diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-10 20:49:52 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-10 20:49:52 +0000 |
commit | 55944e5e40b1be2afc4855d8d2baf4b73d1876b5 (patch) | |
tree | 33f869f55a1b149e9b7c2b7e201867ca5dd52992 /man/systemd.net-naming-scheme.xml | |
parent | Initial commit. (diff) | |
download | systemd-55944e5e40b1be2afc4855d8d2baf4b73d1876b5.tar.xz systemd-55944e5e40b1be2afc4855d8d2baf4b73d1876b5.zip |
Adding upstream version 255.4.upstream/255.4
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to '')
-rw-r--r-- | man/systemd.net-naming-scheme.xml | 632 |
1 files changed, 632 insertions, 0 deletions
diff --git a/man/systemd.net-naming-scheme.xml b/man/systemd.net-naming-scheme.xml new file mode 100644 index 0000000..e9c00c9 --- /dev/null +++ b/man/systemd.net-naming-scheme.xml @@ -0,0 +1,632 @@ +<?xml version='1.0'?> +<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN" + "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd"> +<!-- SPDX-License-Identifier: LGPL-2.1-or-later --> + +<refentry id="systemd.net-naming-scheme" xmlns:xi="http://www.w3.org/2001/XInclude"> + <refentryinfo> + <title>systemd.net-naming-scheme</title> + <productname>systemd</productname> + </refentryinfo> + + <refmeta> + <refentrytitle>systemd.net-naming-scheme</refentrytitle> + <manvolnum>7</manvolnum> + </refmeta> + + <refnamediv> + <refname>systemd.net-naming-scheme</refname> + <refpurpose>Network device naming schemes</refpurpose> + </refnamediv> + + <refsect1> + <title>Description</title> + + <para>Network interfaces names and MAC addresses may be generated based on certain stable interface + attributes. This is possible when there is enough information about the device to generate those + attributes and the use of this information is configured. This page describes interface naming, i.e. what + possible names may be generated. Those names are generated by the + <citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry> + builtin <command>net_id</command> and exported as udev properties + (<varname>ID_NET_NAME_ONBOARD=</varname>, <varname>ID_NET_LABEL_ONBOARD=</varname>, + <varname>ID_NET_NAME_PATH=</varname>, <varname>ID_NET_NAME_SLOT=</varname>).</para> + + <para>Names and MAC addresses are derived from various stable device metadata attributes. Newer versions + of udev take more of these attributes into account, improving (and thus possibly changing) the names and + addresses used for the same devices. Different versions of those generation rules are called "naming + schemes". The default naming scheme is chosen at compilation time. Usually this will be the latest + implemented version, but it is also possible to set one of the older versions to preserve + compatibility. This may be useful for example for distributions, which may introduce new versions of + systemd in stable releases without changing the naming scheme. The naming scheme may also be overridden + using the <varname>net.naming-scheme=</varname> kernel command line switch, see + <citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>. + Available naming schemes are described below.</para> + + <para>After the udev properties have been generated, appropriate udev rules may be used to actually rename + devices based on those properties. See the description of <varname>NamePolicy=</varname> and + <varname>MACAddressPolicy=</varname> in + <citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry>.</para> + + <para>Note that while the concept of network interface naming schemes is primarily relevant in the + context of <filename>systemd-udevd.service</filename>, the + <citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry> + container manager also takes it into account when naming network interfaces, see below.</para> + </refsect1> + + <refsect1> + <title>Policies</title> + + <para>All names start with a two-character prefix that signifies the interface type.</para> + + <table> + <title>Two character prefixes based on the type of interface</title> + + <tgroup cols='2'> + <thead> + <row> + <entry>Prefix</entry> + <entry>Description</entry> + </row> + </thead> + <tbody> + <row> + <entry><constant>en</constant></entry> + <entry>Ethernet</entry> + </row> + <row> + <entry><constant>ib</constant></entry> + <entry>InfiniBand</entry> + </row> + <row> + <entry><constant>sl</constant></entry> + <entry>Serial line IP (slip)</entry> + </row> + <row> + <entry><constant>wl</constant></entry> + <entry>Wireless local area network (WLAN)</entry> + </row> + <row> + <entry><constant>ww</constant></entry> + <entry>Wireless wide area network (WWAN)</entry> + </row> + </tbody> + </tgroup> + </table> + + <para>The udev <command>net_id</command> builtin exports the following udev device properties:</para> + + <variablelist> + <varlistentry> + <term><varname>ID_NET_NAME_ONBOARD=<replaceable>prefix</replaceable><constant>o</constant><replaceable>number</replaceable></varname></term> + <term><varname>ID_NET_NAME_ONBOARD=<replaceable>prefix</replaceable><constant>d</constant><replaceable>number</replaceable></varname></term> + + <listitem><para>This name is set based on the numeric ordering information given by the firmware + for on-board devices. Different schemes are used depending on the firmware type, as described in + the table below.</para> + + <table> + <title>On-board naming schemes</title> + + <tgroup cols='2'> + <thead> + <row> + <entry>Format</entry> + <entry>Description</entry> + </row> + </thead> + + <tbody> + <row> + <entry><replaceable>prefix</replaceable><constant>o</constant><replaceable>number</replaceable></entry> + <entry>PCI on-board index</entry> + </row> + + <row> + <entry><replaceable>prefix</replaceable><constant>d</constant><replaceable>number</replaceable></entry> + <entry>Devicetree alias index</entry> + </row> + + </tbody> + </tgroup> + </table> + + <xi:include href="version-info.xml" xpointer="v243"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><varname>ID_NET_LABEL_ONBOARD=<replaceable>prefix</replaceable> <replaceable>label</replaceable></varname></term> + + <listitem><para>This property is set based on textual label given by the firmware for on-board + devices. The name consists of the prefix concatenated with the label. This is only available for + PCI devices. + </para> + + <xi:include href="version-info.xml" xpointer="v243"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><varname>ID_NET_NAME_MAC=<replaceable>prefix</replaceable><constant>x</constant><replaceable>AABBCCDDEEFF</replaceable></varname></term> + + <listitem><para>This name consists of the prefix, letter <constant>x</constant>, and 12 hexadecimal + digits of the MAC address. It is available if the device has a fixed MAC address. Because this name + is based on an attribute of the card itself, it remains "stable" when the device is moved (even + between machines), but will change when the hardware is replaced.</para> + + <xi:include href="version-info.xml" xpointer="v243"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</varname></term> + <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable><constant>v</constant><replaceable>slot</replaceable></varname></term> + <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable><constant>x</constant><replaceable>slot</replaceable></varname></term> + <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></varname></term> + <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</varname></term> + <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>v</constant><replaceable>slot</replaceable></varname></term> + <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>r</constant><replaceable>slot</replaceable></varname></term> + + <listitem><para>This property describes the slot position. Different schemes are used depending on + the bus type, as described in the table below. In case of USB, BCMA, and SR-VIO devices, the full + name consists of the prefix, PCI slot identifier, and USB or BCMA or SR-VIO slot identifier. The + first two parts are denoted as "…" in the table below.</para> + + <table> + <title>Slot naming schemes</title> + + <tgroup cols='2'> + <thead> + <row> + <entry>Format</entry> + <entry>Description</entry> + </row> + </thead> + + <tbody> + <row> + <entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable>] <constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry> + <entry>PCI slot number</entry> + </row> + + <row> + <entry><replaceable>prefix</replaceable> <constant>v</constant><replaceable>slot</replaceable></entry> + <entry>VIO slot number (IBM PowerVM)</entry> + </row> + + <row> + <entry><replaceable>prefix</replaceable> <constant>X</constant><replaceable>number</replaceable></entry> + <entry>VIF interface number (Xen)</entry> + </row> + + <row> + <entry>… <constant>b</constant><replaceable>number</replaceable></entry> + <entry>Broadcom bus (BCMA) core number</entry> + </row> + + <row> + <entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry> + <entry>USB port number chain</entry> + </row> + + <row> + <entry>… <constant>v</constant><replaceable>slot</replaceable></entry> + <entry>SR-VIO slot number</entry> + </row> + + <row> + <entry>… <constant>r</constant><replaceable>slot</replaceable></entry> + <entry>SR-IOV slot number</entry> + </row> + </tbody> + </tgroup> + </table> + + <para>The PCI domain is only prepended when it is not 0. All multi-function PCI devices will carry + the <constant>f<replaceable>function</replaceable></constant> number in the device name, including + the function 0 device. For non-multi-function devices, the number is suppressed if 0. The port name + <replaceable>port_name</replaceable> is used, or the port number + <constant>d</constant><replaceable>dev_port</replaceable> if the name is not known.</para> + + <para>For BCMA devices, the core number is suppressed when 0.</para> + + <para>For USB devices the full chain of port numbers of hubs is composed. If the name gets longer + than the maximum number of 15 characters, the name is not exported. The usual USB configuration + number 1 and interface number 0 values are suppressed.</para> + + <para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of + <constant>v</constant> and the virtual device number, with any leading zeros removed. The bus + number is ignored.</para> + + <para>SR-IOV virtual device representors are named based on the name of the physical device + interface, with a suffix of <constant>r</constant> and the number of the virtual device that + is linked to the particular representor, with any leading zeros removed. The physical port + name and the bus number are ignored.</para> + + <para>In some configurations a parent PCI bridge of a given network controller may be associated + with a slot. In such case we don't generate this device property to avoid possible naming conflicts.</para> + + <xi:include href="version-info.xml" xpointer="v243"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>c</constant><replaceable>bus_id</replaceable></varname></term> + <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>a</constant><replaceable>vendor</replaceable><replaceable>model</replaceable><constant>i</constant><replaceable>instance</replaceable></varname></term> + <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>i</constant><replaceable>address</replaceable><constant>n</constant><replaceable>port_name</replaceable></varname></term> + <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>u</constant><replaceable>port</replaceable>…</varname></term> + <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</varname></term> + <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></varname></term> + <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</varname></term> + + <listitem><para>This property describes the device installation location. Different schemes are + used depending on the bus type, as described in the table below. For BCMA and USB devices, PCI path + information must known, and the full name consists of the prefix, PCI slot identifier, and USB or + BCMA location. The first two parts are denoted as "…" in the table below.</para> + + <table> + <title>Path naming schemes</title> + + <tgroup cols='2'> + <thead> + <row> + <entry>Format</entry> + <entry>Description</entry> + </row> + </thead> + + <tbody> + <row> + <entry><replaceable>prefix</replaceable> <constant>c</constant><replaceable>bus_id</replaceable></entry> + <entry>CCW or grouped CCW device identifier</entry> + </row> + + <row> + <entry><replaceable>prefix</replaceable> <constant>a</constant><replaceable>vendor</replaceable> <replaceable>model</replaceable> <constant>i</constant><replaceable>instance</replaceable></entry> + <entry>ACPI path names for ARM64 platform devices</entry> + </row> + + <row> + <entry><replaceable>prefix</replaceable> <constant>i</constant><replaceable>address</replaceable> <constant>n</constant><replaceable>port_name</replaceable></entry> + <entry>Netdevsim (simulated networking device) device number and port name</entry> + </row> + + <row> + <entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable>] <constant>p</constant><replaceable>bus</replaceable> <constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>phys_port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry> + <entry>PCI geographical location</entry> + </row> + + <row> + <entry>… <constant>b</constant><replaceable>number</replaceable></entry> + <entry>Broadcom bus (BCMA) core number</entry> + </row> + + <row> + <entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry> + <entry>USB port number chain</entry> + </row> + + </tbody> + </tgroup> + </table> + + <para>CCW and grouped CCW devices are found in IBM System Z mainframes. Any leading zeros and + dots are suppressed.</para> + + <para>For PCI, BCMA, and USB devices, the same rules as described above for slot naming are + used.</para> + + <xi:include href="version-info.xml" xpointer="v243"/> + </listitem> + </varlistentry> + </variablelist> + </refsect1> + + <refsect1> + <title>History</title> + + <para>The following "naming schemes" have been defined (which may be chosen at system boot-up time via + the <varname>net.naming-scheme=</varname> kernel command line switch, see above):</para> + + <variablelist> + <varlistentry> + <term><constant>v238</constant></term> + + <listitem><para>This is the naming scheme that was implemented in systemd 238.</para> + + <xi:include href="version-info.xml" xpointer="v243"/></listitem> + </varlistentry> + + <varlistentry> + <term><constant>v239</constant></term> + + <listitem><para>Naming was changed for virtual network interfaces created with SR-IOV and NPAR and + for devices where the PCI network controller device does not have a slot number associated.</para> + + <para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of + <literal>v<replaceable>port</replaceable></literal>, where <replaceable>port</replaceable> is the + virtual device number. Previously those virtual devices were named as if completely independent. + </para> + + <para>The ninth and later NPAR virtual devices are named following the scheme used for the first + eight NPAR partitions. Previously those devices were not renamed and the kernel default + ("eth<replaceable>N</replaceable>") was used.</para> + + <para>Names are also generated for PCI devices where the PCI network controller device does not + have an associated slot number itself, but one of its parents does. Previously those devices were + not renamed and the kernel default was used.</para> + + <xi:include href="version-info.xml" xpointer="v243"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><constant>v240</constant></term> + + <listitem><para>The <literal>ib</literal> prefix and stable names for infiniband devices are + introduced. Previously those devices were not renamed.</para> + + <para>The ACPI index field (used in <varname>ID_NET_NAME_ONBOARD=</varname>) is now also used when + 0.</para> + + <para>A new naming policy <varname>NamePolicy=keep</varname> was introduced. With this policy, if + the network device name was already set by userspace, the device will not be renamed + again. Previously, this naming policy applied implicitly, and now it must be explicitly + requested. Effectively, this means that network devices will be renamed according to the + configuration, even if they have been renamed already, if <constant>keep</constant> is not + specified as the naming policy in the <filename index="false">.link</filename> file. See + <citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry> + for a description of <varname>NamePolicy=</varname>.</para> + + <xi:include href="version-info.xml" xpointer="v243"/></listitem> + </varlistentry> + + <varlistentry> + <term><constant>v241</constant></term> + + <listitem><para><option>MACAddressPolicy=persistent</option> was extended to set MAC addresses + based on the device name. Previously addresses were only based on the + <varname index="false">ID_NET_NAME_*</varname> attributes, which meant that interface names would + never be generated for virtual devices. Now a persistent address will be generated for most + devices, including in particular bridges.</para> + + <para>Note: when userspace does not set a MAC address for a bridge device, the kernel will + initially assign a random address, and then change it when the first device is enslaved to the + bridge. With this naming policy change, bridges get a persistent MAC address based on the bridge + name instead of the first enslaved device.</para> + + <xi:include href="version-info.xml" xpointer="v243"/></listitem> + </varlistentry> + + <varlistentry> + <term><constant>v243</constant></term> + + <listitem><para>Support for renaming netdevsim (simulated networking) devices was added. Previously + those devices were not renamed.</para> + + <para>Previously two-letter interface type prefix was prepended to + <varname>ID_NET_LABEL_ONBOARD=</varname>. This is not done anymore.</para> + + <xi:include href="version-info.xml" xpointer="v243"/></listitem> + </varlistentry> + + <varlistentry> + <term><constant>v245</constant></term> + + <listitem><para>When + <citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry> + derives the name for the host side of the network interface created with + <option>--network-veth</option> from the container name it previously simply truncated the result + at 15 characters if longer (since that's the maximum length for network interface names). From now + on, for any interface name that would be longer than 15 characters the last 4 characters are set to + a 24bit hash value of the full interface name. This way network interface name collisions between + multiple similarly named containers (who only differ in container name suffix) should be less + likely (but still possible, since the 24bit hash value is very small).</para> + + <xi:include href="version-info.xml" xpointer="v245"/></listitem> + </varlistentry> + + <varlistentry> + <term><constant>v247</constant></term> + + <listitem><para>When a PCI slot is associated with a PCI bridge that has multiple child network + controllers, the same value of the <varname>ID_NET_NAME_SLOT</varname> property might be derived + for those controllers. This would cause a naming conflict if the property is selected as the device + name. Now, we detect this situation and don't produce the <varname>ID_NET_NAME_SLOT</varname> + property.</para> + + <xi:include href="version-info.xml" xpointer="v247"/></listitem> + </varlistentry> + + <varlistentry> + <term><constant>v249</constant></term> + + <listitem><para>PCI hotplug slot names for the s390 PCI driver are a hexadecimal representation + of the <filename>function_id</filename> device attribute. This attribute is now used to build the + <varname>ID_NET_NAME_SLOT</varname>. Before that, all slot names were parsed as decimal + numbers, which could either result in an incorrect value of the <varname>ID_NET_NAME_SLOT</varname> + property or none at all.</para> + + <para>Some firmware and hypervisor implementations report unreasonably high numbers for the + on-board index. To prevent the generation of bogus on-board interface names, index numbers greater + than 16381 (2¹⁴-1) were ignored. For s390 PCI devices index values up to 65535 (2¹⁶-1) are valid. + To account for that, the limit was increased to 65535.</para> + + <para>The udev rule <varname>NAME=</varname> replaces <literal>:</literal>, + <literal>/</literal>, and <literal>%</literal> with an underscore (<literal>_</literal>), and + refuses strings which contain only numerics.</para> + + <xi:include href="version-info.xml" xpointer="v249"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><constant>v250</constant></term> + + <listitem><para>Added naming scheme for Xen netfront "vif" interfaces based on the guest side + VIF number set from the Xen config (or the interface index in AWS EC2).</para> + + <xi:include href="version-info.xml" xpointer="v250"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><constant>v251</constant></term> + + <listitem><para>Since version <constant>v247</constant> we no longer set + <varname>ID_NET_NAME_SLOT</varname> if we detect that a PCI device associated with a slot is a PCI + bridge as that would create naming conflict when there are more child devices on that bridge. Now, + this is relaxed and we will use slot information to generate the name based on it but only if + the PCI device has multiple functions. This is safe because distinct function number is a part of + the device name for multifunction devices.</para> + + <xi:include href="version-info.xml" xpointer="v251"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><constant>v252</constant></term> + + <listitem><para>Added naming scheme for platform devices with devicetree aliases.</para> + + <xi:include href="version-info.xml" xpointer="v252"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><constant>v253</constant></term> + + <listitem><para>Set <varname>ID_NET_NAME_PATH</varname> for usb devices not connected via a PCI bus.</para> + + <xi:include href="version-info.xml" xpointer="v253"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><constant>v254</constant></term> + + <listitem><para>Naming was changed for SR-IOV virtual device representors, optionally settable at + compilation time. The <literal>r<replaceable>slot</replaceable></literal> suffix was added to + differentiate SR-IOV virtual device representors attached to a single physical device interface. + Because of a mistake, this scheme was <emphasis>not the the default scheme for systemd version + 254</emphasis>.</para> + + <xi:include href="version-info.xml" xpointer="v255"/> + </listitem> + </varlistentry> + + <varlistentry> + <term><constant>v255</constant></term> + + <listitem><para>Naming was changed for SR-IOV virtual device representors to enable the + change introduced in <constant>v254</constant> by default.</para> + + <xi:include href="version-info.xml" xpointer="v255"/> + </listitem> + </varlistentry> + + </variablelist> + + <para>Note that <constant>latest</constant> may be used to denote the latest scheme known (to this + particular version of systemd).</para> + </refsect1> + + <refsect1> + <title>Examples</title> + + <example> + <title>Using <command>udevadm test-builtin</command> to display device properties</title> + + <programlisting>$ udevadm test-builtin net_id /sys/class/net/enp0s31f6 +... +Using default interface naming scheme 'v243'. +ID_NET_NAMING_SCHEME=v243 +ID_NET_NAME_MAC=enx54ee75cb1dc0 +ID_OUI_FROM_DATABASE=Wistron InfoComm(Kunshan)Co.,Ltd. +ID_NET_NAME_PATH=enp0s31f6 +...</programlisting> + </example> + + <example> + <title>PCI Ethernet card with firmware index "1"</title> + + <programlisting>ID_NET_NAME_ONBOARD=eno1 +ID_NET_NAME_ONBOARD_LABEL=Ethernet Port 1 + </programlisting> + </example> + + <example> + <title>PCI Ethernet card in hotplug slot with firmware index number</title> + + <programlisting># /sys/devices/pci0000:00/0000:00:1c.3/0000:05:00.0/net/ens1 +ID_NET_NAME_MAC=enx000000000466 +ID_NET_NAME_PATH=enp5s0 +ID_NET_NAME_SLOT=ens1</programlisting> + </example> + + <example> + <title>PCI Ethernet multi-function card with 2 ports</title> + + <programlisting># /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.0/net/enp2s0f0 +ID_NET_NAME_MAC=enx78e7d1ea46da +ID_NET_NAME_PATH=enp2s0f0 + +# /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.1/net/enp2s0f1 +ID_NET_NAME_MAC=enx78e7d1ea46dc +ID_NET_NAME_PATH=enp2s0f1</programlisting> + </example> + + <example> + <title>PCI WLAN card</title> + + <programlisting># /sys/devices/pci0000:00/0000:00:1c.1/0000:03:00.0/net/wlp3s0 +ID_NET_NAME_MAC=wlx0024d7e31130 +ID_NET_NAME_PATH=wlp3s0</programlisting> + </example> + + <example> + <title>PCI IB host adapter with 2 ports</title> + + <programlisting># /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.0/net/ibp21s0f0 +ID_NET_NAME_PATH=ibp21s0f0 + +# /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.1/net/ibp21s0f1 +ID_NET_NAME_PATH=ibp21s0f1</programlisting> + </example> + + <example> + <title>USB built-in 3G modem</title> + + <programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.4/2-1.4:1.6/net/wwp0s29u1u4i6 +ID_NET_NAME_MAC=wwx028037ec0200 +ID_NET_NAME_PATH=wwp0s29u1u4i6</programlisting> + </example> + + <example> + <title>USB Android phone</title> + + <programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.2/2-1.2:1.0/net/enp0s29u1u2 +ID_NET_NAME_MAC=enxd626b3450fb5 +ID_NET_NAME_PATH=enp0s29u1u2</programlisting> + </example> + + <example> + <title>s390 grouped CCW interface</title> + + <programlisting># /sys/devices/css0/0.0.0007/0.0.f5f0/group_device/net/encf5f0 +ID_NET_NAME_MAC=enx026d3c00000a +ID_NET_NAME_PATH=encf5f0</programlisting> + </example> + </refsect1> + + <refsect1> + <title>See Also</title> + <para> + <citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry>, + <citerefentry><refentrytitle>udevadm</refentrytitle><manvolnum>8</manvolnum></citerefentry>, + <ulink url="https://systemd.io/PREDICTABLE_INTERFACE_NAMES">Predictable Network Interface Names</ulink>, + <citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry> + </para> + </refsect1> + +</refentry> |