_casei) &&
pcmk_is_set(pcmk_get_ra_caps(rsc->class), pcmk_ra_cap_status)) {
- return "status";
+ return PCMK_ACTION_STATUS;
}
return action;
}
@@ -517,7 +517,7 @@ schedule_lrmd_cmd(lrmd_rsc_t * rsc, lrmd_cmd_t * cmd)
/* The controller expects the executor to automatically cancel
* recurring operations before a resource stops.
*/
- if (pcmk__str_eq(cmd->action, "stop", pcmk__str_casei)) {
+ if (pcmk__str_eq(cmd->action, PCMK_ACTION_STOP, pcmk__str_casei)) {
cancel_all_recurring(rsc, NULL);
}
@@ -844,7 +844,8 @@ action_complete(svc_action_t * action)
if (pcmk__str_eq(rclass, PCMK_RESOURCE_CLASS_SYSTEMD, pcmk__str_casei)) {
if (pcmk__result_ok(&(cmd->result))
- && pcmk__strcase_any_of(cmd->action, "start", "stop", NULL)) {
+ && pcmk__strcase_any_of(cmd->action, PCMK_ACTION_START,
+ PCMK_ACTION_STOP, NULL)) {
/* systemd returns from start and stop actions after the action
* begins, not after it completes. We have to jump through a few
* hoops so that we don't report 'complete' to the rest of pacemaker
@@ -852,7 +853,7 @@ action_complete(svc_action_t * action)
*/
goagain = true;
cmd->real_action = cmd->action;
- cmd->action = strdup("monitor");
+ cmd->action = strdup(PCMK_ACTION_MONITOR);
} else if (cmd->real_action != NULL) {
// This is follow-up monitor to check whether start/stop completed
@@ -860,7 +861,8 @@ action_complete(svc_action_t * action)
goagain = true;
} else if (pcmk__result_ok(&(cmd->result))
- && pcmk__str_eq(cmd->real_action, "stop", pcmk__str_casei)) {
+ && pcmk__str_eq(cmd->real_action, PCMK_ACTION_STOP,
+ pcmk__str_casei)) {
goagain = true;
} else {
@@ -878,9 +880,11 @@ action_complete(svc_action_t * action)
if ((cmd->result.execution_status == PCMK_EXEC_DONE)
&& (cmd->result.exit_status == PCMK_OCF_NOT_RUNNING)) {
- if (pcmk__str_eq(cmd->real_action, "start", pcmk__str_casei)) {
+ if (pcmk__str_eq(cmd->real_action, PCMK_ACTION_START,
+ pcmk__str_casei)) {
cmd->result.exit_status = PCMK_OCF_UNKNOWN_ERROR;
- } else if (pcmk__str_eq(cmd->real_action, "stop", pcmk__str_casei)) {
+ } else if (pcmk__str_eq(cmd->real_action, PCMK_ACTION_STOP,
+ pcmk__str_casei)) {
cmd->result.exit_status = PCMK_OCF_OK;
}
}
@@ -891,12 +895,12 @@ action_complete(svc_action_t * action)
#if SUPPORT_NAGIOS
if (rsc && pcmk__str_eq(rsc->class, PCMK_RESOURCE_CLASS_NAGIOS, pcmk__str_casei)) {
- if (action_matches(cmd, "monitor", 0)
+ if (action_matches(cmd, PCMK_ACTION_MONITOR, 0)
&& pcmk__result_ok(&(cmd->result))) {
/* Successfully executed --version for the nagios plugin */
cmd->result.exit_status = PCMK_OCF_NOT_RUNNING;
- } else if (pcmk__str_eq(cmd->action, "start", pcmk__str_casei)
+ } else if (pcmk__str_eq(cmd->action, PCMK_ACTION_START, pcmk__str_casei)
&& !pcmk__result_ok(&(cmd->result))) {
#ifdef PCMK__TIME_USE_CGT
goagain = true;
@@ -1007,11 +1011,11 @@ stonith_action_complete(lrmd_cmd_t *cmd, int exit_status,
/* This should be possible only for probes in practice, but
* interpret for all actions to be safe.
*/
- if (pcmk__str_eq(cmd->action, CRMD_ACTION_STATUS,
+ if (pcmk__str_eq(cmd->action, PCMK_ACTION_MONITOR,
pcmk__str_none)) {
exit_status = PCMK_OCF_NOT_RUNNING;
- } else if (pcmk__str_eq(cmd->action, CRMD_ACTION_STOP,
+ } else if (pcmk__str_eq(cmd->action, PCMK_ACTION_STOP,
pcmk__str_none)) {
exit_status = PCMK_OCF_OK;
@@ -1035,11 +1039,12 @@ stonith_action_complete(lrmd_cmd_t *cmd, int exit_status,
// Certain successful actions change the known state of the resource
if ((rsc != NULL) && pcmk__result_ok(&(cmd->result))) {
- if (pcmk__str_eq(cmd->action, "start", pcmk__str_casei)) {
+ if (pcmk__str_eq(cmd->action, PCMK_ACTION_START, pcmk__str_casei)) {
pcmk__set_result(&rsc->fence_probe_result, CRM_EX_OK,
PCMK_EXEC_DONE, NULL); // "running"
- } else if (pcmk__str_eq(cmd->action, "stop", pcmk__str_casei)) {
+ } else if (pcmk__str_eq(cmd->action, PCMK_ACTION_STOP,
+ pcmk__str_casei)) {
pcmk__set_result(&rsc->fence_probe_result, CRM_EX_ERROR,
PCMK_EXEC_NO_FENCE_DEVICE, NULL); // "not running"
}
@@ -1235,7 +1240,7 @@ execute_stonith_action(lrmd_rsc_t *rsc, lrmd_cmd_t *cmd)
stonith_t *stonith_api = get_stonith_connection();
- if (pcmk__str_eq(cmd->action, "monitor", pcmk__str_casei)
+ if (pcmk__str_eq(cmd->action, PCMK_ACTION_MONITOR, pcmk__str_casei)
&& (cmd->interval_ms == 0)) {
// Probes don't require a fencer connection
stonith_action_complete(cmd, rsc->fence_probe_result.exit_status,
@@ -1249,16 +1254,17 @@ execute_stonith_action(lrmd_rsc_t *rsc, lrmd_cmd_t *cmd)
"No connection to fencer");
return;
- } else if (pcmk__str_eq(cmd->action, "start", pcmk__str_casei)) {
+ } else if (pcmk__str_eq(cmd->action, PCMK_ACTION_START, pcmk__str_casei)) {
rc = execd_stonith_start(stonith_api, rsc, cmd);
if (rc == pcmk_ok) {
do_monitor = TRUE;
}
- } else if (pcmk__str_eq(cmd->action, "stop", pcmk__str_casei)) {
+ } else if (pcmk__str_eq(cmd->action, PCMK_ACTION_STOP, pcmk__str_casei)) {
rc = execd_stonith_stop(stonith_api, rsc);
- } else if (pcmk__str_eq(cmd->action, "monitor", pcmk__str_casei)) {
+ } else if (pcmk__str_eq(cmd->action, PCMK_ACTION_MONITOR,
+ pcmk__str_casei)) {
do_monitor = TRUE;
} else {
@@ -1297,7 +1303,7 @@ execute_nonstonith_action(lrmd_rsc_t *rsc, lrmd_cmd_t *cmd)
#if SUPPORT_NAGIOS
/* Recurring operations are cancelled anyway for a stop operation */
if (pcmk__str_eq(rsc->class, PCMK_RESOURCE_CLASS_NAGIOS, pcmk__str_casei)
- && pcmk__str_eq(cmd->action, "stop", pcmk__str_casei)) {
+ && pcmk__str_eq(cmd->action, PCMK_ACTION_STOP, pcmk__str_casei)) {
cmd->result.exit_status = PCMK_OCF_OK;
cmd_finalize(cmd, rsc);
@@ -1474,6 +1480,7 @@ process_lrmd_signon(pcmk__client_t *client, xmlNode *request, int call_id,
int rc = pcmk_ok;
time_t now = time(NULL);
const char *protocol_version = crm_element_value(request, F_LRMD_PROTOCOL_VERSION);
+ const char *start_state = pcmk__env_option(PCMK__ENV_NODE_START_STATE);
if (compare_version(protocol_version, LRMD_MIN_PROTOCOL_VERSION) < 0) {
crm_err("Cluster API version must be greater than or equal to %s, not %s",
@@ -1503,6 +1510,10 @@ process_lrmd_signon(pcmk__client_t *client, xmlNode *request, int call_id,
crm_xml_add(*reply, F_LRMD_PROTOCOL_VERSION, LRMD_PROTOCOL_VERSION);
crm_xml_add_ll(*reply, PCMK__XA_UPTIME, now - start_time);
+ if (start_state) {
+ crm_xml_add(*reply, PCMK__XA_NODE_START_STATE, start_state);
+ }
+
return rc;
}