1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
|
What: /sys/bus/counter/devices/counterX/countY/count
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count data of Count Y represented as a string.
What: /sys/bus/counter/devices/counterX/countY/capture
KernelVersion: 6.1
Contact: linux-iio@vger.kernel.org
Description:
Historical capture of the Count Y count data.
What: /sys/bus/counter/devices/counterX/countY/ceiling
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count value ceiling for Count Y. This is the upper limit for the
respective counter.
What: /sys/bus/counter/devices/counterX/countY/floor
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count value floor for Count Y. This is the lower limit for the
respective counter.
What: /sys/bus/counter/devices/counterX/countY/count_mode
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count mode for channel Y. The ceiling and floor values for
Count Y are used by the count mode where required. The following
count modes are available:
normal:
Counting is continuous in either direction.
range limit:
An upper or lower limit is set, mimicking limit switches
in the mechanical counterpart. The upper limit is set to
the Count Y ceiling value, while the lower limit is set
to the Count Y floor value. The counter freezes at
count = ceiling when counting up, and at count = floor
when counting down. At either of these limits, the
counting is resumed only when the count direction is
reversed.
non-recycle:
The counter is disabled whenever a counter overflow or
underflow takes place. The counter is re-enabled when a
new count value is loaded to the counter via a preset
operation or direct write.
modulo-n:
A count value boundary is set between the Count Y floor
value and the Count Y ceiling value. The counter is
reset to the Count Y floor value at count = ceiling when
counting up, while the counter is set to the Count Y
ceiling value at count = floor when counting down; the
counter does not freeze at the boundary points, but
counts continuously throughout.
What: /sys/bus/counter/devices/counterX/countY/count_mode_available
What: /sys/bus/counter/devices/counterX/countY/error_noise_available
What: /sys/bus/counter/devices/counterX/countY/function_available
What: /sys/bus/counter/devices/counterX/countY/prescaler_available
What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Discrete set of available values for the respective Count Y
configuration are listed in this file. Values are delimited by
newline characters.
What: /sys/bus/counter/devices/counterX/countY/direction
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the count direction of Count
Y. Two count directions are available: forward and backward.
Some counter devices are able to determine the direction of
their counting. For example, quadrature encoding counters can
determine the direction of movement by evaluating the leading
phase of the respective A and B quadrature encoding signals.
This attribute exposes such count directions.
What: /sys/bus/counter/devices/counterX/countY/enable
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Whether channel Y counter is enabled. Valid attribute values are
boolean.
This attribute is intended to serve as a pause/unpause mechanism
for Count Y. Suppose a counter device is used to count the total
movement of a conveyor belt: this attribute allows an operator
to temporarily pause the counter, service the conveyor belt,
and then finally unpause the counter to continue where it had
left off.
What: /sys/bus/counter/devices/counterX/countY/error_noise
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates whether excessive noise is
present at the channel Y counter inputs.
What: /sys/bus/counter/devices/counterX/countY/function
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count function mode of Count Y; count function evaluation is
triggered by conditions specified by the Count Y signalZ_action
attributes. The following count functions are available:
increase:
Accumulated count is incremented.
decrease:
Accumulated count is decremented.
pulse-direction:
Rising edges on signal A updates the respective count.
The input level of signal B determines direction.
quadrature x1 a:
If direction is forward, rising edges on quadrature pair
signal A updates the respective count; if the direction
is backward, falling edges on quadrature pair signal A
updates the respective count. Quadrature encoding
determines the direction.
quadrature x1 b:
If direction is forward, rising edges on quadrature pair
signal B updates the respective count; if the direction
is backward, falling edges on quadrature pair signal B
updates the respective count. Quadrature encoding
determines the direction.
quadrature x2 a:
Any state transition on quadrature pair signal A updates
the respective count. Quadrature encoding determines the
direction.
quadrature x2 b:
Any state transition on quadrature pair signal B updates
the respective count. Quadrature encoding determines the
direction.
quadrature x4:
Any state transition on either quadrature pair signals
updates the respective count. Quadrature encoding
determines the direction.
What: /sys/bus/counter/devices/counterX/countY/name
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the device-specific name of
Count Y. If possible, this should match the name of the
respective channel as it appears in the device datasheet.
What: /sys/bus/counter/devices/counterX/countY/prescaler
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Configure the prescaler value associated with Count Y.
On the FlexTimer, the counter clock source passes through a
prescaler (i.e. a counter). This acts like a clock
divider.
What: /sys/bus/counter/devices/counterX/countY/preset
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
If the counter device supports preset registers -- registers
used to load counter channels to a set count upon device-defined
preset operation trigger events -- the preset count for channel
Y is provided by this attribute.
What: /sys/bus/counter/devices/counterX/countY/preset_enable
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Whether channel Y counter preset operation is enabled. Valid
attribute values are boolean.
What: /sys/bus/counter/devices/counterX/countY/signalZ_action
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Action mode of Count Y for Signal Z. This attribute indicates
the condition of Signal Z that triggers the count function
evaluation for Count Y. The following action modes are
available:
none:
Signal does not trigger the count function. In
Pulse-Direction count function mode, this Signal is
evaluated as Direction.
rising edge:
Low state transitions to high state.
falling edge:
High state transitions to low state.
both edges:
Any state transition.
What: /sys/bus/counter/devices/counterX/countY/num_overflows
KernelVersion: 6.1
Contact: linux-iio@vger.kernel.org
Description:
This attribute indicates the number of overflows of count Y.
What: /sys/bus/counter/devices/counterX/countY/capture_component_id
What: /sys/bus/counter/devices/counterX/countY/ceiling_component_id
What: /sys/bus/counter/devices/counterX/countY/floor_component_id
What: /sys/bus/counter/devices/counterX/countY/count_mode_component_id
What: /sys/bus/counter/devices/counterX/countY/direction_component_id
What: /sys/bus/counter/devices/counterX/countY/enable_component_id
What: /sys/bus/counter/devices/counterX/countY/error_noise_component_id
What: /sys/bus/counter/devices/counterX/countY/prescaler_component_id
What: /sys/bus/counter/devices/counterX/countY/preset_component_id
What: /sys/bus/counter/devices/counterX/countY/preset_enable_component_id
What: /sys/bus/counter/devices/counterX/countY/signalZ_action_component_id
What: /sys/bus/counter/devices/counterX/countY/num_overflows_component_id
What: /sys/bus/counter/devices/counterX/signalY/cable_fault_component_id
What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
What: /sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
What: /sys/bus/counter/devices/counterX/signalY/polarity_component_id
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
What: /sys/bus/counter/devices/counterX/signalY/frequency_component_id
KernelVersion: 5.16
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the component ID of the
respective extension or Synapse.
What: /sys/bus/counter/devices/counterX/countY/spike_filter_ns
KernelVersion: 5.14
Contact: linux-iio@vger.kernel.org
Description:
If the counter device supports programmable spike filter this
attribute indicates the value in nanoseconds where noise pulses
shorter or equal to configured value are ignored. Value 0 means
filter is disabled.
What: /sys/bus/counter/devices/counterX/events_queue_size
KernelVersion: 5.16
Contact: linux-iio@vger.kernel.org
Description:
Size of the Counter events queue in number of struct
counter_event data structures. The number of elements will be
rounded-up to a power of 2.
What: /sys/bus/counter/devices/counterX/name
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the device-specific name of
the Counter. This should match the name of the device as it
appears in its respective datasheet.
What: /sys/bus/counter/devices/counterX/num_counts
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the total number of Counts
belonging to the Counter.
What: /sys/bus/counter/devices/counterX/num_signals
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the total number of Signals
belonging to the Counter.
What: /sys/bus/counter/devices/counterX/signalY/cable_fault
KernelVersion: 5.7
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates whether a differential
encoder cable fault (not connected or loose wires) is detected
for the respective channel of Signal Y. Valid attribute values
are boolean. Detection must first be enabled via the
corresponding cable_fault_enable attribute.
What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable
KernelVersion: 5.7
Contact: linux-iio@vger.kernel.org
Description:
Whether detection of differential encoder cable faults for the
respective channel of Signal Y is enabled. Valid attribute
values are boolean.
What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler
KernelVersion: 5.7
Contact: linux-iio@vger.kernel.org
Description:
Filter clock factor for input Signal Y. This prescaler value
affects the inputs of both quadrature pair signals.
What: /sys/bus/counter/devices/counterX/signalY/index_polarity
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Active level of index input Signal Y; irrelevant in
non-synchronous load mode.
What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Discrete set of available values for the respective Signal Y
configuration are listed in this file.
What: /sys/bus/counter/devices/counterX/signalY/polarity
KernelVersion: 6.1
Contact: linux-iio@vger.kernel.org
Description:
Active level of Signal Y. The following polarity values are
available:
positive:
Signal high state considered active level (rising edge).
negative:
Signal low state considered active level (falling edge).
What: /sys/bus/counter/devices/counterX/signalY/name
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the device-specific name of
Signal Y. If possible, this should match the name of the
respective signal as it appears in the device datasheet.
What: /sys/bus/counter/devices/counterX/signalY/signal
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Signal level state of Signal Y. The following signal level
states are available:
low:
Low level state.
high:
High level state.
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Configure the counter associated with Signal Y for
non-synchronous or synchronous load mode. Synchronous load mode
cannot be selected in non-quadrature (Pulse-Direction) clock
mode.
non-synchronous:
A logic low level is the active level at this index
input. The index function (as enabled via preset_enable)
is performed directly on the active level of the index
input.
synchronous:
Intended for interfacing with encoder Index output in
quadrature clock mode. The active level is configured
via index_polarity. The index function (as enabled via
preset_enable) is performed synchronously with the
quadrature clock on the active level of the index input.
What: /sys/bus/counter/devices/counterX/signalY/frequency
KernelVersion: 6.1
Contact: linux-iio@vger.kernel.org
Description: