+Kernel driver inspur-ipsps1
+===========================
+
+Supported chips:
+
+ * Inspur Power System power supply unit
+
+Author: John Wang <wangzqbj@inspur.com>
+
+Description
+-----------
+
+This driver supports Inspur Power System power supplies. This driver
+is a client to the core PMBus driver.
+
+Usage Notes
+-----------
+
+This driver does not auto-detect devices. You will have to instantiate the
+devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
+details.
+
+Sysfs entries
+-------------
+
+The following attributes are supported:
+
+======================= ======================================================
+curr1_input Measured input current
+curr1_label "iin"
+curr1_max Maximum current
+curr1_max_alarm Current high alarm
+curr2_input Measured output current in mA.
+curr2_label "iout1"
+curr2_crit Critical maximum current
+curr2_crit_alarm Current critical high alarm
+curr2_max Maximum current
+curr2_max_alarm Current high alarm
+
+fan1_alarm Fan 1 warning.
+fan1_fault Fan 1 fault.
+fan1_input Fan 1 speed in RPM.
+
+in1_alarm Input voltage under-voltage alarm.
+in1_input Measured input voltage in mV.
+in1_label "vin"
+in2_input Measured output voltage in mV.
+in2_label "vout1"
+in2_lcrit Critical minimum output voltage
+in2_lcrit_alarm Output voltage critical low alarm
+in2_max Maximum output voltage
+in2_max_alarm Output voltage high alarm
+in2_min Minimum output voltage
+in2_min_alarm Output voltage low alarm
+
+power1_alarm Input fault or alarm.
+power1_input Measured input power in uW.
+power1_label "pin"
+power1_max Input power limit
+power2_max_alarm Output power high alarm
+power2_max Output power limit
+power2_input Measured output power in uW.
+power2_label "pout"
+
+temp[1-3]_input Measured temperature
+temp[1-2]_max Maximum temperature
+temp[1-3]_max_alarm Temperature high alarm
+
+vendor Manufacturer name
+model Product model
+part_number Product part number
+serial_number Product serial number
+fw_version Firmware version
+hw_version Hardware version
+mode Work mode. Can be set to active or
+ standby, when set to standby, PSU will
+ automatically switch between standby
+ and redundancy mode.
+======================= ======================================================