summaryrefslogtreecommitdiffstats
path: root/man/systemd.timer.xml
blob: ad79552ed66dcd904d5a12cd4c33daab109c994f (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
<?xml version='1.0'?>
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
  "http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd">
<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->

<refentry id="systemd.timer" xmlns:xi="http://www.w3.org/2001/XInclude">
  <refentryinfo>
    <title>systemd.timer</title>
    <productname>systemd</productname>
  </refentryinfo>

  <refmeta>
    <refentrytitle>systemd.timer</refentrytitle>
    <manvolnum>5</manvolnum>
  </refmeta>

  <refnamediv>
    <refname>systemd.timer</refname>
    <refpurpose>Timer unit configuration</refpurpose>
  </refnamediv>

  <refsynopsisdiv>
    <para><filename><replaceable>timer</replaceable>.timer</filename></para>
  </refsynopsisdiv>

  <refsect1>
    <title>Description</title>

    <para>A unit configuration file whose name ends in
    <literal>.timer</literal> encodes information about a timer
    controlled and supervised by systemd, for timer-based
    activation.</para>

    <para>This man page lists the configuration options specific to
    this unit type. See
    <citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry>
    for the common options of all unit configuration files. The common
    configuration items are configured in the generic [Unit] and
    [Install] sections. The timer specific configuration options are
    configured in the [Timer] section.</para>

    <para>For each timer file, a matching unit file must exist,
    describing the unit to activate when the timer elapses. By
    default, a service by the same name as the timer (except for the
    suffix) is activated. Example: a timer file
    <filename>foo.timer</filename> activates a matching service
    <filename>foo.service</filename>. The unit to activate may be
    controlled by <varname>Unit=</varname> (see below).</para>

    <para>Note that in case the unit to activate is already active at the time the timer elapses it is not restarted,
    but simply left running. There is no concept of spawning new service instances in this case. Due to this, services
    with <varname>RemainAfterExit=yes</varname> set (which stay around continuously even after the service's main
    process exited) are usually not suitable for activation via repetitive timers, as they will only be activated
    once, and then stay around forever. Target units, which by default do not deactivate on their own, can be
    activated repeatedly by timers by setting <varname>StopWhenUnneeded=yes</varname> on them. This will cause a
    target unit to be stopped immediately after its activation, if it is not a dependency of another running unit.</para>
  </refsect1>

  <refsect1>
    <title>Automatic Dependencies</title>

    <refsect2>
      <title>Implicit Dependencies</title>

      <para>The following dependencies are implicitly added:</para>

      <itemizedlist>
        <listitem><para>Timer units automatically gain a <varname>Before=</varname>
        dependency on the service they are supposed to activate.</para></listitem>
      </itemizedlist>
    </refsect2>

    <refsect2>
      <title>Default Dependencies</title>

      <para>The following dependencies are added unless <varname>DefaultDependencies=no</varname> is set:</para>

      <itemizedlist>
        <listitem><para>Timer units will automatically have dependencies of type <varname>Requires=</varname> and
        <varname>After=</varname> on <filename>sysinit.target</filename>, a dependency of type <varname>Before=</varname>
        on <filename>timers.target</filename>, as well as <varname>Conflicts=</varname> and <varname>Before=</varname> on
        <filename>shutdown.target</filename> to ensure that they are stopped cleanly prior to system shutdown. Only timer
        units involved with early boot or late system shutdown should disable the
        <varname>DefaultDependencies=</varname> option.</para></listitem>

        <listitem><para>Timer units with at least one <varname>OnCalendar=</varname> directive acquire a pair
        of additional <varname>After=</varname> dependencies on <filename>time-set.target</filename> and
        <filename>time-sync.target</filename>, in order to avoid being started before the system clock has
        been correctly set. See
        <citerefentry><refentrytitle>systemd.special</refentrytitle><manvolnum>7</manvolnum></citerefentry>
        for details on these two targets.</para></listitem>
      </itemizedlist>
    </refsect2>
  </refsect1>

  <refsect1>
    <title>Options</title>

    <para>Timer unit files may include [Unit] and [Install] sections, which are described in
    <citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry>.
    </para>

    <para>Timer unit files must include a [Timer] section, which carries
    information about the timer it defines. The options specific to
    the [Timer] section of timer units are the following:</para>

    <variablelist class='unit-directives'>
      <varlistentry>
        <term><varname>OnActiveSec=</varname></term>
        <term><varname>OnBootSec=</varname></term>
        <term><varname>OnStartupSec=</varname></term>
        <term><varname>OnUnitActiveSec=</varname></term>
        <term><varname>OnUnitInactiveSec=</varname></term>

        <listitem><para>Defines monotonic timers relative to different
        starting points:</para>

        <table>
          <title>Settings and their starting points</title>

          <tgroup cols='2'>
            <thead>
              <row>
                <entry>Setting</entry>
                <entry>Meaning</entry>
              </row>
            </thead>
            <tbody>
              <row>
                <entry><varname>OnActiveSec=</varname></entry>
                <entry>Defines a timer relative to the moment the timer unit itself is activated.</entry>
              </row>
              <row>
                <entry><varname>OnBootSec=</varname></entry>
                <entry>Defines a timer relative to when the machine was booted up. In containers, for the system manager instance, this is mapped to <varname>OnStartupSec=</varname>, making both equivalent.</entry>
              </row>
              <row>
                <entry><varname>OnStartupSec=</varname></entry>
                <entry>Defines a timer relative to when the service manager was first started. For system timer units this is very similar to <varname>OnBootSec=</varname> as the system service manager is generally started very early at boot. It's primarily useful when configured in units running in the per-user service manager, as the user service manager is generally started on first login only, not already during boot.</entry>
              </row>
              <row>
                <entry><varname>OnUnitActiveSec=</varname></entry>
                <entry>Defines a timer relative to when the unit the timer unit is activating was last activated.</entry>
              </row>
              <row>
                <entry><varname>OnUnitInactiveSec=</varname></entry>
                <entry>Defines a timer relative to when the unit the timer unit is activating was last deactivated.</entry>
              </row>
            </tbody>
          </tgroup>
        </table>

        <para>Multiple directives may be combined of the same and of different types, in which case the timer
        unit will trigger whenever any of the specified timer expressions elapse. For example, by combining
        <varname>OnBootSec=</varname> and <varname>OnUnitActiveSec=</varname>, it is possible to define a
        timer that elapses in regular intervals and activates a specific service each time. Moreover, both
        monotonic time expressions and <varname>OnCalendar=</varname> calendar expressions may be combined in
        the same timer unit.</para>

        <para>The arguments to the directives are time spans
        configured in seconds. Example: "OnBootSec=50" means 50s after
        boot-up. The argument may also include time units. Example:
        "OnBootSec=5h 30min" means 5 hours and 30 minutes after
        boot-up. For details about the syntax of time spans, see
        <citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>7</manvolnum></citerefentry>.</para>

        <para>If a timer configured with <varname>OnBootSec=</varname>
        or <varname>OnStartupSec=</varname> is already in the past
        when the timer unit is activated, it will immediately elapse
        and the configured unit is started. This is not the case for
        timers defined in the other directives.</para>

        <para>These are monotonic timers, independent of wall-clock time and timezones. If the computer is
        temporarily suspended, the monotonic clock generally pauses, too. Note that if
        <varname>WakeSystem=</varname> is used, a different monotonic clock is selected that continues to
        advance while the system is suspended and thus can be used as the trigger to resume the
        system.</para>

        <para>If the empty string is assigned to any of these options, the list of timers is reset (both
        monotonic timers and <varname>OnCalendar=</varname> timers, see below), and all prior assignments
        will have no effect.</para>

        <para>Note that timers do not necessarily expire at the
        precise time configured with these settings, as they are
        subject to the <varname>AccuracySec=</varname> setting
        below.</para></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>OnCalendar=</varname></term>

        <listitem><para>Defines realtime (i.e. wallclock) timers with calendar event expressions. See
        <citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>7</manvolnum></citerefentry> for
        more information on the syntax of calendar event expressions. Otherwise, the semantics are similar to
        <varname>OnActiveSec=</varname> and related settings.</para>

        <para>Note that timers do not necessarily expire at the precise time configured with this setting, as
        it is subject to the <varname>AccuracySec=</varname> setting below.</para>

        <para>May be specified more than once, in which case the timer unit will trigger whenever any of the
        specified expressions elapse. Moreover calendar timers and monotonic timers (see above) may be
        combined within the same timer unit.</para>

        <para>If the empty string is assigned to any of these options, the list of timers is reset (both
        <varname>OnCalendar=</varname> timers and monotonic timers, see above), and all prior assignments
        will have no effect.</para>

        <para>Note that calendar timers might be triggered at unexpected times if the system's realtime clock
        is not set correctly. Specifically, on systems that lack a battery-buffered Realtime Clock (RTC) it
        might be wise to enable <filename>systemd-time-wait-sync.service</filename> to ensure the clock is
        adjusted to a network time source <emphasis>before</emphasis> the timer event is set up. Timer units
        with at least one <varname>OnCalendar=</varname> expression are automatically ordered after
        <filename>time-sync.target</filename>, which <filename>systemd-time-wait-sync.service</filename> is
        ordered before.</para>

        <para>When a system is temporarily put to sleep (i.e. system suspend or hibernation) the realtime
        clock does not pause. When a calendar timer elapses while the system is sleeping it will not be acted
        on immediately, but once the system is later resumed it will catch up and process all timers that
        triggered while the system was sleeping. Note that if a calendar timer elapsed more than once while
        the system was continuously sleeping the timer will only result in a single service activation. If
        <varname>WakeSystem=</varname> (see below) is enabled a calendar time event elapsing while the system
        is suspended will cause the system to wake up (under the condition the system's hardware supports
        time-triggered wake-up functionality).</para>

        <xi:include href="version-info.xml" xpointer="v197"/></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>AccuracySec=</varname></term>

        <listitem><para>Specify the accuracy the timer shall elapse
        with. Defaults to 1min. The timer is scheduled to elapse
        within a time window starting with the time specified in
        <varname>OnCalendar=</varname>,
        <varname>OnActiveSec=</varname>,
        <varname>OnBootSec=</varname>,
        <varname>OnStartupSec=</varname>,
        <varname>OnUnitActiveSec=</varname> or
        <varname>OnUnitInactiveSec=</varname> and ending the time
        configured with <varname>AccuracySec=</varname> later. Within
        this time window, the expiry time will be placed at a
        host-specific, randomized, but stable position that is
        synchronized between all local timer units. This is done in
        order to optimize power consumption to suppress unnecessary
        CPU wake-ups. To get best accuracy, set this option to
        1us. Note that the timer is still subject to the timer slack
        configured via
        <citerefentry><refentrytitle>systemd-system.conf</refentrytitle><manvolnum>5</manvolnum></citerefentry>'s
        <varname>TimerSlackNSec=</varname> setting. See
        <citerefentry><refentrytitle>prctl</refentrytitle><manvolnum>2</manvolnum></citerefentry>
        for details. To optimize power consumption, make sure to set
        this value as high as possible and as low as
        necessary.</para>

        <para>Note that this setting is primarily a power saving option that allows coalescing CPU
        wake-ups. It should not be confused with <varname>RandomizedDelaySec=</varname> (see below) which
        adds a random value to the time the timer shall elapse next and whose purpose is the opposite: to
        stretch elapsing of timer events over a longer period to reduce workload spikes. For further details
        and explanations and how both settings play together, see below.</para>

        <xi:include href="version-info.xml" xpointer="v209"/></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>RandomizedDelaySec=</varname></term>

        <listitem><para>Delay the timer by a randomly selected, evenly distributed amount of time between 0
        and the specified time value. Defaults to 0, indicating that no randomized delay shall be applied.
        Each timer unit will determine this delay randomly before each iteration, and the delay will simply
        be added on top of the next determined elapsing time, unless modified with
        <varname>FixedRandomDelay=</varname>, see below.</para>

        <para>This setting is useful to stretch dispatching of similarly configured timer events over a
        certain time interval, to prevent them from firing all at the same time, possibly resulting in
        resource congestion.</para>

        <para>Note the relation to <varname>AccuracySec=</varname> above: the latter allows the service
        manager to coalesce timer events within a specified time range in order to minimize wakeups, while
        this setting does the opposite: it stretches timer events over an interval, to make it unlikely that
        they fire simultaneously. If <varname>RandomizedDelaySec=</varname> and
        <varname>AccuracySec=</varname> are used in conjunction, first the randomized delay is added, and
        then the result is possibly further shifted to coalesce it with other timer events happening on the
        system. As mentioned above <varname>AccuracySec=</varname> defaults to 1 minute and
        <varname>RandomizedDelaySec=</varname> to 0, thus encouraging coalescing of timer events. In order to
        optimally stretch timer events over a certain range of time, set
        <varname>AccuracySec=1us</varname> and <varname>RandomizedDelaySec=</varname> to some higher value.
        </para>

        <xi:include href="version-info.xml" xpointer="v229"/></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>FixedRandomDelay=</varname></term>

        <listitem><para>Takes a boolean argument. When enabled, the randomized offset specified by
        <varname>RandomizedDelaySec=</varname> is reused for all firings of the same timer. For a given timer
        unit, the offset depends on the machine ID, user identifier and timer name, which means that it is
        stable between restarts of the manager. This effectively creates a fixed offset for an individual
        timer, reducing the jitter in firings of this timer, while still avoiding firing at the same time as
        other similarly configured timers.</para>

        <para>This setting has no effect if <varname>RandomizedDelaySec=</varname> is set to 0. Defaults to
        <option>false</option>.</para>

        <xi:include href="version-info.xml" xpointer="v247"/></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>OnClockChange=</varname></term>
        <term><varname>OnTimezoneChange=</varname></term>

        <listitem><para>These options take boolean arguments. When true, the service unit will be triggered
        when the system clock (<constant>CLOCK_REALTIME</constant>) jumps relative to the monotonic clock
        (<constant>CLOCK_MONOTONIC</constant>), or when the local system timezone is modified. These options
        can be used alone or in combination with other timer expressions (see above) within the same timer
        unit. These options default to <option>false</option>.</para>

        <xi:include href="version-info.xml" xpointer="v242"/></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>Unit=</varname></term>

        <listitem><para>The unit to activate when this timer elapses.
        The argument is a unit name, whose suffix is not
        <literal>.timer</literal>. If not specified, this value
        defaults to a service that has the same name as the timer
        unit, except for the suffix. (See above.) It is recommended
        that the unit name that is activated and the unit name of the
        timer unit are named identically, except for the
        suffix.</para></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>Persistent=</varname></term>

        <listitem><para>Takes a boolean argument. If true, the time when the service unit was last triggered
        is stored on disk.  When the timer is activated, the service unit is triggered immediately if it
        would have been triggered at least once during the time when the timer was inactive. Such triggering
        is nonetheless subject to the delay imposed by <varname>RandomizedDelaySec=</varname>.
        This is useful to catch up on missed runs of the service when the system was powered down. Note that
        this setting only has an effect on timers configured with <varname>OnCalendar=</varname>. Defaults to
        <option>false</option>.</para>

        <para>Use <command>systemctl clean --what=state </command> on the timer unit to remove the timestamp
        file maintained by this option from disk. In particular, use this command before uninstalling a timer
        unit. See
        <citerefentry><refentrytitle>systemctl</refentrytitle><manvolnum>1</manvolnum></citerefentry> for
        details.</para>

        <xi:include href="version-info.xml" xpointer="v212"/></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>WakeSystem=</varname></term>

        <listitem><para>Takes a boolean argument. If true, an elapsing timer will cause the system to resume
        from suspend, should it be suspended and if the system supports this. Note that this option will only
        make sure the system resumes on the appropriate times, it will not take care of suspending it again
        after any work that is to be done is finished. Defaults to
        <option>false</option>.</para>

        <para>Note that this functionality requires privileges and is thus generally only available in the
        system service manager.</para>

        <para>Note that behaviour of monotonic clock timers (as configured with
        <varname>OnActiveSec=</varname>, <varname>OnBootSec=</varname>, <varname>OnStartupSec=</varname>,
        <varname>OnUnitActiveSec=</varname>, <varname>OnUnitInactiveSec=</varname>, see above) is altered
        depending on this option. If false, a monotonic clock is used that is paused during system suspend
        (<constant>CLOCK_MONOTONIC</constant>), if true a different monotonic clock is used that continues
        advancing during system suspend (<constant>CLOCK_BOOTTIME</constant>), see
        <citerefentry><refentrytitle>clock_getres</refentrytitle><manvolnum>2</manvolnum></citerefentry> for
        details.</para>

        <xi:include href="version-info.xml" xpointer="v212"/></listitem>
      </varlistentry>

      <varlistentry>
        <term><varname>RemainAfterElapse=</varname></term>

        <listitem><para>Takes a boolean argument. If true, a timer will stay loaded, and its state remains
        queryable even after it elapsed and the associated unit (as configured with <varname>Unit=</varname>,
        see above) deactivated again. If false, an elapsed timer unit that cannot elapse anymore is unloaded
        once its associated unit deactivated again. Turning this off is particularly useful for transient
        timer units. Note that this setting has an effect when repeatedly starting a timer unit: if
        <varname>RemainAfterElapse=</varname> is on, starting the timer a second time has no effect. However,
        if <varname>RemainAfterElapse=</varname> is off and the timer unit was already unloaded, it can be
        started again, and thus the service can be triggered multiple times. Defaults to
        <option>true</option>.</para>

        <xi:include href="version-info.xml" xpointer="v229"/></listitem>
      </varlistentry>
    </variablelist>

    <xi:include href="systemd.service.xml" xpointer="shared-unit-options" />
  </refsect1>

  <refsect1>
      <title>See Also</title>
      <para>Environment variables with details on the trigger will be set for triggered units. See the
      <literal>Environment Variables Set or Propagated by the Service Manager</literal> section in
      <citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry>
      for more details.</para>
      <para><simplelist type="inline">
        <member><citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
        <member><citerefentry><refentrytitle>systemctl</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
        <member><citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry></member>
        <member><citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry></member>
        <member><citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>7</manvolnum></citerefentry></member>
        <member><citerefentry><refentrytitle>systemd.directives</refentrytitle><manvolnum>7</manvolnum></citerefentry></member>
        <member><citerefentry><refentrytitle>systemd-system.conf</refentrytitle><manvolnum>5</manvolnum></citerefentry></member>
        <member><citerefentry><refentrytitle>prctl</refentrytitle><manvolnum>2</manvolnum></citerefentry></member>
      </simplelist></para>
  </refsect1>

</refentry>