1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
|
/*--------------------------------------------------------------------
* bgworker.c
* POSTGRES pluggable background workers implementation
*
* Portions Copyright (c) 1996-2023, PostgreSQL Global Development Group
*
* IDENTIFICATION
* src/backend/postmaster/bgworker.c
*
*-------------------------------------------------------------------------
*/
#include "postgres.h"
#include "access/parallel.h"
#include "libpq/pqsignal.h"
#include "miscadmin.h"
#include "pgstat.h"
#include "port/atomics.h"
#include "postmaster/bgworker_internals.h"
#include "postmaster/interrupt.h"
#include "postmaster/postmaster.h"
#include "replication/logicallauncher.h"
#include "replication/logicalworker.h"
#include "storage/dsm.h"
#include "storage/ipc.h"
#include "storage/latch.h"
#include "storage/lwlock.h"
#include "storage/pg_shmem.h"
#include "storage/pmsignal.h"
#include "storage/proc.h"
#include "storage/procsignal.h"
#include "storage/shmem.h"
#include "tcop/tcopprot.h"
#include "utils/ascii.h"
#include "utils/ps_status.h"
#include "utils/timeout.h"
/*
* The postmaster's list of registered background workers, in private memory.
*/
slist_head BackgroundWorkerList = SLIST_STATIC_INIT(BackgroundWorkerList);
/*
* BackgroundWorkerSlots exist in shared memory and can be accessed (via
* the BackgroundWorkerArray) by both the postmaster and by regular backends.
* However, the postmaster cannot take locks, even spinlocks, because this
* might allow it to crash or become wedged if shared memory gets corrupted.
* Such an outcome is intolerable. Therefore, we need a lockless protocol
* for coordinating access to this data.
*
* The 'in_use' flag is used to hand off responsibility for the slot between
* the postmaster and the rest of the system. When 'in_use' is false,
* the postmaster will ignore the slot entirely, except for the 'in_use' flag
* itself, which it may read. In this state, regular backends may modify the
* slot. Once a backend sets 'in_use' to true, the slot becomes the
* responsibility of the postmaster. Regular backends may no longer modify it,
* but the postmaster may examine it. Thus, a backend initializing a slot
* must fully initialize the slot - and insert a write memory barrier - before
* marking it as in use.
*
* As an exception, however, even when the slot is in use, regular backends
* may set the 'terminate' flag for a slot, telling the postmaster not
* to restart it. Once the background worker is no longer running, the slot
* will be released for reuse.
*
* In addition to coordinating with the postmaster, backends modifying this
* data structure must coordinate with each other. Since they can take locks,
* this is straightforward: any backend wishing to manipulate a slot must
* take BackgroundWorkerLock in exclusive mode. Backends wishing to read
* data that might get concurrently modified by other backends should take
* this lock in shared mode. No matter what, backends reading this data
* structure must be able to tolerate concurrent modifications by the
* postmaster.
*/
typedef struct BackgroundWorkerSlot
{
bool in_use;
bool terminate;
pid_t pid; /* InvalidPid = not started yet; 0 = dead */
uint64 generation; /* incremented when slot is recycled */
BackgroundWorker worker;
} BackgroundWorkerSlot;
/*
* In order to limit the total number of parallel workers (according to
* max_parallel_workers GUC), we maintain the number of active parallel
* workers. Since the postmaster cannot take locks, two variables are used for
* this purpose: the number of registered parallel workers (modified by the
* backends, protected by BackgroundWorkerLock) and the number of terminated
* parallel workers (modified only by the postmaster, lockless). The active
* number of parallel workers is the number of registered workers minus the
* terminated ones. These counters can of course overflow, but it's not
* important here since the subtraction will still give the right number.
*/
typedef struct BackgroundWorkerArray
{
int total_slots;
uint32 parallel_register_count;
uint32 parallel_terminate_count;
BackgroundWorkerSlot slot[FLEXIBLE_ARRAY_MEMBER];
} BackgroundWorkerArray;
struct BackgroundWorkerHandle
{
int slot;
uint64 generation;
};
static BackgroundWorkerArray *BackgroundWorkerData;
/*
* List of internal background worker entry points. We need this for
* reasons explained in LookupBackgroundWorkerFunction(), below.
*/
static const struct
{
const char *fn_name;
bgworker_main_type fn_addr;
} InternalBGWorkers[] =
{
{
"ParallelWorkerMain", ParallelWorkerMain
},
{
"ApplyLauncherMain", ApplyLauncherMain
},
{
"ApplyWorkerMain", ApplyWorkerMain
},
{
"ParallelApplyWorkerMain", ParallelApplyWorkerMain
}
};
/* Private functions. */
static bgworker_main_type LookupBackgroundWorkerFunction(const char *libraryname, const char *funcname);
/*
* Calculate shared memory needed.
*/
Size
BackgroundWorkerShmemSize(void)
{
Size size;
/* Array of workers is variably sized. */
size = offsetof(BackgroundWorkerArray, slot);
size = add_size(size, mul_size(max_worker_processes,
sizeof(BackgroundWorkerSlot)));
return size;
}
/*
* Initialize shared memory.
*/
void
BackgroundWorkerShmemInit(void)
{
bool found;
BackgroundWorkerData = ShmemInitStruct("Background Worker Data",
BackgroundWorkerShmemSize(),
&found);
if (!IsUnderPostmaster)
{
slist_iter siter;
int slotno = 0;
BackgroundWorkerData->total_slots = max_worker_processes;
BackgroundWorkerData->parallel_register_count = 0;
BackgroundWorkerData->parallel_terminate_count = 0;
/*
* Copy contents of worker list into shared memory. Record the shared
* memory slot assigned to each worker. This ensures a 1-to-1
* correspondence between the postmaster's private list and the array
* in shared memory.
*/
slist_foreach(siter, &BackgroundWorkerList)
{
BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno];
RegisteredBgWorker *rw;
rw = slist_container(RegisteredBgWorker, rw_lnode, siter.cur);
Assert(slotno < max_worker_processes);
slot->in_use = true;
slot->terminate = false;
slot->pid = InvalidPid;
slot->generation = 0;
rw->rw_shmem_slot = slotno;
rw->rw_worker.bgw_notify_pid = 0; /* might be reinit after crash */
memcpy(&slot->worker, &rw->rw_worker, sizeof(BackgroundWorker));
++slotno;
}
/*
* Mark any remaining slots as not in use.
*/
while (slotno < max_worker_processes)
{
BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno];
slot->in_use = false;
++slotno;
}
}
else
Assert(found);
}
/*
* Search the postmaster's backend-private list of RegisteredBgWorker objects
* for the one that maps to the given slot number.
*/
static RegisteredBgWorker *
FindRegisteredWorkerBySlotNumber(int slotno)
{
slist_iter siter;
slist_foreach(siter, &BackgroundWorkerList)
{
RegisteredBgWorker *rw;
rw = slist_container(RegisteredBgWorker, rw_lnode, siter.cur);
if (rw->rw_shmem_slot == slotno)
return rw;
}
return NULL;
}
/*
* Notice changes to shared memory made by other backends.
* Accept new worker requests only if allow_new_workers is true.
*
* This code runs in the postmaster, so we must be very careful not to assume
* that shared memory contents are sane. Otherwise, a rogue backend could
* take out the postmaster.
*/
void
BackgroundWorkerStateChange(bool allow_new_workers)
{
int slotno;
/*
* The total number of slots stored in shared memory should match our
* notion of max_worker_processes. If it does not, something is very
* wrong. Further down, we always refer to this value as
* max_worker_processes, in case shared memory gets corrupted while we're
* looping.
*/
if (max_worker_processes != BackgroundWorkerData->total_slots)
{
ereport(LOG,
(errmsg("inconsistent background worker state (max_worker_processes=%d, total_slots=%d)",
max_worker_processes,
BackgroundWorkerData->total_slots)));
return;
}
/*
* Iterate through slots, looking for newly-registered workers or workers
* who must die.
*/
for (slotno = 0; slotno < max_worker_processes; ++slotno)
{
BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno];
RegisteredBgWorker *rw;
if (!slot->in_use)
continue;
/*
* Make sure we don't see the in_use flag before the updated slot
* contents.
*/
pg_read_barrier();
/* See whether we already know about this worker. */
rw = FindRegisteredWorkerBySlotNumber(slotno);
if (rw != NULL)
{
/*
* In general, the worker data can't change after it's initially
* registered. However, someone can set the terminate flag.
*/
if (slot->terminate && !rw->rw_terminate)
{
rw->rw_terminate = true;
if (rw->rw_pid != 0)
kill(rw->rw_pid, SIGTERM);
else
{
/* Report never-started, now-terminated worker as dead. */
ReportBackgroundWorkerPID(rw);
}
}
continue;
}
/*
* If we aren't allowing new workers, then immediately mark it for
* termination; the next stanza will take care of cleaning it up.
* Doing this ensures that any process waiting for the worker will get
* awoken, even though the worker will never be allowed to run.
*/
if (!allow_new_workers)
slot->terminate = true;
/*
* If the worker is marked for termination, we don't need to add it to
* the registered workers list; we can just free the slot. However, if
* bgw_notify_pid is set, the process that registered the worker may
* need to know that we've processed the terminate request, so be sure
* to signal it.
*/
if (slot->terminate)
{
int notify_pid;
/*
* We need a memory barrier here to make sure that the load of
* bgw_notify_pid and the update of parallel_terminate_count
* complete before the store to in_use.
*/
notify_pid = slot->worker.bgw_notify_pid;
if ((slot->worker.bgw_flags & BGWORKER_CLASS_PARALLEL) != 0)
BackgroundWorkerData->parallel_terminate_count++;
slot->pid = 0;
pg_memory_barrier();
slot->in_use = false;
if (notify_pid != 0)
kill(notify_pid, SIGUSR1);
continue;
}
/*
* Copy the registration data into the registered workers list.
*/
rw = malloc(sizeof(RegisteredBgWorker));
if (rw == NULL)
{
ereport(LOG,
(errcode(ERRCODE_OUT_OF_MEMORY),
errmsg("out of memory")));
return;
}
/*
* Copy strings in a paranoid way. If shared memory is corrupted, the
* source data might not even be NUL-terminated.
*/
ascii_safe_strlcpy(rw->rw_worker.bgw_name,
slot->worker.bgw_name, BGW_MAXLEN);
ascii_safe_strlcpy(rw->rw_worker.bgw_type,
slot->worker.bgw_type, BGW_MAXLEN);
ascii_safe_strlcpy(rw->rw_worker.bgw_library_name,
slot->worker.bgw_library_name, BGW_MAXLEN);
ascii_safe_strlcpy(rw->rw_worker.bgw_function_name,
slot->worker.bgw_function_name, BGW_MAXLEN);
/*
* Copy various fixed-size fields.
*
* flags, start_time, and restart_time are examined by the postmaster,
* but nothing too bad will happen if they are corrupted. The
* remaining fields will only be examined by the child process. It
* might crash, but we won't.
*/
rw->rw_worker.bgw_flags = slot->worker.bgw_flags;
rw->rw_worker.bgw_start_time = slot->worker.bgw_start_time;
rw->rw_worker.bgw_restart_time = slot->worker.bgw_restart_time;
rw->rw_worker.bgw_main_arg = slot->worker.bgw_main_arg;
memcpy(rw->rw_worker.bgw_extra, slot->worker.bgw_extra, BGW_EXTRALEN);
/*
* Copy the PID to be notified about state changes, but only if the
* postmaster knows about a backend with that PID. It isn't an error
* if the postmaster doesn't know about the PID, because the backend
* that requested the worker could have died (or been killed) just
* after doing so. Nonetheless, at least until we get some experience
* with how this plays out in the wild, log a message at a relative
* high debug level.
*/
rw->rw_worker.bgw_notify_pid = slot->worker.bgw_notify_pid;
if (!PostmasterMarkPIDForWorkerNotify(rw->rw_worker.bgw_notify_pid))
{
elog(DEBUG1, "worker notification PID %d is not valid",
(int) rw->rw_worker.bgw_notify_pid);
rw->rw_worker.bgw_notify_pid = 0;
}
/* Initialize postmaster bookkeeping. */
rw->rw_backend = NULL;
rw->rw_pid = 0;
rw->rw_child_slot = 0;
rw->rw_crashed_at = 0;
rw->rw_shmem_slot = slotno;
rw->rw_terminate = false;
/* Log it! */
ereport(DEBUG1,
(errmsg_internal("registering background worker \"%s\"",
rw->rw_worker.bgw_name)));
slist_push_head(&BackgroundWorkerList, &rw->rw_lnode);
}
}
/*
* Forget about a background worker that's no longer needed.
*
* The worker must be identified by passing an slist_mutable_iter that
* points to it. This convention allows deletion of workers during
* searches of the worker list, and saves having to search the list again.
*
* Caller is responsible for notifying bgw_notify_pid, if appropriate.
*
* This function must be invoked only in the postmaster.
*/
void
ForgetBackgroundWorker(slist_mutable_iter *cur)
{
RegisteredBgWorker *rw;
BackgroundWorkerSlot *slot;
rw = slist_container(RegisteredBgWorker, rw_lnode, cur->cur);
Assert(rw->rw_shmem_slot < max_worker_processes);
slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot];
Assert(slot->in_use);
/*
* We need a memory barrier here to make sure that the update of
* parallel_terminate_count completes before the store to in_use.
*/
if ((rw->rw_worker.bgw_flags & BGWORKER_CLASS_PARALLEL) != 0)
BackgroundWorkerData->parallel_terminate_count++;
pg_memory_barrier();
slot->in_use = false;
ereport(DEBUG1,
(errmsg_internal("unregistering background worker \"%s\"",
rw->rw_worker.bgw_name)));
slist_delete_current(cur);
free(rw);
}
/*
* Report the PID of a newly-launched background worker in shared memory.
*
* This function should only be called from the postmaster.
*/
void
ReportBackgroundWorkerPID(RegisteredBgWorker *rw)
{
BackgroundWorkerSlot *slot;
Assert(rw->rw_shmem_slot < max_worker_processes);
slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot];
slot->pid = rw->rw_pid;
if (rw->rw_worker.bgw_notify_pid != 0)
kill(rw->rw_worker.bgw_notify_pid, SIGUSR1);
}
/*
* Report that the PID of a background worker is now zero because a
* previously-running background worker has exited.
*
* This function should only be called from the postmaster.
*/
void
ReportBackgroundWorkerExit(slist_mutable_iter *cur)
{
RegisteredBgWorker *rw;
BackgroundWorkerSlot *slot;
int notify_pid;
rw = slist_container(RegisteredBgWorker, rw_lnode, cur->cur);
Assert(rw->rw_shmem_slot < max_worker_processes);
slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot];
slot->pid = rw->rw_pid;
notify_pid = rw->rw_worker.bgw_notify_pid;
/*
* If this worker is slated for deregistration, do that before notifying
* the process which started it. Otherwise, if that process tries to
* reuse the slot immediately, it might not be available yet. In theory
* that could happen anyway if the process checks slot->pid at just the
* wrong moment, but this makes the window narrower.
*/
if (rw->rw_terminate ||
rw->rw_worker.bgw_restart_time == BGW_NEVER_RESTART)
ForgetBackgroundWorker(cur);
if (notify_pid != 0)
kill(notify_pid, SIGUSR1);
}
/*
* Cancel SIGUSR1 notifications for a PID belonging to an exiting backend.
*
* This function should only be called from the postmaster.
*/
void
BackgroundWorkerStopNotifications(pid_t pid)
{
slist_iter siter;
slist_foreach(siter, &BackgroundWorkerList)
{
RegisteredBgWorker *rw;
rw = slist_container(RegisteredBgWorker, rw_lnode, siter.cur);
if (rw->rw_worker.bgw_notify_pid == pid)
rw->rw_worker.bgw_notify_pid = 0;
}
}
/*
* Cancel any not-yet-started worker requests that have waiting processes.
*
* This is called during a normal ("smart" or "fast") database shutdown.
* After this point, no new background workers will be started, so anything
* that might be waiting for them needs to be kicked off its wait. We do
* that by canceling the bgworker registration entirely, which is perhaps
* overkill, but since we're shutting down it does not matter whether the
* registration record sticks around.
*
* This function should only be called from the postmaster.
*/
void
ForgetUnstartedBackgroundWorkers(void)
{
slist_mutable_iter iter;
slist_foreach_modify(iter, &BackgroundWorkerList)
{
RegisteredBgWorker *rw;
BackgroundWorkerSlot *slot;
rw = slist_container(RegisteredBgWorker, rw_lnode, iter.cur);
Assert(rw->rw_shmem_slot < max_worker_processes);
slot = &BackgroundWorkerData->slot[rw->rw_shmem_slot];
/* If it's not yet started, and there's someone waiting ... */
if (slot->pid == InvalidPid &&
rw->rw_worker.bgw_notify_pid != 0)
{
/* ... then zap it, and notify the waiter */
int notify_pid = rw->rw_worker.bgw_notify_pid;
ForgetBackgroundWorker(&iter);
if (notify_pid != 0)
kill(notify_pid, SIGUSR1);
}
}
}
/*
* Reset background worker crash state.
*
* We assume that, after a crash-and-restart cycle, background workers without
* the never-restart flag should be restarted immediately, instead of waiting
* for bgw_restart_time to elapse. On the other hand, workers with that flag
* should be forgotten immediately, since we won't ever restart them.
*
* This function should only be called from the postmaster.
*/
void
ResetBackgroundWorkerCrashTimes(void)
{
slist_mutable_iter iter;
slist_foreach_modify(iter, &BackgroundWorkerList)
{
RegisteredBgWorker *rw;
rw = slist_container(RegisteredBgWorker, rw_lnode, iter.cur);
if (rw->rw_worker.bgw_restart_time == BGW_NEVER_RESTART)
{
/*
* Workers marked BGW_NEVER_RESTART shouldn't get relaunched after
* the crash, so forget about them. (If we wait until after the
* crash to forget about them, and they are parallel workers,
* parallel_terminate_count will get incremented after we've
* already zeroed parallel_register_count, which would be bad.)
*/
ForgetBackgroundWorker(&iter);
}
else
{
/*
* The accounting which we do via parallel_register_count and
* parallel_terminate_count would get messed up if a worker marked
* parallel could survive a crash and restart cycle. All such
* workers should be marked BGW_NEVER_RESTART, and thus control
* should never reach this branch.
*/
Assert((rw->rw_worker.bgw_flags & BGWORKER_CLASS_PARALLEL) == 0);
/*
* Allow this worker to be restarted immediately after we finish
* resetting.
*/
rw->rw_crashed_at = 0;
/*
* If there was anyone waiting for it, they're history.
*/
rw->rw_worker.bgw_notify_pid = 0;
}
}
}
#ifdef EXEC_BACKEND
/*
* In EXEC_BACKEND mode, workers use this to retrieve their details from
* shared memory.
*/
BackgroundWorker *
BackgroundWorkerEntry(int slotno)
{
static BackgroundWorker myEntry;
BackgroundWorkerSlot *slot;
Assert(slotno < BackgroundWorkerData->total_slots);
slot = &BackgroundWorkerData->slot[slotno];
Assert(slot->in_use);
/* must copy this in case we don't intend to retain shmem access */
memcpy(&myEntry, &slot->worker, sizeof myEntry);
return &myEntry;
}
#endif
/*
* Complain about the BackgroundWorker definition using error level elevel.
* Return true if it looks ok, false if not (unless elevel >= ERROR, in
* which case we won't return at all in the not-OK case).
*/
static bool
SanityCheckBackgroundWorker(BackgroundWorker *worker, int elevel)
{
/* sanity check for flags */
/*
* We used to support workers not connected to shared memory, but don't
* anymore. Thus this is a required flag now. We're not removing the flag
* for compatibility reasons and because the flag still provides some
* signal when reading code.
*/
if (!(worker->bgw_flags & BGWORKER_SHMEM_ACCESS))
{
ereport(elevel,
(errcode(ERRCODE_INVALID_PARAMETER_VALUE),
errmsg("background worker \"%s\": background workers without shared memory access are not supported",
worker->bgw_name)));
return false;
}
if (worker->bgw_flags & BGWORKER_BACKEND_DATABASE_CONNECTION)
{
if (worker->bgw_start_time == BgWorkerStart_PostmasterStart)
{
ereport(elevel,
(errcode(ERRCODE_INVALID_PARAMETER_VALUE),
errmsg("background worker \"%s\": cannot request database access if starting at postmaster start",
worker->bgw_name)));
return false;
}
/* XXX other checks? */
}
if ((worker->bgw_restart_time < 0 &&
worker->bgw_restart_time != BGW_NEVER_RESTART) ||
(worker->bgw_restart_time > USECS_PER_DAY / 1000))
{
ereport(elevel,
(errcode(ERRCODE_INVALID_PARAMETER_VALUE),
errmsg("background worker \"%s\": invalid restart interval",
worker->bgw_name)));
return false;
}
/*
* Parallel workers may not be configured for restart, because the
* parallel_register_count/parallel_terminate_count accounting can't
* handle parallel workers lasting through a crash-and-restart cycle.
*/
if (worker->bgw_restart_time != BGW_NEVER_RESTART &&
(worker->bgw_flags & BGWORKER_CLASS_PARALLEL) != 0)
{
ereport(elevel,
(errcode(ERRCODE_INVALID_PARAMETER_VALUE),
errmsg("background worker \"%s\": parallel workers may not be configured for restart",
worker->bgw_name)));
return false;
}
/*
* If bgw_type is not filled in, use bgw_name.
*/
if (strcmp(worker->bgw_type, "") == 0)
strcpy(worker->bgw_type, worker->bgw_name);
return true;
}
/*
* Standard SIGTERM handler for background workers
*/
static void
bgworker_die(SIGNAL_ARGS)
{
sigprocmask(SIG_SETMASK, &BlockSig, NULL);
ereport(FATAL,
(errcode(ERRCODE_ADMIN_SHUTDOWN),
errmsg("terminating background worker \"%s\" due to administrator command",
MyBgworkerEntry->bgw_type)));
}
/*
* Start a new background worker
*
* This is the main entry point for background worker, to be called from
* postmaster.
*/
void
StartBackgroundWorker(void)
{
sigjmp_buf local_sigjmp_buf;
BackgroundWorker *worker = MyBgworkerEntry;
bgworker_main_type entrypt;
if (worker == NULL)
elog(FATAL, "unable to find bgworker entry");
IsBackgroundWorker = true;
MyBackendType = B_BG_WORKER;
init_ps_display(worker->bgw_name);
SetProcessingMode(InitProcessing);
/* Apply PostAuthDelay */
if (PostAuthDelay > 0)
pg_usleep(PostAuthDelay * 1000000L);
/*
* Set up signal handlers.
*/
if (worker->bgw_flags & BGWORKER_BACKEND_DATABASE_CONNECTION)
{
/*
* SIGINT is used to signal canceling the current action
*/
pqsignal(SIGINT, StatementCancelHandler);
pqsignal(SIGUSR1, procsignal_sigusr1_handler);
pqsignal(SIGFPE, FloatExceptionHandler);
/* XXX Any other handlers needed here? */
}
else
{
pqsignal(SIGINT, SIG_IGN);
pqsignal(SIGUSR1, SIG_IGN);
pqsignal(SIGFPE, SIG_IGN);
}
pqsignal(SIGTERM, bgworker_die);
/* SIGQUIT handler was already set up by InitPostmasterChild */
pqsignal(SIGHUP, SIG_IGN);
InitializeTimeouts(); /* establishes SIGALRM handler */
pqsignal(SIGPIPE, SIG_IGN);
pqsignal(SIGUSR2, SIG_IGN);
pqsignal(SIGCHLD, SIG_DFL);
/*
* If an exception is encountered, processing resumes here.
*
* We just need to clean up, report the error, and go away.
*/
if (sigsetjmp(local_sigjmp_buf, 1) != 0)
{
/* Since not using PG_TRY, must reset error stack by hand */
error_context_stack = NULL;
/* Prevent interrupts while cleaning up */
HOLD_INTERRUPTS();
/*
* sigsetjmp will have blocked all signals, but we may need to accept
* signals while communicating with our parallel leader. Once we've
* done HOLD_INTERRUPTS() it should be safe to unblock signals.
*/
BackgroundWorkerUnblockSignals();
/* Report the error to the parallel leader and the server log */
EmitErrorReport();
/*
* Do we need more cleanup here? For shmem-connected bgworkers, we
* will call InitProcess below, which will install ProcKill as exit
* callback. That will take care of releasing locks, etc.
*/
/* and go away */
proc_exit(1);
}
/* We can now handle ereport(ERROR) */
PG_exception_stack = &local_sigjmp_buf;
/*
* Create a per-backend PGPROC struct in shared memory, except in the
* EXEC_BACKEND case where this was done in SubPostmasterMain. We must do
* this before we can use LWLocks (and in the EXEC_BACKEND case we already
* had to do some stuff with LWLocks).
*/
#ifndef EXEC_BACKEND
InitProcess();
#endif
/*
* Early initialization.
*/
BaseInit();
/*
* Look up the entry point function, loading its library if necessary.
*/
entrypt = LookupBackgroundWorkerFunction(worker->bgw_library_name,
worker->bgw_function_name);
/*
* Note that in normal processes, we would call InitPostgres here. For a
* worker, however, we don't know what database to connect to, yet; so we
* need to wait until the user code does it via
* BackgroundWorkerInitializeConnection().
*/
/*
* Now invoke the user-defined worker code
*/
entrypt(worker->bgw_main_arg);
/* ... and if it returns, we're done */
proc_exit(0);
}
/*
* Register a new static background worker.
*
* This can only be called directly from postmaster or in the _PG_init
* function of a module library that's loaded by shared_preload_libraries;
* otherwise it will have no effect.
*/
void
RegisterBackgroundWorker(BackgroundWorker *worker)
{
RegisteredBgWorker *rw;
static int numworkers = 0;
if (!IsUnderPostmaster)
ereport(DEBUG1,
(errmsg_internal("registering background worker \"%s\"", worker->bgw_name)));
if (!process_shared_preload_libraries_in_progress &&
strcmp(worker->bgw_library_name, "postgres") != 0)
{
if (!IsUnderPostmaster)
ereport(LOG,
(errcode(ERRCODE_FEATURE_NOT_SUPPORTED),
errmsg("background worker \"%s\": must be registered in shared_preload_libraries",
worker->bgw_name)));
return;
}
if (!SanityCheckBackgroundWorker(worker, LOG))
return;
if (worker->bgw_notify_pid != 0)
{
ereport(LOG,
(errcode(ERRCODE_FEATURE_NOT_SUPPORTED),
errmsg("background worker \"%s\": only dynamic background workers can request notification",
worker->bgw_name)));
return;
}
/*
* Enforce maximum number of workers. Note this is overly restrictive: we
* could allow more non-shmem-connected workers, because these don't count
* towards the MAX_BACKENDS limit elsewhere. For now, it doesn't seem
* important to relax this restriction.
*/
if (++numworkers > max_worker_processes)
{
ereport(LOG,
(errcode(ERRCODE_CONFIGURATION_LIMIT_EXCEEDED),
errmsg("too many background workers"),
errdetail_plural("Up to %d background worker can be registered with the current settings.",
"Up to %d background workers can be registered with the current settings.",
max_worker_processes,
max_worker_processes),
errhint("Consider increasing the configuration parameter \"max_worker_processes\".")));
return;
}
/*
* Copy the registration data into the registered workers list.
*/
rw = malloc(sizeof(RegisteredBgWorker));
if (rw == NULL)
{
ereport(LOG,
(errcode(ERRCODE_OUT_OF_MEMORY),
errmsg("out of memory")));
return;
}
rw->rw_worker = *worker;
rw->rw_backend = NULL;
rw->rw_pid = 0;
rw->rw_child_slot = 0;
rw->rw_crashed_at = 0;
rw->rw_terminate = false;
slist_push_head(&BackgroundWorkerList, &rw->rw_lnode);
}
/*
* Register a new background worker from a regular backend.
*
* Returns true on success and false on failure. Failure typically indicates
* that no background worker slots are currently available.
*
* If handle != NULL, we'll set *handle to a pointer that can subsequently
* be used as an argument to GetBackgroundWorkerPid(). The caller can
* free this pointer using pfree(), if desired.
*/
bool
RegisterDynamicBackgroundWorker(BackgroundWorker *worker,
BackgroundWorkerHandle **handle)
{
int slotno;
bool success = false;
bool parallel;
uint64 generation = 0;
/*
* We can't register dynamic background workers from the postmaster. If
* this is a standalone backend, we're the only process and can't start
* any more. In a multi-process environment, it might be theoretically
* possible, but we don't currently support it due to locking
* considerations; see comments on the BackgroundWorkerSlot data
* structure.
*/
if (!IsUnderPostmaster)
return false;
if (!SanityCheckBackgroundWorker(worker, ERROR))
return false;
parallel = (worker->bgw_flags & BGWORKER_CLASS_PARALLEL) != 0;
LWLockAcquire(BackgroundWorkerLock, LW_EXCLUSIVE);
/*
* If this is a parallel worker, check whether there are already too many
* parallel workers; if so, don't register another one. Our view of
* parallel_terminate_count may be slightly stale, but that doesn't really
* matter: we would have gotten the same result if we'd arrived here
* slightly earlier anyway. There's no help for it, either, since the
* postmaster must not take locks; a memory barrier wouldn't guarantee
* anything useful.
*/
if (parallel && (BackgroundWorkerData->parallel_register_count -
BackgroundWorkerData->parallel_terminate_count) >=
max_parallel_workers)
{
Assert(BackgroundWorkerData->parallel_register_count -
BackgroundWorkerData->parallel_terminate_count <=
MAX_PARALLEL_WORKER_LIMIT);
LWLockRelease(BackgroundWorkerLock);
return false;
}
/*
* Look for an unused slot. If we find one, grab it.
*/
for (slotno = 0; slotno < BackgroundWorkerData->total_slots; ++slotno)
{
BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno];
if (!slot->in_use)
{
memcpy(&slot->worker, worker, sizeof(BackgroundWorker));
slot->pid = InvalidPid; /* indicates not started yet */
slot->generation++;
slot->terminate = false;
generation = slot->generation;
if (parallel)
BackgroundWorkerData->parallel_register_count++;
/*
* Make sure postmaster doesn't see the slot as in use before it
* sees the new contents.
*/
pg_write_barrier();
slot->in_use = true;
success = true;
break;
}
}
LWLockRelease(BackgroundWorkerLock);
/* If we found a slot, tell the postmaster to notice the change. */
if (success)
SendPostmasterSignal(PMSIGNAL_BACKGROUND_WORKER_CHANGE);
/*
* If we found a slot and the user has provided a handle, initialize it.
*/
if (success && handle)
{
*handle = palloc(sizeof(BackgroundWorkerHandle));
(*handle)->slot = slotno;
(*handle)->generation = generation;
}
return success;
}
/*
* Get the PID of a dynamically-registered background worker.
*
* If the worker is determined to be running, the return value will be
* BGWH_STARTED and *pidp will get the PID of the worker process. If the
* postmaster has not yet attempted to start the worker, the return value will
* be BGWH_NOT_YET_STARTED. Otherwise, the return value is BGWH_STOPPED.
*
* BGWH_STOPPED can indicate either that the worker is temporarily stopped
* (because it is configured for automatic restart and exited non-zero),
* or that the worker is permanently stopped (because it exited with exit
* code 0, or was not configured for automatic restart), or even that the
* worker was unregistered without ever starting (either because startup
* failed and the worker is not configured for automatic restart, or because
* TerminateBackgroundWorker was used before the worker was successfully
* started).
*/
BgwHandleStatus
GetBackgroundWorkerPid(BackgroundWorkerHandle *handle, pid_t *pidp)
{
BackgroundWorkerSlot *slot;
pid_t pid;
Assert(handle->slot < max_worker_processes);
slot = &BackgroundWorkerData->slot[handle->slot];
/*
* We could probably arrange to synchronize access to data using memory
* barriers only, but for now, let's just keep it simple and grab the
* lock. It seems unlikely that there will be enough traffic here to
* result in meaningful contention.
*/
LWLockAcquire(BackgroundWorkerLock, LW_SHARED);
/*
* The generation number can't be concurrently changed while we hold the
* lock. The pid, which is updated by the postmaster, can change at any
* time, but we assume such changes are atomic. So the value we read
* won't be garbage, but it might be out of date by the time the caller
* examines it (but that's unavoidable anyway).
*
* The in_use flag could be in the process of changing from true to false,
* but if it is already false then it can't change further.
*/
if (handle->generation != slot->generation || !slot->in_use)
pid = 0;
else
pid = slot->pid;
/* All done. */
LWLockRelease(BackgroundWorkerLock);
if (pid == 0)
return BGWH_STOPPED;
else if (pid == InvalidPid)
return BGWH_NOT_YET_STARTED;
*pidp = pid;
return BGWH_STARTED;
}
/*
* Wait for a background worker to start up.
*
* This is like GetBackgroundWorkerPid(), except that if the worker has not
* yet started, we wait for it to do so; thus, BGWH_NOT_YET_STARTED is never
* returned. However, if the postmaster has died, we give up and return
* BGWH_POSTMASTER_DIED, since it that case we know that startup will not
* take place.
*
* The caller *must* have set our PID as the worker's bgw_notify_pid,
* else we will not be awoken promptly when the worker's state changes.
*/
BgwHandleStatus
WaitForBackgroundWorkerStartup(BackgroundWorkerHandle *handle, pid_t *pidp)
{
BgwHandleStatus status;
int rc;
for (;;)
{
pid_t pid;
CHECK_FOR_INTERRUPTS();
status = GetBackgroundWorkerPid(handle, &pid);
if (status == BGWH_STARTED)
*pidp = pid;
if (status != BGWH_NOT_YET_STARTED)
break;
rc = WaitLatch(MyLatch,
WL_LATCH_SET | WL_POSTMASTER_DEATH, 0,
WAIT_EVENT_BGWORKER_STARTUP);
if (rc & WL_POSTMASTER_DEATH)
{
status = BGWH_POSTMASTER_DIED;
break;
}
ResetLatch(MyLatch);
}
return status;
}
/*
* Wait for a background worker to stop.
*
* If the worker hasn't yet started, or is running, we wait for it to stop
* and then return BGWH_STOPPED. However, if the postmaster has died, we give
* up and return BGWH_POSTMASTER_DIED, because it's the postmaster that
* notifies us when a worker's state changes.
*
* The caller *must* have set our PID as the worker's bgw_notify_pid,
* else we will not be awoken promptly when the worker's state changes.
*/
BgwHandleStatus
WaitForBackgroundWorkerShutdown(BackgroundWorkerHandle *handle)
{
BgwHandleStatus status;
int rc;
for (;;)
{
pid_t pid;
CHECK_FOR_INTERRUPTS();
status = GetBackgroundWorkerPid(handle, &pid);
if (status == BGWH_STOPPED)
break;
rc = WaitLatch(MyLatch,
WL_LATCH_SET | WL_POSTMASTER_DEATH, 0,
WAIT_EVENT_BGWORKER_SHUTDOWN);
if (rc & WL_POSTMASTER_DEATH)
{
status = BGWH_POSTMASTER_DIED;
break;
}
ResetLatch(MyLatch);
}
return status;
}
/*
* Instruct the postmaster to terminate a background worker.
*
* Note that it's safe to do this without regard to whether the worker is
* still running, or even if the worker may already have exited and been
* unregistered.
*/
void
TerminateBackgroundWorker(BackgroundWorkerHandle *handle)
{
BackgroundWorkerSlot *slot;
bool signal_postmaster = false;
Assert(handle->slot < max_worker_processes);
slot = &BackgroundWorkerData->slot[handle->slot];
/* Set terminate flag in shared memory, unless slot has been reused. */
LWLockAcquire(BackgroundWorkerLock, LW_EXCLUSIVE);
if (handle->generation == slot->generation)
{
slot->terminate = true;
signal_postmaster = true;
}
LWLockRelease(BackgroundWorkerLock);
/* Make sure the postmaster notices the change to shared memory. */
if (signal_postmaster)
SendPostmasterSignal(PMSIGNAL_BACKGROUND_WORKER_CHANGE);
}
/*
* Look up (and possibly load) a bgworker entry point function.
*
* For functions contained in the core code, we use library name "postgres"
* and consult the InternalBGWorkers array. External functions are
* looked up, and loaded if necessary, using load_external_function().
*
* The point of this is to pass function names as strings across process
* boundaries. We can't pass actual function addresses because of the
* possibility that the function has been loaded at a different address
* in a different process. This is obviously a hazard for functions in
* loadable libraries, but it can happen even for functions in the core code
* on platforms using EXEC_BACKEND (e.g., Windows).
*
* At some point it might be worthwhile to get rid of InternalBGWorkers[]
* in favor of applying load_external_function() for core functions too;
* but that raises portability issues that are not worth addressing now.
*/
static bgworker_main_type
LookupBackgroundWorkerFunction(const char *libraryname, const char *funcname)
{
/*
* If the function is to be loaded from postgres itself, search the
* InternalBGWorkers array.
*/
if (strcmp(libraryname, "postgres") == 0)
{
int i;
for (i = 0; i < lengthof(InternalBGWorkers); i++)
{
if (strcmp(InternalBGWorkers[i].fn_name, funcname) == 0)
return InternalBGWorkers[i].fn_addr;
}
/* We can only reach this by programming error. */
elog(ERROR, "internal function \"%s\" not found", funcname);
}
/* Otherwise load from external library. */
return (bgworker_main_type)
load_external_function(libraryname, funcname, true, NULL);
}
/*
* Given a PID, get the bgw_type of the background worker. Returns NULL if
* not a valid background worker.
*
* The return value is in static memory belonging to this function, so it has
* to be used before calling this function again. This is so that the caller
* doesn't have to worry about the background worker locking protocol.
*/
const char *
GetBackgroundWorkerTypeByPid(pid_t pid)
{
int slotno;
bool found = false;
static char result[BGW_MAXLEN];
LWLockAcquire(BackgroundWorkerLock, LW_SHARED);
for (slotno = 0; slotno < BackgroundWorkerData->total_slots; slotno++)
{
BackgroundWorkerSlot *slot = &BackgroundWorkerData->slot[slotno];
if (slot->pid > 0 && slot->pid == pid)
{
strcpy(result, slot->worker.bgw_type);
found = true;
break;
}
}
LWLockRelease(BackgroundWorkerLock);
if (!found)
return NULL;
return result;
}
|