summaryrefslogtreecommitdiffstats
path: root/doc/userguide/rules/modbus-keyword.rst
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-19 17:39:49 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-19 17:39:49 +0000
commita0aa2307322cd47bbf416810ac0292925e03be87 (patch)
tree37076262a026c4b48c8a0e84f44ff9187556ca35 /doc/userguide/rules/modbus-keyword.rst
parentInitial commit. (diff)
downloadsuricata-3c02481111c540a7642503dfcf0b62e8c69b6ff0.tar.xz
suricata-3c02481111c540a7642503dfcf0b62e8c69b6ff0.zip
Adding upstream version 1:7.0.3.upstream/1%7.0.3
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'doc/userguide/rules/modbus-keyword.rst')
-rw-r--r--doc/userguide/rules/modbus-keyword.rst131
1 files changed, 131 insertions, 0 deletions
diff --git a/doc/userguide/rules/modbus-keyword.rst b/doc/userguide/rules/modbus-keyword.rst
new file mode 100644
index 0000000..a485c71
--- /dev/null
+++ b/doc/userguide/rules/modbus-keyword.rst
@@ -0,0 +1,131 @@
+Modbus Keyword
+==============
+
+The modbus keyword can be used for matching on various properties of
+Modbus requests.
+
+There are three ways of using this keyword:
+
+* matching on functions properties with the setting "function";
+* matching on directly on data access with the setting "access";
+* matching on unit identifier with the setting "unit" only or with the previous setting "function" or "access".
+
+With the setting **function**, you can match on:
+
+* an action based on a function code field and a sub-function code when applicable;
+* one of three categories of Modbus functions;
+* public functions that are publicly defined (setting "public")
+* user-defined functions (setting "user")
+* reserved functions that are dedicated to proprietary extensions of Modbus (keyword "reserved")
+* one of the two sub-groups of public functions:
+
+ * assigned functions whose definition is already given in the Modbus specification (keyword "assigned");
+ * unassigned functions, which are reserved for future use (keyword "unassigned").
+
+Syntax::
+
+ modbus: function <value>
+ modbus: function <value>, subfunction <value>
+ modbus: function [!] <assigned | unassigned | public | user | reserved | all>
+
+Sign '!' is negation
+
+Examples::
+
+ modbus: function 21 # Write File record function
+ modbus: function 4, subfunction 4 # Force Listen Only Mode (Diagnostics) function
+ modbus: function assigned # defined by Modbus Application Protocol Specification V1.1b3
+ modbus: function public # validated by the Modbus.org community
+ modbus: function user # internal use and not supported by the specification
+ modbus: function reserved # used by some companies for legacy products and not available for public use
+ modbus: function !reserved # every function but reserved function
+
+With the **access** setting, you can match on:
+
+* a type of data access (read or write);
+* one of primary tables access (Discretes Input, Coils, Input Registers and Holding Registers);
+* a range of addresses access;
+* a written value.
+
+Syntax::
+
+ modbus: access <read | write>
+ modbus: access read <discretes | coils | input | holding>
+ modbus: access read <discretes | coils | input | holding>, address <value>
+ modbus: access write < coils | holding>
+ modbus: access write < coils | holding>, address <value>
+ modbus: access write < coils | holding>, address <value>, value <value>
+
+With _<value>_ setting matches on the address or value as it is being
+accessed or written as follows::
+
+ address 100 # exactly address 100
+ address 100<>200 # greater than address 100 and smaller than address 200
+ address >100 # greater than address 100
+ address <100 # smaller than address 100
+
+Examples::
+
+ modbus: access read # Read access
+ modbus: access write # Write access
+ modbus: access read input # Read access to Discretes Input table
+ modbus: access write coils # Write access to Coils table
+ modbus: access read discretes, address <100 # Read access at address smaller than 100 of Discretes Input table
+ modbus: access write holding, address 500, value >200 # Write value greater than 200 at address 500 of Holding Registers table
+
+With the setting **unit**, you can match on:
+
+* a MODBUS slave address of a remote device connected on the sub-network behind a bridge or a gateway. The destination IP address identifies the bridge itself and the bridge uses the MODBUS unit identifier to forward the request to the right slave device.
+
+Syntax::
+
+ modbus: unit <value>
+ modbus: unit <value>, function <value>
+ modbus: unit <value>, function <value>, subfunction <value>
+ modbus: unit <value>, function [!] <assigned | unassigned | public | user | reserved | all>
+ modbus: unit <value>, access <read | write>
+ modbus: unit <value>, access read <discretes | coils | input | holding>
+ modbus: unit <value>, access read <discretes | coils | input | holding>, address <value>
+ modbus: unit <value>, access write < coils | holding>
+ modbus: unit <value>, access write < coils | holding>, address <value>
+ modbus: unit <value>, access write < coils | holding>, address <value>, value <value>
+
+With _<value>_ setting matches on the address or value as it is being
+accessed or written as follows::
+
+ unit 10 # exactly unit identifier 10
+ unit 10<>20 # greater than unit identifier 10 and smaller than unit identifier 20
+ unit >10 # greater than unit identifier 10
+ unit <10 # smaller than unit identifier 10
+
+Examples::
+
+ modbus: unit 10 # Unit identifier 10
+ modbus: unit 10, function 21 # Unit identifier 10 and write File record function
+ modbus: unit 10, function 4, subfunction 4 # Unit identifier 10 and force Listen Only Mode (Diagnostics) function
+ modbus: unit 10, function assigned # Unit identifier 10 and assigned function
+ modbus: unit 10, function !reserved # Unit identifier 10 and every function but reserved function
+ modbus: unit 10, access read # Unit identifier 10 and Read access
+ modbus: unit 10, access write coils # Unit identifier 10 and Write access to Coils table
+ modbus: unit >10, access read discretes, address <100 # Greater than unit identifier 10 and Read access at address smaller than 100 of Discretes Input table
+ modbus: unit 10<>20, access write holding, address 500, value >200 # Greater than unit identifier 10 and smaller than unit identifier 20 and Write value greater than 200 at address 500 of Holding Registers table
+
+(cf. http://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf)
+
+**Note:** Address of read and write are starting at 1. So if your system
+is using a start at 0, you need to add 1 the address values.
+
+**Note:** According to MODBUS Messaging on TCP/IP Implementation Guide
+V1.0b, it is recommended to keep the TCP connection opened with a
+remote device and not to open and close it for each MODBUS/TCP
+transaction. In that case, it is important to set the depth of the
+stream reassembling as unlimited (stream.reassembly.depth: 0)
+
+**Note:** According to MODBUS Messaging on TCP/IP Implementation Guide
+V1.0b, the MODBUS slave device addresses on serial line are assigned from 1 to
+247 (decimal). Address 0 is used as broadcast address.
+
+(cf. http://www.modbus.org/docs/Modbus_Messaging_Implementation_Guide_V1_0b.pdf)
+
+Paper and presentation (in french) on Modbus support are available :
+http://www.ssi.gouv.fr/agence/publication/detection-dintrusion-dans-les-systemes-industriels-suricata-et-le-cas-modbus/