summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-class-led-flash
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-07 18:49:45 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-07 18:49:45 +0000
commit2c3c1048746a4622d8c89a29670120dc8fab93c4 (patch)
tree848558de17fb3008cdf4d861b01ac7781903ce39 /Documentation/ABI/testing/sysfs-class-led-flash
parentInitial commit. (diff)
downloadlinux-2c3c1048746a4622d8c89a29670120dc8fab93c4.tar.xz
linux-2c3c1048746a4622d8c89a29670120dc8fab93c4.zip
Adding upstream version 6.1.76.upstream/6.1.76
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-led-flash')
-rw-r--r--Documentation/ABI/testing/sysfs-class-led-flash89
1 files changed, 89 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-led-flash b/Documentation/ABI/testing/sysfs-class-led-flash
new file mode 100644
index 000000000..11e5677c3
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-class-led-flash
@@ -0,0 +1,89 @@
+What: /sys/class/leds/<led>/flash_brightness
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Set the brightness of this LED in the flash strobe mode, in
+ microamperes. The file is created only for the flash LED devices
+ that support setting flash brightness.
+
+ The value is between 0 and
+ /sys/class/leds/<led>/max_flash_brightness.
+
+What: /sys/class/leds/<led>/max_flash_brightness
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Maximum brightness level for this LED in the flash strobe mode,
+ in microamperes.
+
+What: /sys/class/leds/<led>/flash_timeout
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Hardware timeout for flash, in microseconds. The flash strobe
+ is stopped after this period of time has passed from the start
+ of the strobe. The file is created only for the flash LED
+ devices that support setting flash timeout.
+
+What: /sys/class/leds/<led>/max_flash_timeout
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Maximum flash timeout for this LED, in microseconds.
+
+What: /sys/class/leds/<led>/flash_strobe
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Flash strobe state. When written with 1 it triggers flash strobe
+ and when written with 0 it turns the flash off.
+
+ On read 1 means that flash is currently strobing and 0 means
+ that flash is off.
+
+What: /sys/class/leds/<led>/flash_fault
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Space separated list of flash faults that may have occurred.
+ Flash faults are re-read after strobing the flash. Possible
+ flash faults:
+
+ * led-over-voltage
+ flash controller voltage to the flash LED
+ has exceeded the limit specific to the flash controller
+ * flash-timeout-exceeded
+ the flash strobe was still on when
+ the timeout set by the user has expired; not all flash
+ controllers may set this in all such conditions
+ * controller-over-temperature
+ the flash controller has
+ overheated
+ * controller-short-circuit
+ the short circuit protection
+ of the flash controller has been triggered
+ * led-power-supply-over-current
+ current in the LED power
+ supply has exceeded the limit specific to the flash
+ controller
+ * indicator-led-fault
+ the flash controller has detected
+ a short or open circuit condition on the indicator LED
+ * led-under-voltage
+ flash controller voltage to the flash
+ LED has been below the minimum limit specific to
+ the flash
+ * controller-under-voltage
+ the input voltage of the flash
+ controller is below the limit under which strobing the
+ flash at full current will not be possible;
+ the condition persists until this flag is no longer set
+ * led-over-temperature
+ the temperature of the LED has exceeded
+ its allowed upper limit