diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-07 18:49:45 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-07 18:49:45 +0000 |
commit | 2c3c1048746a4622d8c89a29670120dc8fab93c4 (patch) | |
tree | 848558de17fb3008cdf4d861b01ac7781903ce39 /net/hsr/Kconfig | |
parent | Initial commit. (diff) | |
download | linux-2c3c1048746a4622d8c89a29670120dc8fab93c4.tar.xz linux-2c3c1048746a4622d8c89a29670120dc8fab93c4.zip |
Adding upstream version 6.1.76.upstream/6.1.76
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'net/hsr/Kconfig')
-rw-r--r-- | net/hsr/Kconfig | 40 |
1 files changed, 40 insertions, 0 deletions
diff --git a/net/hsr/Kconfig b/net/hsr/Kconfig new file mode 100644 index 000000000..1b048c17b --- /dev/null +++ b/net/hsr/Kconfig @@ -0,0 +1,40 @@ +# SPDX-License-Identifier: GPL-2.0-only +# +# IEC 62439-3 High-availability Seamless Redundancy +# + +config HSR + tristate "High-availability Seamless Redundancy (HSR & PRP)" + help + This enables IEC 62439 defined High-availability Seamless + Redundancy (HSR) and Parallel Redundancy Protocol (PRP). + + If you say Y here, then your Linux box will be able to act as a + DANH ("Doubly attached node implementing HSR") or DANP ("Doubly + attached node implementing PRP"). For this to work, your Linux box + needs (at least) two physical Ethernet interfaces. + + For DANH, it must be connected as a node in a ring network together + with other HSR capable nodes. All Ethernet frames sent over the HSR + device will be sent in both directions on the ring (over both slave + ports), giving a redundant, instant fail-over network. Each HSR node + in the ring acts like a bridge for HSR frames, but filters frames + that have been forwarded earlier. + + For DANP, it must be connected as a node connecting to two + separate networks over the two slave interfaces. Like HSR, Ethernet + frames sent over the PRP device will be sent to both networks giving + a redundant, instant fail-over network. Unlike HSR, PRP networks + can have Singly Attached Nodes (SAN) such as PC, printer, bridges + etc and will be able to communicate with DANP nodes. + + This code is a "best effort" to comply with the HSR standard as + described in IEC 62439-3:2010 (HSRv0) and IEC 62439-3:2012 (HSRv1), + and PRP standard described in IEC 62439-4:2012 (PRP), but no + compliancy tests have been made. Use iproute2 to select the protocol + you would like to use. + + You need to perform any and all necessary tests yourself before + relying on this code in a safety critical system! + + If unsure, say N. |