1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
|
.\" Man page generated from reStructuredText.
.
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.TH "RNDC-CONFGEN" "8" "@RELEASE_DATE@" "@PACKAGE_VERSION@" "BIND 9"
.SH NAME
rndc-confgen \- rndc key generation tool
.SH SYNOPSIS
.sp
\fBrndc\-confgen\fP [\fB\-a\fP] [\fB\-A\fP algorithm] [\fB\-b\fP keysize] [\fB\-c\fP keyfile] [\fB\-h\fP] [\fB\-k\fP keyname] [\fB\-p\fP port] [\fB\-s\fP address] [\fB\-t\fP chrootdir] [\fB\-u\fP user]
.SH DESCRIPTION
.sp
\fBrndc\-confgen\fP generates configuration files for \fI\%rndc\fP\&. It can be
used as a convenient alternative to writing the \fI\%rndc.conf\fP file and
the corresponding \fBcontrols\fP and \fBkey\fP statements in \fI\%named.conf\fP
by hand. Alternatively, it can be run with the \fI\%\-a\fP option to set up a
\fBrndc.key\fP file and avoid the need for a \fI\%rndc.conf\fP file and a
\fBcontrols\fP statement altogether.
.SH OPTIONS
.INDENT 0.0
.TP
.B \-a
This option sets automatic \fI\%rndc\fP configuration, which creates a file
\fB@sysconfdir@/rndc.key\fP that is read by both \fI\%rndc\fP and \fI\%named\fP on startup.
The \fBrndc.key\fP file defines a default command channel and
authentication key allowing \fI\%rndc\fP to communicate with \fI\%named\fP on
the local host with no further configuration.
.sp
If a more elaborate configuration than that generated by
\fI\%rndc\-confgen \-a\fP is required, for example if rndc is to be used
remotely, run \fBrndc\-confgen\fP without the \fI\%\-a\fP option
and set up \fI\%rndc.conf\fP and \fI\%named.conf\fP as directed.
.UNINDENT
.INDENT 0.0
.TP
.B \-A algorithm
This option specifies the algorithm to use for the TSIG key. Available choices
are: hmac\-md5, hmac\-sha1, hmac\-sha224, hmac\-sha256, hmac\-sha384, and
hmac\-sha512. The default is hmac\-sha256.
.UNINDENT
.INDENT 0.0
.TP
.B \-b keysize
This option specifies the size of the authentication key in bits. The size must be between
1 and 512 bits; the default is the hash size.
.UNINDENT
.INDENT 0.0
.TP
.B \-c keyfile
This option is used with the \fI\%\-a\fP option to specify an alternate location for
\fBrndc.key\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-h
This option prints a short summary of the options and arguments to
\fBrndc\-confgen\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-k keyname
This option specifies the key name of the \fI\%rndc\fP authentication key. This must be a
valid domain name. The default is \fBrndc\-key\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-p port
This option specifies the command channel port where \fI\%named\fP listens for
connections from \fI\%rndc\fP\&. The default is 953.
.UNINDENT
.INDENT 0.0
.TP
.B \-q
This option prevets printing the written path in automatic configuration mode.
.UNINDENT
.INDENT 0.0
.TP
.B \-s address
This option specifies the IP address where \fI\%named\fP listens for command\-channel
connections from \fI\%rndc\fP\&. The default is the loopback address
127.0.0.1.
.UNINDENT
.INDENT 0.0
.TP
.B \-t chrootdir
This option is used with the \fI\%\-a\fP option to specify a directory where \fI\%named\fP
runs chrooted. An additional copy of the \fBrndc.key\fP is
written relative to this directory, so that it is found by the
chrooted \fI\%named\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-u user
This option is used with the \fI\%\-a\fP option to set the owner of the generated \fBrndc.key\fP file.
If \fI\%\-t\fP is also specified, only the file in the chroot
area has its owner changed.
.UNINDENT
.SH EXAMPLES
.sp
To allow \fI\%rndc\fP to be used with no manual configuration, run:
.sp
\fBrndc\-confgen \-a\fP
.sp
To print a sample \fI\%rndc.conf\fP file and the corresponding \fBcontrols\fP and
\fBkey\fP statements to be manually inserted into \fI\%named.conf\fP, run:
.sp
\fBrndc\-confgen\fP
.SH SEE ALSO
.sp
\fI\%rndc(8)\fP, \fI\%rndc.conf(5)\fP, \fI\%named(8)\fP, BIND 9 Administrator Reference Manual.