1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
|
=#=#=#= Begin test: Get CIB manager metadata =#=#=#=
<resource-agent name="pacemaker-based" version="">
<version>
1.1
</version>
<longdesc lang="en">
Cluster options used by Pacemaker's Cluster Information Base manager
</longdesc>
<shortdesc lang="en">
Cluster Information Base manager options
</shortdesc>
<parameters>
<parameter name="enable-acl">
<longdesc lang="en">
Enable Access Control Lists (ACLs) for the CIB
</longdesc>
<shortdesc lang="en">
Enable Access Control Lists (ACLs) for the CIB
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="cluster-ipc-limit">
<longdesc lang="en">
Raise this if log has "Evicting client" messages for cluster daemon PIDs (a good value is the number of resources in the cluster multiplied by the number of nodes).
</longdesc>
<shortdesc lang="en">
Maximum IPC message backlog before disconnecting a cluster daemon
</shortdesc>
<content type="integer" default=""/>
</parameter>
</parameters>
</resource-agent>
=#=#=#= End test: Get CIB manager metadata - OK (0) =#=#=#=
* Passed: pacemaker-based - Get CIB manager metadata
=#=#=#= Begin test: Get controller metadata =#=#=#=
<resource-agent name="pacemaker-controld" version="">
<version>
1.1
</version>
<longdesc lang="en">
Cluster options used by Pacemaker's controller
</longdesc>
<shortdesc lang="en">
Pacemaker controller options
</shortdesc>
<parameters>
<parameter name="dc-version">
<longdesc lang="en">
Includes a hash which identifies the exact revision the code was built from. Used for diagnostic purposes.
</longdesc>
<shortdesc lang="en">
Pacemaker version on cluster node elected Designated Controller (DC)
</shortdesc>
<content type="string"/>
</parameter>
<parameter name="cluster-infrastructure">
<longdesc lang="en">
Used for informational and diagnostic purposes.
</longdesc>
<shortdesc lang="en">
The messaging layer on which Pacemaker is currently running
</shortdesc>
<content type="string"/>
</parameter>
<parameter name="cluster-name">
<longdesc lang="en">
This optional value is mostly for users' convenience as desired in administration, but may also be used in Pacemaker configuration rules via the #cluster-name node attribute, and by higher-level tools and resource agents.
</longdesc>
<shortdesc lang="en">
An arbitrary name for the cluster
</shortdesc>
<content type="string"/>
</parameter>
<parameter name="dc-deadtime">
<longdesc lang="en">
The optimal value will depend on the speed and load of your network and the type of switches used.
</longdesc>
<shortdesc lang="en">
How long to wait for a response from other nodes during start-up
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="cluster-recheck-interval">
<longdesc lang="en">
Pacemaker is primarily event-driven, and looks ahead to know when to recheck cluster state for failure-timeout settings and most time-based rules. However, it will also recheck the cluster after this amount of inactivity, to evaluate rules with date specifications and serve as a fail-safe for certain types of scheduler bugs. A value of 0 disables polling. A positive value sets an interval in seconds, unless other units are specified (for example, "5min").
</longdesc>
<shortdesc lang="en">
Polling interval to recheck cluster state and evaluate rules with date specifications
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="fence-reaction">
<longdesc lang="en">
A cluster node may receive notification of a "succeeded" fencing that targeted it if fencing is misconfigured, or if fabric fencing is in use that doesn't cut cluster communication. Use "stop" to attempt to immediately stop Pacemaker and stay stopped, or "panic" to attempt to immediately reboot the local node, falling back to stop on failure. Allowed values: stop, panic
</longdesc>
<shortdesc lang="en">
How a cluster node should react if notified of its own fencing
</shortdesc>
<content type="select" default="">
<option value="stop"/>
<option value="panic"/>
</content>
</parameter>
<parameter name="election-timeout">
<longdesc lang="en">
Declare an election failed if it is not decided within this much time. If you need to adjust this value, it probably indicates the presence of a bug.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only ***
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="shutdown-escalation">
<longdesc lang="en">
Exit immediately if shutdown does not complete within this much time. If you need to adjust this value, it probably indicates the presence of a bug.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only ***
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="join-integration-timeout">
<longdesc lang="en">
If you need to adjust this value, it probably indicates the presence of a bug.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only ***
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="join-finalization-timeout">
<longdesc lang="en">
If you need to adjust this value, it probably indicates the presence of a bug.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only ***
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="transition-delay">
<longdesc lang="en">
Delay cluster recovery for this much time to allow for additional events to occur. Useful if your configuration is sensitive to the order in which ping updates arrive.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Enabling this option will slow down cluster recovery under all conditions
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="stonith-watchdog-timeout">
<longdesc lang="en">
If this is set to a positive value, lost nodes are assumed to achieve self-fencing using watchdog-based SBD within this much time. This does not require a fencing resource to be explicitly configured, though a fence_watchdog resource can be configured, to limit use to specific nodes. If this is set to 0 (the default), the cluster will never assume watchdog-based self-fencing. If this is set to a negative value, the cluster will use twice the local value of the `SBD_WATCHDOG_TIMEOUT` environment variable if that is positive, or otherwise treat this as 0. WARNING: When used, this timeout must be larger than `SBD_WATCHDOG_TIMEOUT` on all nodes that use watchdog-based SBD, and Pacemaker will refuse to start on any of those nodes where this is not true for the local value or SBD is not active. When this is set to a negative value, `SBD_WATCHDOG_TIMEOUT` must be set to the same value on all nodes that use SBD, otherwise data corruption or loss could occur.
</longdesc>
<shortdesc lang="en">
How long before nodes can be assumed to be safely down when watchdog-based self-fencing via SBD is in use
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="stonith-max-attempts">
<longdesc lang="en">
How many times fencing can fail before it will no longer be immediately re-attempted on a target
</longdesc>
<shortdesc lang="en">
How many times fencing can fail before it will no longer be immediately re-attempted on a target
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="load-threshold">
<longdesc lang="en">
The cluster will slow down its recovery process when the amount of system resources used (currently CPU) approaches this limit
</longdesc>
<shortdesc lang="en">
Maximum amount of system load that should be used by cluster nodes
</shortdesc>
<content type="percentage" default=""/>
</parameter>
<parameter name="node-action-limit">
<longdesc lang="en">
Maximum number of jobs that can be scheduled per node (defaults to 2x cores)
</longdesc>
<shortdesc lang="en">
Maximum number of jobs that can be scheduled per node (defaults to 2x cores)
</shortdesc>
<content type="integer" default=""/>
</parameter>
</parameters>
</resource-agent>
=#=#=#= End test: Get controller metadata - OK (0) =#=#=#=
* Passed: pacemaker-controld - Get controller metadata
=#=#=#= Begin test: Get fencer metadata =#=#=#=
<resource-agent name="pacemaker-fenced" version="">
<version>
1.1
</version>
<longdesc lang="en">
Instance attributes available for all "stonith"-class resources and used by Pacemaker's fence daemon, formerly known as stonithd
</longdesc>
<shortdesc lang="en">
Instance attributes available for all "stonith"-class resources
</shortdesc>
<parameters>
<parameter name="pcmk_host_argument">
<longdesc lang="en">
Some devices do not support the standard 'port' parameter or may provide additional ones. Use this to specify an alternate, device-specific, parameter that should indicate the machine to be fenced. A value of "none" can be used to tell the cluster not to supply any additional parameters.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** An alternate parameter to supply instead of 'port'
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_host_map">
<longdesc lang="en">
For example, "node1:1;node2:2,3" would tell the cluster to use port 1 for node1 and ports 2 and 3 for node2.
</longdesc>
<shortdesc lang="en">
A mapping of node names to port numbers for devices that do not support node names.
</shortdesc>
<content type="string"/>
</parameter>
<parameter name="pcmk_host_list">
<longdesc lang="en">
Comma-separated list of nodes that can be targeted by this device (for example, "node1,node2,node3"). If pcmk_host_check is "static-list", either this or pcmk_host_map must be set.
</longdesc>
<shortdesc lang="en">
Nodes targeted by this device
</shortdesc>
<content type="string"/>
</parameter>
<parameter name="pcmk_host_check">
<longdesc lang="en">
Use "dynamic-list" to query the device via the 'list' command; "static-list" to check the pcmk_host_list attribute; "status" to query the device via the 'status' command; or "none" to assume every device can fence every node. The default value is "static-list" if pcmk_host_map or pcmk_host_list is set; otherwise "dynamic-list" if the device supports the list operation; otherwise "status" if the device supports the status operation; otherwise "none" Allowed values: dynamic-list, static-list, status, none
</longdesc>
<shortdesc lang="en">
How to determine which nodes can be targeted by the device
</shortdesc>
<content type="select">
<option value="dynamic-list"/>
<option value="static-list"/>
<option value="status"/>
<option value="none"/>
</content>
</parameter>
<parameter name="pcmk_delay_max">
<longdesc lang="en">
Enable a delay of no more than the time specified before executing fencing actions. Pacemaker derives the overall delay by taking the value of pcmk_delay_base and adding a random delay value such that the sum is kept below this maximum.
</longdesc>
<shortdesc lang="en">
Enable a delay of no more than the time specified before executing fencing actions.
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="pcmk_delay_base">
<longdesc lang="en">
This enables a static delay for fencing actions, which can help avoid "death matches" where two nodes try to fence each other at the same time. If pcmk_delay_max is also used, a random delay will be added such that the total delay is kept below that value. This can be set to a single time value to apply to any node targeted by this device (useful if a separate device is configured for each target), or to a node map (for example, "node1:1s;node2:5") to set a different value for each target.
</longdesc>
<shortdesc lang="en">
Enable a base delay for fencing actions and specify base delay value.
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_action_limit">
<longdesc lang="en">
Cluster property concurrent-fencing="true" needs to be configured first. Then use this to specify the maximum number of actions can be performed in parallel on this device. A value of -1 means an unlimited number of actions can be performed in parallel.
</longdesc>
<shortdesc lang="en">
The maximum number of actions can be performed in parallel on this device
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pcmk_reboot_action">
<longdesc lang="en">
Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the 'reboot' action.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** An alternate command to run instead of 'reboot'
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_reboot_timeout">
<longdesc lang="en">
Some devices need much more/less time to complete than normal. Use this to specify an alternate, device-specific, timeout for 'reboot' actions.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Specify an alternate timeout to use for 'reboot' actions instead of stonith-timeout
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="pcmk_reboot_retries">
<longdesc lang="en">
Some devices do not support multiple connections. Operations may "fail" if the device is busy with another task. In that case, Pacemaker will automatically retry the operation if there is time remaining. Use this option to alter the number of times Pacemaker tries a 'reboot' action before giving up.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** The maximum number of times to try the 'reboot' command within the timeout period
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pcmk_off_action">
<longdesc lang="en">
Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the 'off' action.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** An alternate command to run instead of 'off'
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_off_timeout">
<longdesc lang="en">
Some devices need much more/less time to complete than normal. Use this to specify an alternate, device-specific, timeout for 'off' actions.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Specify an alternate timeout to use for 'off' actions instead of stonith-timeout
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="pcmk_off_retries">
<longdesc lang="en">
Some devices do not support multiple connections. Operations may "fail" if the device is busy with another task. In that case, Pacemaker will automatically retry the operation if there is time remaining. Use this option to alter the number of times Pacemaker tries a 'off' action before giving up.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** The maximum number of times to try the 'off' command within the timeout period
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pcmk_on_action">
<longdesc lang="en">
Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the 'on' action.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** An alternate command to run instead of 'on'
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_on_timeout">
<longdesc lang="en">
Some devices need much more/less time to complete than normal. Use this to specify an alternate, device-specific, timeout for 'on' actions.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Specify an alternate timeout to use for 'on' actions instead of stonith-timeout
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="pcmk_on_retries">
<longdesc lang="en">
Some devices do not support multiple connections. Operations may "fail" if the device is busy with another task. In that case, Pacemaker will automatically retry the operation if there is time remaining. Use this option to alter the number of times Pacemaker tries a 'on' action before giving up.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** The maximum number of times to try the 'on' command within the timeout period
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pcmk_list_action">
<longdesc lang="en">
Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the 'list' action.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** An alternate command to run instead of 'list'
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_list_timeout">
<longdesc lang="en">
Some devices need much more/less time to complete than normal. Use this to specify an alternate, device-specific, timeout for 'list' actions.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Specify an alternate timeout to use for 'list' actions instead of stonith-timeout
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="pcmk_list_retries">
<longdesc lang="en">
Some devices do not support multiple connections. Operations may "fail" if the device is busy with another task. In that case, Pacemaker will automatically retry the operation if there is time remaining. Use this option to alter the number of times Pacemaker tries a 'list' action before giving up.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** The maximum number of times to try the 'list' command within the timeout period
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pcmk_monitor_action">
<longdesc lang="en">
Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the 'monitor' action.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** An alternate command to run instead of 'monitor'
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_monitor_timeout">
<longdesc lang="en">
Some devices need much more/less time to complete than normal. Use this to specify an alternate, device-specific, timeout for 'monitor' actions.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Specify an alternate timeout to use for 'monitor' actions instead of stonith-timeout
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="pcmk_monitor_retries">
<longdesc lang="en">
Some devices do not support multiple connections. Operations may "fail" if the device is busy with another task. In that case, Pacemaker will automatically retry the operation if there is time remaining. Use this option to alter the number of times Pacemaker tries a 'monitor' action before giving up.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** The maximum number of times to try the 'monitor' command within the timeout period
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pcmk_status_action">
<longdesc lang="en">
Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the 'status' action.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** An alternate command to run instead of 'status'
</shortdesc>
<content type="string" default=""/>
</parameter>
<parameter name="pcmk_status_timeout">
<longdesc lang="en">
Some devices need much more/less time to complete than normal. Use this to specify an alternate, device-specific, timeout for 'status' actions.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Specify an alternate timeout to use for 'status' actions instead of stonith-timeout
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="pcmk_status_retries">
<longdesc lang="en">
Some devices do not support multiple connections. Operations may "fail" if the device is busy with another task. In that case, Pacemaker will automatically retry the operation if there is time remaining. Use this option to alter the number of times Pacemaker tries a 'status' action before giving up.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** The maximum number of times to try the 'status' command within the timeout period
</shortdesc>
<content type="integer" default=""/>
</parameter>
</parameters>
</resource-agent>
=#=#=#= End test: Get fencer metadata - OK (0) =#=#=#=
* Passed: pacemaker-fenced - Get fencer metadata
=#=#=#= Begin test: Get scheduler metadata =#=#=#=
<resource-agent name="pacemaker-schedulerd" version="">
<version>
1.1
</version>
<longdesc lang="en">
Cluster options used by Pacemaker's scheduler
</longdesc>
<shortdesc lang="en">
Pacemaker scheduler options
</shortdesc>
<parameters>
<parameter name="no-quorum-policy">
<longdesc lang="en">
What to do when the cluster does not have quorum Allowed values: stop, freeze, ignore, demote, suicide
</longdesc>
<shortdesc lang="en">
What to do when the cluster does not have quorum
</shortdesc>
<content type="select" default="">
<option value="stop"/>
<option value="freeze"/>
<option value="ignore"/>
<option value="demote"/>
<option value="suicide"/>
</content>
</parameter>
<parameter name="shutdown-lock">
<longdesc lang="en">
When true, resources active on a node when it is cleanly shut down are kept "locked" to that node (not allowed to run elsewhere) until they start again on that node after it rejoins (or for at most shutdown-lock-limit, if set). Stonith resources and Pacemaker Remote connections are never locked. Clone and bundle instances and the promoted role of promotable clones are currently never locked, though support could be added in a future release.
</longdesc>
<shortdesc lang="en">
Whether to lock resources to a cleanly shut down node
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="shutdown-lock-limit">
<longdesc lang="en">
If shutdown-lock is true and this is set to a nonzero time duration, shutdown locks will expire after this much time has passed since the shutdown was initiated, even if the node has not rejoined.
</longdesc>
<shortdesc lang="en">
Do not lock resources to a cleanly shut down node longer than this
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="symmetric-cluster">
<longdesc lang="en">
Whether resources can run on any node by default
</longdesc>
<shortdesc lang="en">
Whether resources can run on any node by default
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="maintenance-mode">
<longdesc lang="en">
Whether the cluster should refrain from monitoring, starting, and stopping resources
</longdesc>
<shortdesc lang="en">
Whether the cluster should refrain from monitoring, starting, and stopping resources
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="start-failure-is-fatal">
<longdesc lang="en">
When true, the cluster will immediately ban a resource from a node if it fails to start there. When false, the cluster will instead check the resource's fail count against its migration-threshold.
</longdesc>
<shortdesc lang="en">
Whether a start failure should prevent a resource from being recovered on the same node
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="enable-startup-probes">
<longdesc lang="en">
Whether the cluster should check for active resources during start-up
</longdesc>
<shortdesc lang="en">
Whether the cluster should check for active resources during start-up
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="stonith-enabled">
<longdesc lang="en">
If false, unresponsive nodes are immediately assumed to be harmless, and resources that were active on them may be recovered elsewhere. This can result in a "split-brain" situation, potentially leading to data loss and/or service unavailability.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Whether nodes may be fenced as part of recovery
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="stonith-action">
<longdesc lang="en">
Action to send to fence device when a node needs to be fenced ("poweroff" is a deprecated alias for "off") Allowed values: reboot, off, poweroff
</longdesc>
<shortdesc lang="en">
Action to send to fence device when a node needs to be fenced ("poweroff" is a deprecated alias for "off")
</shortdesc>
<content type="select" default="">
<option value="reboot"/>
<option value="off"/>
<option value="poweroff"/>
</content>
</parameter>
<parameter name="stonith-timeout">
<longdesc lang="en">
How long to wait for on, off, and reboot fence actions to complete by default
</longdesc>
<shortdesc lang="en">
How long to wait for on, off, and reboot fence actions to complete by default
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="have-watchdog">
<longdesc lang="en">
This is set automatically by the cluster according to whether SBD is detected to be in use. User-configured values are ignored. The value `true` is meaningful if diskless SBD is used and `stonith-watchdog-timeout` is nonzero. In that case, if fencing is required, watchdog-based self-fencing will be performed via SBD without requiring a fencing resource explicitly configured.
</longdesc>
<shortdesc lang="en">
Whether watchdog integration is enabled
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="concurrent-fencing">
<longdesc lang="en">
Allow performing fencing operations in parallel
</longdesc>
<shortdesc lang="en">
Allow performing fencing operations in parallel
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="startup-fencing">
<longdesc lang="en">
Setting this to false may lead to a "split-brain" situation, potentially leading to data loss and/or service unavailability.
</longdesc>
<shortdesc lang="en">
*** Advanced Use Only *** Whether to fence unseen nodes at start-up
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="priority-fencing-delay">
<longdesc lang="en">
Apply specified delay for the fencings that are targeting the lost nodes with the highest total resource priority in case we don't have the majority of the nodes in our cluster partition, so that the more significant nodes potentially win any fencing match, which is especially meaningful under split-brain of 2-node cluster. A promoted resource instance takes the base priority + 1 on calculation if the base priority is not 0. Any static/random delays that are introduced by `pcmk_delay_base/max` configured for the corresponding fencing resources will be added to this delay. This delay should be significantly greater than, safely twice, the maximum `pcmk_delay_base/max`. By default, priority fencing delay is disabled.
</longdesc>
<shortdesc lang="en">
Apply fencing delay targeting the lost nodes with the highest total resource priority
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="node-pending-timeout">
<longdesc lang="en">
Fence nodes that do not join the controller process group within this much time after joining the cluster, to allow the cluster to continue managing resources. A value of 0 means never fence pending nodes. Setting the value to 2h means fence nodes after 2 hours.
</longdesc>
<shortdesc lang="en">
How long to wait for a node that has joined the cluster to join the controller process group
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="cluster-delay">
<longdesc lang="en">
The node elected Designated Controller (DC) will consider an action failed if it does not get a response from the node executing the action within this time (after considering the action's own timeout). The "correct" value will depend on the speed and load of your network and cluster nodes.
</longdesc>
<shortdesc lang="en">
Maximum time for node-to-node communication
</shortdesc>
<content type="time" default=""/>
</parameter>
<parameter name="batch-limit">
<longdesc lang="en">
The "correct" value will depend on the speed and load of your network and cluster nodes. If set to 0, the cluster will impose a dynamically calculated limit when any node has a high load.
</longdesc>
<shortdesc lang="en">
Maximum number of jobs that the cluster may execute in parallel across all nodes
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="migration-limit">
<longdesc lang="en">
The number of live migration actions that the cluster is allowed to execute in parallel on a node (-1 means no limit)
</longdesc>
<shortdesc lang="en">
The number of live migration actions that the cluster is allowed to execute in parallel on a node (-1 means no limit)
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="stop-all-resources">
<longdesc lang="en">
Whether the cluster should stop all active resources
</longdesc>
<shortdesc lang="en">
Whether the cluster should stop all active resources
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="stop-orphan-resources">
<longdesc lang="en">
Whether to stop resources that were removed from the configuration
</longdesc>
<shortdesc lang="en">
Whether to stop resources that were removed from the configuration
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="stop-orphan-actions">
<longdesc lang="en">
Whether to cancel recurring actions removed from the configuration
</longdesc>
<shortdesc lang="en">
Whether to cancel recurring actions removed from the configuration
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="remove-after-stop">
<longdesc lang="en">
Values other than default are poorly tested and potentially dangerous.
</longdesc>
<shortdesc lang="en">
*** Deprecated *** Whether to remove stopped resources from the executor
</shortdesc>
<content type="boolean" default=""/>
</parameter>
<parameter name="pe-error-series-max">
<longdesc lang="en">
Zero to disable, -1 to store unlimited.
</longdesc>
<shortdesc lang="en">
The number of scheduler inputs resulting in errors to save
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pe-warn-series-max">
<longdesc lang="en">
Zero to disable, -1 to store unlimited.
</longdesc>
<shortdesc lang="en">
The number of scheduler inputs resulting in warnings to save
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="pe-input-series-max">
<longdesc lang="en">
Zero to disable, -1 to store unlimited.
</longdesc>
<shortdesc lang="en">
The number of scheduler inputs without errors or warnings to save
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="node-health-strategy">
<longdesc lang="en">
Requires external entities to create node attributes (named with the prefix "#health") with values "red", "yellow", or "green". Allowed values: none, migrate-on-red, only-green, progressive, custom
</longdesc>
<shortdesc lang="en">
How cluster should react to node health attributes
</shortdesc>
<content type="select" default="">
<option value="none"/>
<option value="migrate-on-red"/>
<option value="only-green"/>
<option value="progressive"/>
<option value="custom"/>
</content>
</parameter>
<parameter name="node-health-base">
<longdesc lang="en">
Only used when "node-health-strategy" is set to "progressive".
</longdesc>
<shortdesc lang="en">
Base health score assigned to a node
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="node-health-green">
<longdesc lang="en">
Only used when "node-health-strategy" is set to "custom" or "progressive".
</longdesc>
<shortdesc lang="en">
The score to use for a node health attribute whose value is "green"
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="node-health-yellow">
<longdesc lang="en">
Only used when "node-health-strategy" is set to "custom" or "progressive".
</longdesc>
<shortdesc lang="en">
The score to use for a node health attribute whose value is "yellow"
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="node-health-red">
<longdesc lang="en">
Only used when "node-health-strategy" is set to "custom" or "progressive".
</longdesc>
<shortdesc lang="en">
The score to use for a node health attribute whose value is "red"
</shortdesc>
<content type="integer" default=""/>
</parameter>
<parameter name="placement-strategy">
<longdesc lang="en">
How the cluster should allocate resources to nodes Allowed values: default, utilization, minimal, balanced
</longdesc>
<shortdesc lang="en">
How the cluster should allocate resources to nodes
</shortdesc>
<content type="select" default="">
<option value="default"/>
<option value="utilization"/>
<option value="minimal"/>
<option value="balanced"/>
</content>
</parameter>
</parameters>
</resource-agent>
=#=#=#= End test: Get scheduler metadata - OK (0) =#=#=#=
* Passed: pacemaker-schedulerd - Get scheduler metadata
|