+What: /sys/bus/iio/devices/iio:deviceX/ac_excitation_en
+KernelVersion:
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute, if available, is used to enable the AC
+ excitation mode found on some converters. In ac excitation mode,
+ the polarity of the excitation voltage is reversed on
+ alternate cycles, to eliminate DC errors.
+
+What: /sys/bus/iio/devices/iio:deviceX/bridge_switch_en
+KernelVersion:
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute, if available, is used to close or open the
+ bridge power down switch found on some converters.
+ In bridge applications, such as strain gauges and load cells,
+ the bridge itself consumes the majority of the current in the
+ system. To minimize the current consumption of the system,
+ the bridge can be disconnected (when it is not being used
+ using the bridge_switch_en attribute.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration
+KernelVersion:
+Contact: linux-iio@vger.kernel.org
+Description:
+ Initiates the system calibration procedure. This is done on a
+ single channel at a time. Write '1' to start the calibration.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw
+KernelVersion:
+Contact: linux-iio@vger.kernel.org
+Description:
+ Measure voltage from AIN2 pin connected to AIN(+)
+ and AIN(-) shorted.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available
+KernelVersion:
+Contact: linux-iio@vger.kernel.org
+Description:
+ Reading returns a list with the possible calibration modes.
+ There are two available options:
+ "zero_scale" - calibrate to zero scale
+ "full_scale" - calibrate to full scale
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode
+KernelVersion:
+Contact: linux-iio@vger.kernel.org
+Description:
+ Sets up the calibration mode used in the system calibration
+ procedure. Reading returns the current calibration mode.
+ Writing sets the system calibration mode.