blob: 85f9a00f143e154ec77197cc283e41b82ce51310 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
|
#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/scripts/common.sh
source $rootdir/test/nvmf/common.sh
rpc_py="$rootdir/scripts/rpc.py"
nvmftestinit
if [[ $CONFIG_FIO_PLUGIN != y ]]; then
echo "FIO not available"
exit 1
fi
timing_enter start_nvmf_tgt
"${NVMF_APP[@]}" -m 0xF &
nvmfpid=$!
trap 'process_shm --id $NVMF_APP_SHM_ID; nvmftestfini; exit 1' SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
timing_exit start_nvmf_tgt
$rpc_py bdev_malloc_create 64 512 -b Malloc1
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc1
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
PLUGIN_DIR=$rootdir/examples/nvme/fio_plugin
# Test fio_plugin as host with malloc backend
fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
# second test mocking multiple SGL elements
fio_nvme $PLUGIN_DIR/mock_sgl_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode1
if [ $RUN_NIGHTLY -eq 1 ]; then
# Test fio_plugin as host with nvme lvol backend
bdfs=$(get_nvme_bdfs)
$rpc_py bdev_nvme_attach_controller -b Nvme0 -t PCIe -a $(echo $bdfs | awk '{ print $1 }') -i $NVMF_FIRST_TARGET_IP
ls_guid=$($rpc_py bdev_lvol_create_lvstore -c 1073741824 Nvme0n1 lvs_0)
get_lvs_free_mb $ls_guid
$rpc_py bdev_lvol_create -l lvs_0 lbd_0 $free_mb
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode2 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 lvs_0/lbd_0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode2
# Test fio_plugin as host with nvme lvol nested backend
ls_nested_guid=$($rpc_py bdev_lvol_create_lvstore --clear-method none lvs_0/lbd_0 lvs_n_0)
get_lvs_free_mb $ls_nested_guid
$rpc_py bdev_lvol_create -l lvs_n_0 lbd_nest_0 $free_mb
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode3 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode3 lvs_n_0/lbd_nest_0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode3 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode3
sync
# Delete lvol_bdev and destroy lvol_store.
$rpc_py bdev_lvol_delete lvs_n_0/lbd_nest_0
$rpc_py bdev_lvol_delete_lvstore -l lvs_n_0
$rpc_py bdev_lvol_delete lvs_0/lbd_0
$rpc_py bdev_lvol_delete_lvstore -l lvs_0
$rpc_py bdev_nvme_detach_controller Nvme0
fi
trap - SIGINT SIGTERM EXIT
rm -f ./local-test-0-verify.state
nvmftestfini
|