summaryrefslogtreecommitdiffstats
path: root/man/sd_bus_set_server.xml
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-10 20:49:52 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-10 20:49:52 +0000
commit55944e5e40b1be2afc4855d8d2baf4b73d1876b5 (patch)
tree33f869f55a1b149e9b7c2b7e201867ca5dd52992 /man/sd_bus_set_server.xml
parentInitial commit. (diff)
downloadsystemd-55944e5e40b1be2afc4855d8d2baf4b73d1876b5.tar.xz
systemd-55944e5e40b1be2afc4855d8d2baf4b73d1876b5.zip
Adding upstream version 255.4.upstream/255.4
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'man/sd_bus_set_server.xml')
-rw-r--r--man/sd_bus_set_server.xml214
1 files changed, 214 insertions, 0 deletions
diff --git a/man/sd_bus_set_server.xml b/man/sd_bus_set_server.xml
new file mode 100644
index 0000000..cfea163
--- /dev/null
+++ b/man/sd_bus_set_server.xml
@@ -0,0 +1,214 @@
+<?xml version='1.0'?>
+<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
+ "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
+<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->
+
+<refentry id="sd_bus_set_server"
+ xmlns:xi="http://www.w3.org/2001/XInclude">
+
+ <refentryinfo>
+ <title>sd_bus_set_server</title>
+ <productname>systemd</productname>
+ </refentryinfo>
+
+ <refmeta>
+ <refentrytitle>sd_bus_set_server</refentrytitle>
+ <manvolnum>3</manvolnum>
+ </refmeta>
+
+ <refnamediv>
+ <refname>sd_bus_set_server</refname>
+ <refname>sd_bus_is_server</refname>
+ <refname>sd_bus_get_bus_id</refname>
+ <refname>sd_bus_set_bus_client</refname>
+ <refname>sd_bus_is_bus_client</refname>
+ <refname>sd_bus_set_monitor</refname>
+ <refname>sd_bus_is_monitor</refname>
+
+ <refpurpose>Configure connection mode for a bus object</refpurpose>
+ </refnamediv>
+
+ <refsynopsisdiv>
+ <funcsynopsis>
+ <funcsynopsisinfo>#include &lt;systemd/sd-bus.h&gt;</funcsynopsisinfo>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_set_server</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ <paramdef>int <parameter>b</parameter></paramdef>
+ <paramdef>sd_id128_t <parameter>id</parameter></paramdef>
+ </funcprototype>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_is_server</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ </funcprototype>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_get_bus_id</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ <paramdef>sd_id128_t *<parameter>id</parameter></paramdef>
+ </funcprototype>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_set_bus_client</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ <paramdef>int <parameter>b</parameter></paramdef>
+ </funcprototype>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_is_bus_client</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ </funcprototype>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_set_monitor</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ <paramdef>int <parameter>b</parameter></paramdef>
+ </funcprototype>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_is_monitor</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ </funcprototype>
+ </funcsynopsis>
+ </refsynopsisdiv>
+
+ <refsect1>
+ <title>Description</title>
+
+ <para><function>sd_bus_set_server()</function> configures the bus object as a server for direct D-Bus
+ connections. <parameter>b</parameter> enables/disables the server mode. If zero, the server mode is
+ disabled. Otherwise, the server mode is enabled. Configuring a bus object as a server is required to
+ allow establishing direct connections between two peers without going via the D-Bus daemon.
+ <parameter>id</parameter> must contain a 128-bit integer id for the server. If clients add a guid field
+ to their D-Bus address string, the server id must match this guid or the D-Bus authentication handshake
+ will fail. If no specific id is defined for the server,
+ <citerefentry><refentrytitle>sd_id128_randomize</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+ can be used to generate a random id instead.</para>
+
+ <para><function>sd_bus_is_server()</function> returns whether the server mode is enabled for the given
+ bus object.</para>
+
+ <para><function>sd_bus_get_bus_id()</function> stores the D-Bus server id configured using
+ <function>sd_bus_set_server()</function> (for server bus objects) or received during D-Bus authentication
+ (for client bus objects) in <parameter>id</parameter>.</para>
+
+ <para><function>sd_bus_set_bus_client()</function> configures the bus object as a D-Bus daemon client.
+ <parameter>b</parameter> enables/disables the client mode. If zero, the client mode is disabled and the
+ bus object should connect directly to a D-Bus server. Otherwise, the client mode is enabled and the bus
+ object should connect to a D-Bus daemon. When connecting to an existing bus using any of the functions in
+ the <citerefentry><refentrytitle>sd_bus_open</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+ family of functions or any of the functions in the
+ <citerefentry><refentrytitle>sd_bus_default</refentrytitle><manvolnum>3</manvolnum></citerefentry> family
+ of functions, the bus object is automatically configured as a bus client. However, when connecting to a
+ D-Bus daemon by calling
+ <citerefentry><refentrytitle>sd_bus_set_address</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+ followed by
+ <citerefentry><refentrytitle>sd_bus_start</refentrytitle><manvolnum>3</manvolnum></citerefentry>, the bus
+ object should be manually configured as a bus client using <function>sd_bus_set_bus_client()</function>.
+ By default, a bus object is not configured as a D-Bus daemon client.</para>
+
+ <para><function>sd_bus_is_bus_client()</function> returns whether the client mode is enabled/disabled for
+ the given bus object.</para>
+
+ <para><function>sd_bus_set_monitor()</function> configures the bus object as a D-Bus monitor object.
+ <parameter>b</parameter> enables/disables the monitor mode. If zero, the monitor mode is disabled. If
+ non-zero, the monitor mode is enabled. When the monitor mode is enabled, no messages may be sent via the
+ bus object and it may not expose any objects on the bus. To start monitoring messages, call the
+ <function>org.freedesktop.DBus.Monitoring.BecomeMonitor</function> method of the D-Bus daemon and pass
+ a list of matches indicating which messages to intercept. See
+ <ulink url="https://dbus.freedesktop.org/doc/dbus-specification.html#bus-messages-become-monitor">
+ The D-Bus specification</ulink> for more information.</para>
+
+ <para><function>sd_bus_is_monitor()</function> returns whether the monitor mode is enabled/disabled for
+ the given bus object.</para>
+
+ </refsect1>
+
+ <refsect1>
+ <title>Return Value</title>
+
+ <para>On success, <function>sd_bus_set_server()</function>,
+ <function>sd_bus_get_bus_id()</function>, <function>sd_bus_set_bus_client()</function> and
+ <function>sd_bus_set_monitor()</function> return a non-negative integer. On failure, they return a
+ negative errno-style error code.</para>
+
+ <para><function>sd_bus_is_server()</function>, <function>sd_bus_is_bus_client()</function> and
+ <function>sd_bus_is_monitor()</function> return a positive integer when the server or client mode is
+ enabled, respectively. Otherwise, they return zero.</para>
+
+ <refsect2>
+ <title>Errors</title>
+
+ <para>Returned errors may indicate the following problems:</para>
+
+ <variablelist>
+ <varlistentry>
+ <term><constant>-ECHILD</constant></term>
+
+ <listitem><para>The bus connection has been created in a different process, library or module instance.</para>
+
+ <xi:include href="version-info.xml" xpointer="v246"/></listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><constant>-EPERM</constant></term>
+
+ <listitem><para>The bus connection has already been started.</para>
+
+ <xi:include href="version-info.xml" xpointer="v246"/></listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><constant>-ENOPKG</constant></term>
+
+ <listitem><para>The bus cannot be resolved.</para>
+
+ <xi:include href="version-info.xml" xpointer="v246"/></listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><constant>-EINVAL</constant></term>
+
+ <listitem><para>A required parameter was <constant>NULL</constant> or
+ <parameter>b</parameter> was zero and <parameter>id</parameter> did not equal
+ <constant>SD_ID128_NULL</constant>.</para>
+
+ <xi:include href="version-info.xml" xpointer="v246"/></listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><constant>-ENOTCONN</constant></term>
+
+ <listitem><para>The bus is not connected.</para>
+
+ <xi:include href="version-info.xml" xpointer="v246"/></listitem>
+ </varlistentry>
+ </variablelist>
+ </refsect2>
+ </refsect1>
+
+ <xi:include href="libsystemd-pkgconfig.xml" />
+
+ <refsect1>
+ <title>History</title>
+ <para><function>sd_bus_set_server()</function>,
+ <function>sd_bus_is_server()</function>,
+ <function>sd_bus_get_bus_id()</function>,
+ <function>sd_bus_set_bus_client()</function>,
+ <function>sd_bus_is_bus_client()</function>,
+ <function>sd_bus_set_monitor()</function>, and
+ <function>sd_bus_is_monitor()</function> were added in version 246.</para>
+ </refsect1>
+
+ <refsect1>
+ <title>See Also</title>
+
+ <para>
+ <citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
+ <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+ </para>
+ </refsect1>
+
+</refentry>