/*-------------------------------------------------------------------- * bgworker.c * POSTGRES pluggable background workers implementation * * Portions Copyright (c) 1996-2023, PostgreSQL Global Development Group * * IDENTIFICATION * src/backend/postmaster/bgworker.c * *------------------------------------------------------------------------- */ #include "postgres.h" #include "access/parallel.h" #include "libpq/pqsignal.h" #include "miscadmin.h" #include "pgstat.h" #include "port/atomics.h" #include "postmaster/bgworker_internals.h" #include "postmaster/interrupt.h" #include "postmaster/postmaster.h" #include "replication/logicallauncher.h" #include "replication/logicalworker.h" #include "storage/dsm.h" #include "storage/ipc.h" #include "storage/latch.h" #include "storage/lwlock.h" #include "storage/pg_shmem.h" #include "storage/pmsignal.h" #include "storage/proc.h" #include "storage/procsignal.h" #include "storage/shmem.h" #include "tcop/tcopprot.h" #include "utils/ascii.h" #include "utils/ps_status.h" #include "utils/timeout.h" /* * The postmaster's list of registered background workers, in private memory. */ slist_head BackgroundWorkerList = SLIST_STATIC_INIT(BackgroundWorkerList); /* * BackgroundWorkerSlots exist in shared memory and can be accessed (via * the BackgroundWorkerArray) by both the postmaster and by regular backends. * However, the postmaster cannot take locks, even spinlocks, because this * might allow it to crash or become wedged if shared memory gets corrupted. * Such an outcome is intolerable. Therefore, we need a lockless protocol * for coordinating access to this data. * * The 'in_use' flag is used to hand off responsibility for the slot between * the postmaster and the rest of the system. When 'in_use' is false, * the postmaster will ignore the slot entirely, except for the 'in_use' flag * itself, which it may read. In this state, regular backends may modify the * slot. Once a backend sets 'in_use' to true, the slot becomes the * responsibility of the postmaster. Regular backends may no longer modify it, * but the postmaster may examine it. Thus, a backend initializing a slot * must fully initialize the slot - and insert a write memory barrier - before * marking it as in use. * * As an exception, however, even when the slot is in use, regular backends * may set the 'terminate' flag for a slot, telling the postmaster not * to restart it. Once the background worker is no longer running, the slot * will be released for reuse. * * In addition to coordinating with the postmaster, backends modifying this * data structure must coordinate with each other. Since they can take locks, * this is straightforward: any backend wishing to manipulate a slot must * take BackgroundWorkerLock in exclusive mode. Backends wishing to read * data that might get concurrently modified by other backends should take * this lock in shared mode. No matter what, backends reading this data * structure must be able to tolerate concurrent modifications by the * postmaster. */ typedef struct BackgroundWorkerSlot { bool in_use; bool terminate; pid_t pid; /* InvalidPid = not started yet; 0 = dead */ uint64 generation; /* incremented when slot is recycled */ BackgroundWorker worker; } BackgroundWorkerSlot; /* * In order to limit the total number of parallel workers (according to * max_parallel_workers GUC), we maintain the number of active parallel * workers. Since the postmaster cannot take locks, two variables are used for * this purpose: the number of registered parallel workers (modified by the * backends, protected by BackgroundWorkerLock) and the number of terminated * parallel workers (modified only by the postmaster, lockless). The active * number of parallel workers is the number of registered workers minus the * terminated ones. These counters can of course overflow, but it's not * important here since the subtraction will still give the right number. */ typedef struct BackgroundWorkerArray { int total_slots; uint32 parallel_register_count; uint32 parallel_terminate_count; BackgroundWorkerSlot slot[FLEXIBLE_ARRAY_MEMBER]; } BackgroundWorkerArray; struct BackgroundWorkerHandle { int slot; uint64 generation; }; static BackgroundWorkerArray *BackgroundWorkerData; /* * List of internal background worker entry points. We need this for * reasons explained in LookupBackgroundWorkerFunction(), below. */ static const struct { const char *fn_name; bgworker_main_type fn_addr; } InternalBGWorkers[] = { { "ParallelWorkerMain", ParallelWorkerMain }, { "ApplyLauncherMain", ApplyLauncherMain }, { "ApplyWorkerMain", ApplyWorkerMain }, { "ParallelApplyWorkerMain", ParallelApplyWorkerMain } }; /* Private functions. */ static bgworker_main_type LookupBackgroundWorkerFunction(const char *libraryname, const char *funcname); /* * Calculate shared memory needed. */ Size BackgroundWorkerShmemSize(void) { Size size; /* Array of workers is variably sized. */ size = offsetof(BackgroundWorkerArray, slot); size = add_size(size, mul_size(max_worker_processes, sizeof(BackgroundWorkerSlot))); return size; } /* * Initialize shared memory. */ void BackgroundWorkerShmemInit(void) { bool found; BackgroundWorkerData = ShmemInitStruct("Background Worker Data", BackgroundWorkerShmemSize(), &found); if (!IsUnderPostmaster) { slist_iter siter; int slotno = 0; BackgroundWorkerData->total_slots = max_worker_processes; BackgroundWorkerData->parallel_register_count = 0; BackgroundWorkerData->parallel_terminate_count = 0; /* * Copy contents of worker list into shared memory. Record the shared * memory slot assigned to each worker. This ensures a 1-to-1 * correspondence between the postmaster's private list and the array * in shared memory. */ slist_foreach(siter, &BackgroundWorkerList) { BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno]; RegisteredBgWorker *rw; rw = slist_container(RegisteredBgWorker, rw_lnode, siter.cur); Assert(slotno < max_worker_processes); slot->in_use = true; slot->terminate = false; slot->pid = InvalidPid; slot->generation = 0; rw->rw_shmem_slot = slotno; rw->rw_worker.bgw_notify_pid = 0; /* might be reinit after crash */ memcpy(&slot->worker, &rw->rw_worker, sizeof(BackgroundWorker)); ++slotno; } /* * Mark any remaining slots as not in use. */ while (slotno < max_worker_processes) { BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno]; slot->in_use = false; ++slotno; } } else Assert(found); } /* * Search the postmaster's backend-private list of RegisteredBgWorker objects * for the one that maps to the given slot number. */ static RegisteredBgWorker * FindRegisteredWorkerBySlotNumber(int slotno) { slist_iter siter; slist_foreach(siter, &BackgroundWorkerList) { RegisteredBgWorker *rw; rw = slist_container(RegisteredBgWorker, rw_lnode, siter.cur); if (rw->rw_shmem_slot == slotno) return rw; } return NULL; } /* * Notice changes to shared memory made by other backends. * Accept new worker requests only if allow_new_workers is true. * * This code runs in the postmaster, so we must be very careful not to assume * that shared memory contents are sane. Otherwise, a rogue backend could * take out the postmaster. */ void BackgroundWorkerStateChange(bool allow_new_workers) { int slotno; /* * The total number of slots stored in shared memory should match our * notion of max_worker_processes. If it does not, something is very * wrong. Further down, we always refer to this value as * max_worker_processes, in case shared memory gets corrupted while we're * looping. */ if (max_worker_processes != BackgroundWorkerData->total_slots) { ereport(LOG, (errmsg("inconsistent background worker state (max_worker_processes=%d, total_slots=%d)", max_worker_processes, BackgroundWorkerData->total_slots))); return; } /* * Iterate through slots, looking for newly-registered workers or workers * who must die. */ for (slotno = 0; slotno < max_worker_processes; ++slotno) { BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno]; RegisteredBgWorker *rw; if (!slot->in_use) continue; /* * Make sure we don't see the in_use flag before the updated slot * contents. */ pg_read_barrier(); /* See whether we already know about this worker. */ rw = FindRegisteredWorkerBySlotNumber(slotno); if (rw != NULL) { /* * In general, the worker data can't change after it's initially * registered. However, someone can set the terminate flag. */ if (slot->terminate && !rw->rw_terminate) { rw->rw_terminate = true; if (rw->rw_pid != 0) kill(rw->rw_pid, SIGTERM); else { /* Report never-started, now-terminated worker as dead. */ ReportBackgroundWorkerPID(rw); } } continue; } /* * If we aren't allowing new workers, then immediately mark it for * termination; the next stanza will take care of cleaning it up. * Doing this ensures that any process waiting for the worker will get * awoken, even though the worker will never be allowed to run. */ if (!allow_new_workers) slot->terminate = true; /* * If the worker is marked for termination, we don't need to add it to * the registered workers list; we can just free the slot. However, if * bgw_notify_pid is set, the process that registered the worker may * need to know that we've processed the terminate request, so be sure * to signal it. */ if (slot->terminate) { int notify_pid; /* * We need a memory barrier here to make sure that the load of * bgw_notify_pid and the update of parallel_terminate_count * complete before the store to in_use. */ notify_pid = slot->worker.bgw_notify_pid; if ((slot->worker.bgw_flags & BGWORKER_CLASS_PARALLEL) != 0) BackgroundWorkerData->parallel_terminate_count++; slot->pid = 0; pg_memory_barrier(); slot->in_use = false; if (notify_pid != 0) kill(notify_pid, SIGUSR1); continue; } /* * Copy the registration data into the registered workers list. */ rw = malloc(sizeof(RegisteredBgWorker)); if (rw == NULL) { ereport(LOG, (errcode(ERRCODE_OUT_OF_MEMORY), errmsg("out of memory"))); return; } /* * Copy strings in a paranoid way. If shared memory is corrupted, the * source data might not even be NUL-terminated. */ ascii_safe_strlcpy(rw->rw_worker.bgw_name, slot->worker.bgw_name, BGW_MAXLEN); ascii_safe_strlcpy(rw->rw_worker.bgw_type, slot->worker.bgw_type, BGW_MAXLEN); ascii_safe_strlcpy(rw->rw_worker.bgw_library_name, slot->worker.bgw_library_name, BGW_MAXLEN); ascii_safe_strlcpy(rw->rw_worker.bgw_function_name, slot->worker.bgw_function_name, BGW_MAXLEN); /* * Copy various fixed-size fields. * * flags, start_time, and restart_time are examined by the postmaster, * but nothing too bad will happen if they are corrupted. The * remaining fields will only be examined by the child process. It * might crash, but we won't. */ rw->rw_worker.bgw_flags = slot->worker.bgw_flags; rw->rw_worker.bgw_start_time = slot->worker.bgw_start_time; rw->rw_worker.bgw_restart_time = slot->worker.bgw_restart_time; rw->rw_worker.bgw_main_arg = slot->worker.bgw_main_arg; memcpy(rw->rw_worker.bgw_extra, slot->worker.bgw_extra, BGW_EXTRALEN); /* * Copy the PID to be notified about state changes, but only if the * postmaster knows about a backend with that PID. It isn't an error * if the postmaster doesn't know about the PID, because the backend * that requested the worker could have died (or been killed) just * after doing so. Nonetheless, at least until we get some experience * with how this plays out in the wild, log a message at a relative * high debug level. */ rw->rw_worker.bgw_notify_pid = slot->worker.bgw_notify_pid; if (!PostmasterMarkPIDForWorkerNotify(rw->rw_worker.bgw_notify_pid)) { elog(DEBUG1, "worker notification PID %d is not valid", (int) rw->rw_worker.bgw_notify_pid); rw->rw_worker.bgw_notify_pid = 0; } /* Initialize postmaster bookkeeping. */ rw->rw_backend = NULL; rw->rw_pid = 0; rw->rw_child_slot = 0; rw->rw_crashed_at = 0; rw->rw_shmem_slot = slotno; rw->rw_terminate = false; /* Log it! */ ereport(DEBUG1, (errmsg_internal("registering background worker \"%s\"", rw->rw_worker.bgw_name))); slist_push_head(&BackgroundWorkerList, &rw->rw_lnode); } } /* * Forget about a background worker that's no longer needed. * * The worker must be identified by passing an slist_mutable_iter that * points to it. This convention allows deletion of workers during * searches of the worker list, and saves having to search the list again. * * Caller is responsible for notifying bgw_notify_pid, if appropriate. * * This function must be invoked only in the postmaster. */ void ForgetBackgroundWorker(slist_mutable_iter *cur) { RegisteredBgWorker *rw; BackgroundWorkerSlot *slot; rw = slist_container(RegisteredBgWorker, rw_lnode, cur->cur); Assert(rw->rw_shmem_slot < max_worker_processes); slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot]; Assert(slot->in_use); /* * We need a memory barrier here to make sure that the update of * parallel_terminate_count completes before the store to in_use. */ if ((rw->rw_worker.bgw_flags & BGWORKER_CLASS_PARALLEL) != 0) BackgroundWorkerData->parallel_terminate_count++; pg_memory_barrier(); slot->in_use = false; ereport(DEBUG1, (errmsg_internal("unregistering background worker \"%s\"", rw->rw_worker.bgw_name))); slist_delete_current(cur); free(rw); } /* * Report the PID of a newly-launched background worker in shared memory. * * This function should only be called from the postmaster. */ void ReportBackgroundWorkerPID(RegisteredBgWorker *rw) { BackgroundWorkerSlot *slot; Assert(rw->rw_shmem_slot < max_worker_processes); slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot]; slot->pid = rw->rw_pid; if (rw->rw_worker.bgw_notify_pid != 0) kill(rw->rw_worker.bgw_notify_pid, SIGUSR1); } /* * Report that the PID of a background worker is now zero because a * previously-running background worker has exited. * * This function should only be called from the postmaster. */ void ReportBackgroundWorkerExit(slist_mutable_iter *cur) { RegisteredBgWorker *rw; BackgroundWorkerSlot *slot; int notify_pid; rw = slist_container(RegisteredBgWorker, rw_lnode, cur->cur); Assert(rw->rw_shmem_slot < max_worker_processes); slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot]; slot->pid = rw->rw_pid; notify_pid = rw->rw_worker.bgw_notify_pid; /* * If this worker is slated for deregistration, do that before notifying * the process which started it. Otherwise, if that process tries to * reuse the slot immediately, it might not be available yet. In theory * that could happen anyway if the process checks slot->pid at just the * wrong moment, but this makes the window narrower. */ if (rw->rw_terminate || rw->rw_worker.bgw_restart_time == BGW_NEVER_RESTART) ForgetBackgroundWorker(cur); if (notify_pid != 0) kill(notify_pid, SIGUSR1); } /* * Cancel SIGUSR1 notifications for a PID belonging to an exiting backend. * * This function should only be called from the postmaster. */ void BackgroundWorkerStopNotifications(pid_t pid) { slist_iter siter; slist_foreach(siter, &BackgroundWorkerList) { RegisteredBgWorker *rw; rw = slist_container(RegisteredBgWorker, rw_lnode, siter.cur); if (rw->rw_worker.bgw_notify_pid == pid) rw->rw_worker.bgw_notify_pid = 0; } } /* * Cancel any not-yet-started worker requests that have waiting processes. * * This is called during a normal ("smart" or "fast") database shutdown. * After this point, no new background workers will be started, so anything * that might be waiting for them needs to be kicked off its wait. We do * that by canceling the bgworker registration entirely, which is perhaps * overkill, but since we're shutting down it does not matter whether the * registration record sticks around. * * This function should only be called from the postmaster. */ void ForgetUnstartedBackgroundWorkers(void) { slist_mutable_iter iter; slist_foreach_modify(iter, &BackgroundWorkerList) { RegisteredBgWorker *rw; BackgroundWorkerSlot *slot; rw = slist_container(RegisteredBgWorker, rw_lnode, iter.cur); Assert(rw->rw_shmem_slot < max_worker_processes); slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot]; /* If it's not yet started, and there's someone waiting ... */ if (slot->pid == InvalidPid && rw->rw_worker.bgw_notify_pid != 0) { /* ... then zap it, and notify the waiter */ int notify_pid = rw->rw_worker.bgw_notify_pid; ForgetBackgroundWorker(&iter); if (notify_pid != 0) kill(notify_pid, SIGUSR1); } } } /* * Reset background worker crash state. * * We assume that, after a crash-and-restart cycle, background workers without * the never-restart flag should be restarted immediately, instead of waiting * for bgw_restart_time to elapse. On the other hand, workers with that flag * should be forgotten immediately, since we won't ever restart them. * * This function should only be called from the postmaster. */ void ResetBackgroundWorkerCrashTimes(void) { slist_mutable_iter iter; slist_foreach_modify(iter, &BackgroundWorkerList) { RegisteredBgWorker *rw; rw = slist_container(RegisteredBgWorker, rw_lnode, iter.cur); if (rw->rw_worker.bgw_restart_time == BGW_NEVER_RESTART) { /* * Workers marked BGW_NEVER_RESTART shouldn't get relaunched after * the crash, so forget about them. (If we wait until after the * crash to forget about them, and they are parallel workers, * parallel_terminate_count will get incremented after we've * already zeroed parallel_register_count, which would be bad.) */ ForgetBackgroundWorker(&iter); } else { /* * The accounting which we do via parallel_register_count and * parallel_terminate_count would get messed up if a worker marked * parallel could survive a crash and restart cycle. All such * workers should be marked BGW_NEVER_RESTART, and thus control * should never reach this branch. */ Assert((rw->rw_worker.bgw_flags & BGWORKER_CLASS_PARALLEL) == 0); /* * Allow this worker to be restarted immediately after we finish * resetting. */ rw->rw_crashed_at = 0; /* * If there was anyone waiting for it, they're history. */ rw->rw_worker.bgw_notify_pid = 0; } } } #ifdef EXEC_BACKEND /* * In EXEC_BACKEND mode, workers use this to retrieve their details from * shared memory. */ BackgroundWorker * BackgroundWorkerEntry(int slotno) { static BackgroundWorker myEntry; BackgroundWorkerSlot *slot; Assert(slotno < BackgroundWorkerData->total_slots); slot = &BackgroundWorkerData->slot[slotno]; Assert(slot->in_use); /* must copy this in case we don't intend to retain shmem access */ memcpy(&myEntry, &slot->worker, sizeof myEntry); return &myEntry; } #endif /* * Complain about the BackgroundWorker definition using error level elevel. * Return true if it looks ok, false if not (unless elevel >= ERROR, in * which case we won't return at all in the not-OK case). */ static bool SanityCheckBackgroundWorker(BackgroundWorker *worker, int elevel) { /* sanity check for flags */ /* * We used to support workers not connected to shared memory, but don't * anymore. Thus this is a required flag now. We're not removing the flag * for compatibility reasons and because the flag still provides some * signal when reading code. */ if (!(worker->bgw_flags & BGWORKER_SHMEM_ACCESS)) { ereport(elevel, (errcode(ERRCODE_INVALID_PARAMETER_VALUE), errmsg("background worker \"%s\": background workers without shared memory access are not supported", worker->bgw_name))); return false; } if (worker->bgw_flags & BGWORKER_BACKEND_DATABASE_CONNECTION) { if (worker->bgw_start_time == BgWorkerStart_PostmasterStart) { ereport(elevel, (errcode(ERRCODE_INVALID_PARAMETER_VALUE), errmsg("background worker \"%s\": cannot request database access if starting at postmaster start", worker->bgw_name))); return false; } /* XXX other checks? */ } if ((worker->bgw_restart_time < 0 && worker->bgw_restart_time != BGW_NEVER_RESTART) || (worker->bgw_restart_time > USECS_PER_DAY / 1000)) { ereport(elevel, (errcode(ERRCODE_INVALID_PARAMETER_VALUE), errmsg("background worker \"%s\": invalid restart interval", worker->bgw_name))); return false; } /* * Parallel workers may not be configured for restart, because the * parallel_register_count/parallel_terminate_count accounting can't * handle parallel workers lasting through a crash-and-restart cycle. */ if (worker->bgw_restart_time != BGW_NEVER_RESTART && (worker->bgw_flags & BGWORKER_CLASS_PARALLEL) != 0) { ereport(elevel, (errcode(ERRCODE_INVALID_PARAMETER_VALUE), errmsg("background worker \"%s\": parallel workers may not be configured for restart", worker->bgw_name))); return false; } /* * If bgw_type is not filled in, use bgw_name. */ if (strcmp(worker->bgw_type, "") == 0) strcpy(worker->bgw_type, worker->bgw_name); return true; } /* * Standard SIGTERM handler for background workers */ static void bgworker_die(SIGNAL_ARGS) { sigprocmask(SIG_SETMASK, &BlockSig, NULL); ereport(FATAL, (errcode(ERRCODE_ADMIN_SHUTDOWN), errmsg("terminating background worker \"%s\" due to administrator command", MyBgworkerEntry->bgw_type))); } /* * Start a new background worker * * This is the main entry point for background worker, to be called from * postmaster. */ void StartBackgroundWorker(void) { sigjmp_buf local_sigjmp_buf; BackgroundWorker *worker = MyBgworkerEntry; bgworker_main_type entrypt; if (worker == NULL) elog(FATAL, "unable to find bgworker entry"); IsBackgroundWorker = true; MyBackendType = B_BG_WORKER; init_ps_display(worker->bgw_name); SetProcessingMode(InitProcessing); /* Apply PostAuthDelay */ if (PostAuthDelay > 0) pg_usleep(PostAuthDelay * 1000000L); /* * Set up signal handlers. */ if (worker->bgw_flags & BGWORKER_BACKEND_DATABASE_CONNECTION) { /* * SIGINT is used to signal canceling the current action */ pqsignal(SIGINT, StatementCancelHandler); pqsignal(SIGUSR1, procsignal_sigusr1_handler); pqsignal(SIGFPE, FloatExceptionHandler); /* XXX Any other handlers needed here? */ } else { pqsignal(SIGINT, SIG_IGN); pqsignal(SIGUSR1, SIG_IGN); pqsignal(SIGFPE, SIG_IGN); } pqsignal(SIGTERM, bgworker_die); /* SIGQUIT handler was already set up by InitPostmasterChild */ pqsignal(SIGHUP, SIG_IGN); InitializeTimeouts(); /* establishes SIGALRM handler */ pqsignal(SIGPIPE, SIG_IGN); pqsignal(SIGUSR2, SIG_IGN); pqsignal(SIGCHLD, SIG_DFL); /* * If an exception is encountered, processing resumes here. * * We just need to clean up, report the error, and go away. */ if (sigsetjmp(local_sigjmp_buf, 1) != 0) { /* Since not using PG_TRY, must reset error stack by hand */ error_context_stack = NULL; /* Prevent interrupts while cleaning up */ HOLD_INTERRUPTS(); /* * sigsetjmp will have blocked all signals, but we may need to accept * signals while communicating with our parallel leader. Once we've * done HOLD_INTERRUPTS() it should be safe to unblock signals. */ BackgroundWorkerUnblockSignals(); /* Report the error to the parallel leader and the server log */ EmitErrorReport(); /* * Do we need more cleanup here? For shmem-connected bgworkers, we * will call InitProcess below, which will install ProcKill as exit * callback. That will take care of releasing locks, etc. */ /* and go away */ proc_exit(1); } /* We can now handle ereport(ERROR) */ PG_exception_stack = &local_sigjmp_buf; /* * Create a per-backend PGPROC struct in shared memory, except in the * EXEC_BACKEND case where this was done in SubPostmasterMain. We must do * this before we can use LWLocks (and in the EXEC_BACKEND case we already * had to do some stuff with LWLocks). */ #ifndef EXEC_BACKEND InitProcess(); #endif /* * Early initialization. */ BaseInit(); /* * Look up the entry point function, loading its library if necessary. */ entrypt = LookupBackgroundWorkerFunction(worker->bgw_library_name, worker->bgw_function_name); /* * Note that in normal processes, we would call InitPostgres here. For a * worker, however, we don't know what database to connect to, yet; so we * need to wait until the user code does it via * BackgroundWorkerInitializeConnection(). */ /* * Now invoke the user-defined worker code */ entrypt(worker->bgw_main_arg); /* ... and if it returns, we're done */ proc_exit(0); } /* * Register a new static background worker. * * This can only be called directly from postmaster or in the _PG_init * function of a module library that's loaded by shared_preload_libraries; * otherwise it will have no effect. */ void RegisterBackgroundWorker(BackgroundWorker *worker) { RegisteredBgWorker *rw; static int numworkers = 0; if (!IsUnderPostmaster) ereport(DEBUG1, (errmsg_internal("registering background worker \"%s\"", worker->bgw_name))); if (!process_shared_preload_libraries_in_progress && strcmp(worker->bgw_library_name, "postgres") != 0) { if (!IsUnderPostmaster) ereport(LOG, (errcode(ERRCODE_FEATURE_NOT_SUPPORTED), errmsg("background worker \"%s\": must be registered in shared_preload_libraries", worker->bgw_name))); return; } if (!SanityCheckBackgroundWorker(worker, LOG)) return; if (worker->bgw_notify_pid != 0) { ereport(LOG, (errcode(ERRCODE_FEATURE_NOT_SUPPORTED), errmsg("background worker \"%s\": only dynamic background workers can request notification", worker->bgw_name))); return; } /* * Enforce maximum number of workers. Note this is overly restrictive: we * could allow more non-shmem-connected workers, because these don't count * towards the MAX_BACKENDS limit elsewhere. For now, it doesn't seem * important to relax this restriction. */ if (++numworkers > max_worker_processes) { ereport(LOG, (errcode(ERRCODE_CONFIGURATION_LIMIT_EXCEEDED), errmsg("too many background workers"), errdetail_plural("Up to %d background worker can be registered with the current settings.", "Up to %d background workers can be registered with the current settings.", max_worker_processes, max_worker_processes), errhint("Consider increasing the configuration parameter \"max_worker_processes\"."))); return; } /* * Copy the registration data into the registered workers list. */ rw = malloc(sizeof(RegisteredBgWorker)); if (rw == NULL) { ereport(LOG, (errcode(ERRCODE_OUT_OF_MEMORY), errmsg("out of memory"))); return; } rw->rw_worker = *worker; rw->rw_backend = NULL; rw->rw_pid = 0; rw->rw_child_slot = 0; rw->rw_crashed_at = 0; rw->rw_terminate = false; slist_push_head(&BackgroundWorkerList, &rw->rw_lnode); } /* * Register a new background worker from a regular backend. * * Returns true on success and false on failure. Failure typically indicates * that no background worker slots are currently available. * * If handle != NULL, we'll set *handle to a pointer that can subsequently * be used as an argument to GetBackgroundWorkerPid(). The caller can * free this pointer using pfree(), if desired. */ bool RegisterDynamicBackgroundWorker(BackgroundWorker *worker, BackgroundWorkerHandle **handle) { int slotno; bool success = false; bool parallel; uint64 generation = 0; /* * We can't register dynamic background workers from the postmaster. If * this is a standalone backend, we're the only process and can't start * any more. In a multi-process environment, it might be theoretically * possible, but we don't currently support it due to locking * considerations; see comments on the BackgroundWorkerSlot data * structure. */ if (!IsUnderPostmaster) return false; if (!SanityCheckBackgroundWorker(worker, ERROR)) return false; parallel = (worker->bgw_flags & BGWORKER_CLASS_PARALLEL) != 0; LWLockAcquire(BackgroundWorkerLock, LW_EXCLUSIVE); /* * If this is a parallel worker, check whether there are already too many * parallel workers; if so, don't register another one. Our view of * parallel_terminate_count may be slightly stale, but that doesn't really * matter: we would have gotten the same result if we'd arrived here * slightly earlier anyway. There's no help for it, either, since the * postmaster must not take locks; a memory barrier wouldn't guarantee * anything useful. */ if (parallel && (BackgroundWorkerData->parallel_register_count - BackgroundWorkerData->parallel_terminate_count) >= max_parallel_workers) { Assert(BackgroundWorkerData->parallel_register_count - BackgroundWorkerData->parallel_terminate_count <= MAX_PARALLEL_WORKER_LIMIT); LWLockRelease(BackgroundWorkerLock); return false; } /* * Look for an unused slot. If we find one, grab it. */ for (slotno = 0; slotno < BackgroundWorkerData->total_slots; ++slotno) { BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno]; if (!slot->in_use) { memcpy(&slot->worker, worker, sizeof(BackgroundWorker)); slot->pid = InvalidPid; /* indicates not started yet */ slot->generation++; slot->terminate = false; generation = slot->generation; if (parallel) BackgroundWorkerData->parallel_register_count++; /* * Make sure postmaster doesn't see the slot as in use before it * sees the new contents. */ pg_write_barrier(); slot->in_use = true; success = true; break; } } LWLockRelease(BackgroundWorkerLock); /* If we found a slot, tell the postmaster to notice the change. */ if (success) SendPostmasterSignal(PMSIGNAL_BACKGROUND_WORKER_CHANGE); /* * If we found a slot and the user has provided a handle, initialize it. */ if (success && handle) { *handle = palloc(sizeof(BackgroundWorkerHandle)); (*handle)->slot = slotno; (*handle)->generation = generation; } return success; } /* * Get the PID of a dynamically-registered background worker. * * If the worker is determined to be running, the return value will be * BGWH_STARTED and *pidp will get the PID of the worker process. If the * postmaster has not yet attempted to start the worker, the return value will * be BGWH_NOT_YET_STARTED. Otherwise, the return value is BGWH_STOPPED. * * BGWH_STOPPED can indicate either that the worker is temporarily stopped * (because it is configured for automatic restart and exited non-zero), * or that the worker is permanently stopped (because it exited with exit * code 0, or was not configured for automatic restart), or even that the * worker was unregistered without ever starting (either because startup * failed and the worker is not configured for automatic restart, or because * TerminateBackgroundWorker was used before the worker was successfully * started). */ BgwHandleStatus GetBackgroundWorkerPid(BackgroundWorkerHandle *handle, pid_t *pidp) { BackgroundWorkerSlot *slot; pid_t pid; Assert(handle->slot < max_worker_processes); slot = &BackgroundWorkerData->slot[handle->slot]; /* * We could probably arrange to synchronize access to data using memory * barriers only, but for now, let's just keep it simple and grab the * lock. It seems unlikely that there will be enough traffic here to * result in meaningful contention. */ LWLockAcquire(BackgroundWorkerLock, LW_SHARED); /* * The generation number can't be concurrently changed while we hold the * lock. The pid, which is updated by the postmaster, can change at any * time, but we assume such changes are atomic. So the value we read * won't be garbage, but it might be out of date by the time the caller * examines it (but that's unavoidable anyway). * * The in_use flag could be in the process of changing from true to false, * but if it is already false then it can't change further. */ if (handle->generation != slot->generation || !slot->in_use) pid = 0; else pid = slot->pid; /* All done. */ LWLockRelease(BackgroundWorkerLock); if (pid == 0) return BGWH_STOPPED; else if (pid == InvalidPid) return BGWH_NOT_YET_STARTED; *pidp = pid; return BGWH_STARTED; } /* * Wait for a background worker to start up. * * This is like GetBackgroundWorkerPid(), except that if the worker has not * yet started, we wait for it to do so; thus, BGWH_NOT_YET_STARTED is never * returned. However, if the postmaster has died, we give up and return * BGWH_POSTMASTER_DIED, since it that case we know that startup will not * take place. * * The caller *must* have set our PID as the worker's bgw_notify_pid, * else we will not be awoken promptly when the worker's state changes. */ BgwHandleStatus WaitForBackgroundWorkerStartup(BackgroundWorkerHandle *handle, pid_t *pidp) { BgwHandleStatus status; int rc; for (;;) { pid_t pid; CHECK_FOR_INTERRUPTS(); status = GetBackgroundWorkerPid(handle, &pid); if (status == BGWH_STARTED) *pidp = pid; if (status != BGWH_NOT_YET_STARTED) break; rc = WaitLatch(MyLatch, WL_LATCH_SET | WL_POSTMASTER_DEATH, 0, WAIT_EVENT_BGWORKER_STARTUP); if (rc & WL_POSTMASTER_DEATH) { status = BGWH_POSTMASTER_DIED; break; } ResetLatch(MyLatch); } return status; } /* * Wait for a background worker to stop. * * If the worker hasn't yet started, or is running, we wait for it to stop * and then return BGWH_STOPPED. However, if the postmaster has died, we give * up and return BGWH_POSTMASTER_DIED, because it's the postmaster that * notifies us when a worker's state changes. * * The caller *must* have set our PID as the worker's bgw_notify_pid, * else we will not be awoken promptly when the worker's state changes. */ BgwHandleStatus WaitForBackgroundWorkerShutdown(BackgroundWorkerHandle *handle) { BgwHandleStatus status; int rc; for (;;) { pid_t pid; CHECK_FOR_INTERRUPTS(); status = GetBackgroundWorkerPid(handle, &pid); if (status == BGWH_STOPPED) break; rc = WaitLatch(MyLatch, WL_LATCH_SET | WL_POSTMASTER_DEATH, 0, WAIT_EVENT_BGWORKER_SHUTDOWN); if (rc & WL_POSTMASTER_DEATH) { status = BGWH_POSTMASTER_DIED; break; } ResetLatch(MyLatch); } return status; } /* * Instruct the postmaster to terminate a background worker. * * Note that it's safe to do this without regard to whether the worker is * still running, or even if the worker may already have exited and been * unregistered. */ void TerminateBackgroundWorker(BackgroundWorkerHandle *handle) { BackgroundWorkerSlot *slot; bool signal_postmaster = false; Assert(handle->slot < max_worker_processes); slot = &BackgroundWorkerData->slot[handle->slot]; /* Set terminate flag in shared memory, unless slot has been reused. */ LWLockAcquire(BackgroundWorkerLock, LW_EXCLUSIVE); if (handle->generation == slot->generation) { slot->terminate = true; signal_postmaster = true; } LWLockRelease(BackgroundWorkerLock); /* Make sure the postmaster notices the change to shared memory. */ if (signal_postmaster) SendPostmasterSignal(PMSIGNAL_BACKGROUND_WORKER_CHANGE); } /* * Look up (and possibly load) a bgworker entry point function. * * For functions contained in the core code, we use library name "postgres" * and consult the InternalBGWorkers array. External functions are * looked up, and loaded if necessary, using load_external_function(). * * The point of this is to pass function names as strings across process * boundaries. We can't pass actual function addresses because of the * possibility that the function has been loaded at a different address * in a different process. This is obviously a hazard for functions in * loadable libraries, but it can happen even for functions in the core code * on platforms using EXEC_BACKEND (e.g., Windows). * * At some point it might be worthwhile to get rid of InternalBGWorkers[] * in favor of applying load_external_function() for core functions too; * but that raises portability issues that are not worth addressing now. */ static bgworker_main_type LookupBackgroundWorkerFunction(const char *libraryname, const char *funcname) { /* * If the function is to be loaded from postgres itself, search the * InternalBGWorkers array. */ if (strcmp(libraryname, "postgres") == 0) { int i; for (i = 0; i < lengthof(InternalBGWorkers); i++) { if (strcmp(InternalBGWorkers[i].fn_name, funcname) == 0) return InternalBGWorkers[i].fn_addr; } /* We can only reach this by programming error. */ elog(ERROR, "internal function \"%s\" not found", funcname); } /* Otherwise load from external library. */ return (bgworker_main_type) load_external_function(libraryname, funcname, true, NULL); } /* * Given a PID, get the bgw_type of the background worker. Returns NULL if * not a valid background worker. * * The return value is in static memory belonging to this function, so it has * to be used before calling this function again. This is so that the caller * doesn't have to worry about the background worker locking protocol. */ const char * GetBackgroundWorkerTypeByPid(pid_t pid) { int slotno; bool found = false; static char result[BGW_MAXLEN]; LWLockAcquire(BackgroundWorkerLock, LW_SHARED); for (slotno = 0; slotno < BackgroundWorkerData->total_slots; slotno++) { BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno]; if (slot->pid > 0 && slot->pid == pid) { strcpy(result, slot->worker.bgw_type); found = true; break; } } LWLockRelease(BackgroundWorkerLock); if (!found) return NULL; return result; }