=#=#=#= Begin test: Get CIB manager metadata =#=#=#= 1.1 Cluster options used by Pacemaker's Cluster Information Base manager Cluster Information Base manager options Enable Access Control Lists (ACLs) for the CIB Enable Access Control Lists (ACLs) for the CIB Raise this if log has "Evicting client" messages for cluster daemon PIDs (a good value is the number of resources in the cluster multiplied by the number of nodes). Maximum IPC message backlog before disconnecting a cluster daemon =#=#=#= End test: Get CIB manager metadata - OK (0) =#=#=#= * Passed: pacemaker-based - Get CIB manager metadata =#=#=#= Begin test: Get controller metadata =#=#=#= 1.1 Cluster options used by Pacemaker's controller Pacemaker controller options Includes a hash which identifies the exact changeset the code was built from. Used for diagnostic purposes. Pacemaker version on cluster node elected Designated Controller (DC) Used for informational and diagnostic purposes. The messaging stack on which Pacemaker is currently running This optional value is mostly for users' convenience as desired in administration, but may also be used in Pacemaker configuration rules via the #cluster-name node attribute, and by higher-level tools and resource agents. An arbitrary name for the cluster The optimal value will depend on the speed and load of your network and the type of switches used. How long to wait for a response from other nodes during start-up Pacemaker is primarily event-driven, and looks ahead to know when to recheck cluster state for failure timeouts and most time-based rules. However, it will also recheck the cluster after this amount of inactivity, to evaluate rules with date specifications and serve as a fail-safe for certain types of scheduler bugs. Allowed values: Zero disables polling, while positive values are an interval in seconds(unless other units are specified, for example "5min") Polling interval to recheck cluster state and evaluate rules with date specifications The cluster will slow down its recovery process when the amount of system resources used (currently CPU) approaches this limit Maximum amount of system load that should be used by cluster nodes Maximum number of jobs that can be scheduled per node (defaults to 2x cores) Maximum number of jobs that can be scheduled per node (defaults to 2x cores) A cluster node may receive notification of its own fencing if fencing is misconfigured, or if fabric fencing is in use that doesn't cut cluster communication. Allowed values are "stop" to attempt to immediately stop Pacemaker and stay stopped, or "panic" to attempt to immediately reboot the local node, falling back to stop on failure. How a cluster node should react if notified of its own fencing Declare an election failed if it is not decided within this much time. If you need to adjust this value, it probably indicates the presence of a bug. *** Advanced Use Only *** Exit immediately if shutdown does not complete within this much time. If you need to adjust this value, it probably indicates the presence of a bug. *** Advanced Use Only *** If you need to adjust this value, it probably indicates the presence of a bug. *** Advanced Use Only *** If you need to adjust this value, it probably indicates the presence of a bug. *** Advanced Use Only *** Delay cluster recovery for this much time to allow for additional events to occur. Useful if your configuration is sensitive to the order in which ping updates arrive. *** Advanced Use Only *** Enabling this option will slow down cluster recovery under all conditions If this is set to a positive value, lost nodes are assumed to self-fence using watchdog-based SBD within this much time. This does not require a fencing resource to be explicitly configured, though a fence_watchdog resource can be configured, to limit use to specific nodes. If this is set to 0 (the default), the cluster will never assume watchdog-based self-fencing. If this is set to a negative value, the cluster will use twice the local value of the `SBD_WATCHDOG_TIMEOUT` environment variable if that is positive, or otherwise treat this as 0. WARNING: When used, this timeout must be larger than `SBD_WATCHDOG_TIMEOUT` on all nodes that use watchdog-based SBD, and Pacemaker will refuse to start on any of those nodes where this is not true for the local value or SBD is not active. When this is set to a negative value, `SBD_WATCHDOG_TIMEOUT` must be set to the same value on all nodes that use SBD, otherwise data corruption or loss could occur. How long before nodes can be assumed to be safely down when watchdog-based self-fencing via SBD is in use How many times fencing can fail before it will no longer be immediately re-attempted on a target How many times fencing can fail before it will no longer be immediately re-attempted on a target What to do when the cluster does not have quorum Allowed values: stop, freeze, ignore, demote, suicide What to do when the cluster does not have quorum When true, resources active on a node when it is cleanly shut down are kept "locked" to that node (not allowed to run elsewhere) until they start again on that node after it rejoins (or for at most shutdown-lock-limit, if set). Stonith resources and Pacemaker Remote connections are never locked. Clone and bundle instances and the promoted role of promotable clones are currently never locked, though support could be added in a future release. Whether to lock resources to a cleanly shut down node If shutdown-lock is true and this is set to a nonzero time duration, shutdown locks will expire after this much time has passed since the shutdown was initiated, even if the node has not rejoined. Do not lock resources to a cleanly shut down node longer than this =#=#=#= End test: Get controller metadata - OK (0) =#=#=#= * Passed: pacemaker-controld - Get controller metadata =#=#=#= Begin test: Get fencer metadata =#=#=#= 1.1 Instance attributes available for all "stonith"-class resources and used by Pacemaker's fence daemon, formerly known as stonithd Instance attributes available for all "stonith"-class resources some devices do not support the standard 'port' parameter or may provide additional ones. Use this to specify an alternate, device-specific, parameter that should indicate the machine to be fenced. A value of none can be used to tell the cluster not to supply any additional parameters. Advanced use only: An alternate parameter to supply instead of 'port' Eg. node1:1;node2:2,3 would tell the cluster to use port 1 for node1 and ports 2 and 3 for node2 A mapping of host names to ports numbers for devices that do not support host names. A list of machines controlled by this device (Optional unless pcmk_host_list=static-list) Eg. node1,node2,node3 Allowed values: dynamic-list (query the device via the 'list' command), static-list (check the pcmk_host_list attribute), status (query the device via the 'status' command), none (assume every device can fence every machine) How to determine which machines are controlled by the device. Enable a delay of no more than the time specified before executing fencing actions. Pacemaker derives the overall delay by taking the value of pcmk_delay_base and adding a random delay value such that the sum is kept below this maximum. Enable a base delay for fencing actions and specify base delay value. This enables a static delay for fencing actions, which can help avoid "death matches" where two nodes try to fence each other at the same time. If pcmk_delay_max is also used, a random delay will be added such that the total delay is kept below that value.This can be set to a single time value to apply to any node targeted by this device (useful if a separate device is configured for each target), or to a node map (for example, "node1:1s;node2:5") to set a different value per target. Enable a base delay for fencing actions and specify base delay value. Cluster property concurrent-fencing=true needs to be configured first.Then use this to specify the maximum number of actions can be performed in parallel on this device. -1 is unlimited. The maximum number of actions can be performed in parallel on this device Some devices do not support the standard commands or may provide additional ones.\nUse this to specify an alternate, device-specific, command that implements the 'reboot' action. Advanced use only: An alternate command to run instead of 'reboot' Some devices need much more/less time to complete than normal.Use this to specify an alternate, device-specific, timeout for 'reboot' actions. Advanced use only: Specify an alternate timeout to use for reboot actions instead of stonith-timeout Some devices do not support multiple connections. Operations may 'fail' if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries 'reboot' actions before giving up. Advanced use only: The maximum number of times to retry the 'reboot' command within the timeout period Some devices do not support the standard commands or may provide additional ones.Use this to specify an alternate, device-specific, command that implements the 'off' action. Advanced use only: An alternate command to run instead of 'off' Some devices need much more/less time to complete than normal.Use this to specify an alternate, device-specific, timeout for 'off' actions. Advanced use only: Specify an alternate timeout to use for off actions instead of stonith-timeout Some devices do not support multiple connections. Operations may 'fail' if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries 'off' actions before giving up. Advanced use only: The maximum number of times to retry the 'off' command within the timeout period Some devices do not support the standard commands or may provide additional ones.Use this to specify an alternate, device-specific, command that implements the 'on' action. Advanced use only: An alternate command to run instead of 'on' Some devices need much more/less time to complete than normal.Use this to specify an alternate, device-specific, timeout for 'on' actions. Advanced use only: Specify an alternate timeout to use for on actions instead of stonith-timeout Some devices do not support multiple connections. Operations may 'fail' if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries 'on' actions before giving up. Advanced use only: The maximum number of times to retry the 'on' command within the timeout period Some devices do not support the standard commands or may provide additional ones.Use this to specify an alternate, device-specific, command that implements the 'list' action. Advanced use only: An alternate command to run instead of 'list' Some devices need much more/less time to complete than normal.Use this to specify an alternate, device-specific, timeout for 'list' actions. Advanced use only: Specify an alternate timeout to use for list actions instead of stonith-timeout Some devices do not support multiple connections. Operations may 'fail' if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries 'list' actions before giving up. Advanced use only: The maximum number of times to retry the 'list' command within the timeout period Some devices do not support the standard commands or may provide additional ones.Use this to specify an alternate, device-specific, command that implements the 'monitor' action. Advanced use only: An alternate command to run instead of 'monitor' Some devices need much more/less time to complete than normal.\nUse this to specify an alternate, device-specific, timeout for 'monitor' actions. Advanced use only: Specify an alternate timeout to use for monitor actions instead of stonith-timeout Some devices do not support multiple connections. Operations may 'fail' if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries 'monitor' actions before giving up. Advanced use only: The maximum number of times to retry the 'monitor' command within the timeout period Some devices do not support the standard commands or may provide additional ones.Use this to specify an alternate, device-specific, command that implements the 'status' action. Advanced use only: An alternate command to run instead of 'status' Some devices need much more/less time to complete than normal.Use this to specify an alternate, device-specific, timeout for 'status' actions. Advanced use only: Specify an alternate timeout to use for status actions instead of stonith-timeout Some devices do not support multiple connections. Operations may 'fail' if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries 'status' actions before giving up. Advanced use only: The maximum number of times to retry the 'status' command within the timeout period =#=#=#= End test: Get fencer metadata - OK (0) =#=#=#= * Passed: pacemaker-fenced - Get fencer metadata =#=#=#= Begin test: Get scheduler metadata =#=#=#= 1.1 Cluster options used by Pacemaker's scheduler Pacemaker scheduler options What to do when the cluster does not have quorum Allowed values: stop, freeze, ignore, demote, suicide What to do when the cluster does not have quorum Whether resources can run on any node by default Whether resources can run on any node by default Whether the cluster should refrain from monitoring, starting, and stopping resources Whether the cluster should refrain from monitoring, starting, and stopping resources When true, the cluster will immediately ban a resource from a node if it fails to start there. When false, the cluster will instead check the resource's fail count against its migration-threshold. Whether a start failure should prevent a resource from being recovered on the same node Whether the cluster should check for active resources during start-up Whether the cluster should check for active resources during start-up When true, resources active on a node when it is cleanly shut down are kept "locked" to that node (not allowed to run elsewhere) until they start again on that node after it rejoins (or for at most shutdown-lock-limit, if set). Stonith resources and Pacemaker Remote connections are never locked. Clone and bundle instances and the promoted role of promotable clones are currently never locked, though support could be added in a future release. Whether to lock resources to a cleanly shut down node If shutdown-lock is true and this is set to a nonzero time duration, shutdown locks will expire after this much time has passed since the shutdown was initiated, even if the node has not rejoined. Do not lock resources to a cleanly shut down node longer than this If false, unresponsive nodes are immediately assumed to be harmless, and resources that were active on them may be recovered elsewhere. This can result in a "split-brain" situation, potentially leading to data loss and/or service unavailability. *** Advanced Use Only *** Whether nodes may be fenced as part of recovery Action to send to fence device when a node needs to be fenced ("poweroff" is a deprecated alias for "off") Allowed values: reboot, off, poweroff Action to send to fence device when a node needs to be fenced ("poweroff" is a deprecated alias for "off") This value is not used by Pacemaker, but is kept for backward compatibility, and certain legacy fence agents might use it. *** Advanced Use Only *** Unused by Pacemaker This is set automatically by the cluster according to whether SBD is detected to be in use. User-configured values are ignored. The value `true` is meaningful if diskless SBD is used and `stonith-watchdog-timeout` is nonzero. In that case, if fencing is required, watchdog-based self-fencing will be performed via SBD without requiring a fencing resource explicitly configured. Whether watchdog integration is enabled Allow performing fencing operations in parallel Allow performing fencing operations in parallel Setting this to false may lead to a "split-brain" situation,potentially leading to data loss and/or service unavailability. *** Advanced Use Only *** Whether to fence unseen nodes at start-up Apply specified delay for the fencings that are targeting the lost nodes with the highest total resource priority in case we don't have the majority of the nodes in our cluster partition, so that the more significant nodes potentially win any fencing match, which is especially meaningful under split-brain of 2-node cluster. A promoted resource instance takes the base priority + 1 on calculation if the base priority is not 0. Any static/random delays that are introduced by `pcmk_delay_base/max` configured for the corresponding fencing resources will be added to this delay. This delay should be significantly greater than, safely twice, the maximum `pcmk_delay_base/max`. By default, priority fencing delay is disabled. Apply fencing delay targeting the lost nodes with the highest total resource priority The node elected Designated Controller (DC) will consider an action failed if it does not get a response from the node executing the action within this time (after considering the action's own timeout). The "correct" value will depend on the speed and load of your network and cluster nodes. Maximum time for node-to-node communication The "correct" value will depend on the speed and load of your network and cluster nodes. If set to 0, the cluster will impose a dynamically calculated limit when any node has a high load. Maximum number of jobs that the cluster may execute in parallel across all nodes The number of live migration actions that the cluster is allowed to execute in parallel on a node (-1 means no limit) The number of live migration actions that the cluster is allowed to execute in parallel on a node (-1 means no limit) Whether the cluster should stop all active resources Whether the cluster should stop all active resources Whether to stop resources that were removed from the configuration Whether to stop resources that were removed from the configuration Whether to cancel recurring actions removed from the configuration Whether to cancel recurring actions removed from the configuration Values other than default are poorly tested and potentially dangerous. This option will be removed in a future release. *** Deprecated *** Whether to remove stopped resources from the executor Zero to disable, -1 to store unlimited. The number of scheduler inputs resulting in errors to save Zero to disable, -1 to store unlimited. The number of scheduler inputs resulting in warnings to save Zero to disable, -1 to store unlimited. The number of scheduler inputs without errors or warnings to save Requires external entities to create node attributes (named with the prefix "#health") with values "red", "yellow", or "green". Allowed values: none, migrate-on-red, only-green, progressive, custom How cluster should react to node health attributes Only used when "node-health-strategy" is set to "progressive". Base health score assigned to a node Only used when "node-health-strategy" is set to "custom" or "progressive". The score to use for a node health attribute whose value is "green" Only used when "node-health-strategy" is set to "custom" or "progressive". The score to use for a node health attribute whose value is "yellow" Only used when "node-health-strategy" is set to "custom" or "progressive". The score to use for a node health attribute whose value is "red" How the cluster should allocate resources to nodes Allowed values: default, utilization, minimal, balanced How the cluster should allocate resources to nodes =#=#=#= End test: Get scheduler metadata - OK (0) =#=#=#= * Passed: pacemaker-schedulerd - Get scheduler metadata