From 2c3c1048746a4622d8c89a29670120dc8fab93c4 Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Sun, 7 Apr 2024 20:49:45 +0200 Subject: Adding upstream version 6.1.76. Signed-off-by: Daniel Baumann --- .../arch/x86/skylake/floating-point.json | 73 ++++++++++++++++++++++ 1 file changed, 73 insertions(+) create mode 100644 tools/perf/pmu-events/arch/x86/skylake/floating-point.json (limited to 'tools/perf/pmu-events/arch/x86/skylake/floating-point.json') diff --git a/tools/perf/pmu-events/arch/x86/skylake/floating-point.json b/tools/perf/pmu-events/arch/x86/skylake/floating-point.json new file mode 100644 index 000000000..d6cee5ae4 --- /dev/null +++ b/tools/perf/pmu-events/arch/x86/skylake/floating-point.json @@ -0,0 +1,73 @@ +[ + { + "BriefDescription": "Counts once for most SIMD 128-bit packed computational double precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.", + "Counter": "0,1,2,3", + "CounterHTOff": "0,1,2,3,4,5,6,7", + "EventCode": "0xC7", + "EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_DOUBLE", + "PublicDescription": "Counts once for most SIMD 128-bit packed computational double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 2 computation operations, one for each element. Applies to packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.", + "SampleAfterValue": "2000003", + "UMask": "0x4" + }, + { + "BriefDescription": "Counts once for most SIMD 128-bit packed computational single precision floating-point instruction retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.", + "Counter": "0,1,2,3", + "CounterHTOff": "0,1,2,3,4,5,6,7", + "EventCode": "0xC7", + "EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_SINGLE", + "PublicDescription": "Counts once for most SIMD 128-bit packed computational single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.", + "SampleAfterValue": "2000003", + "UMask": "0x8" + }, + { + "BriefDescription": "Counts once for most SIMD 256-bit packed double computational precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.", + "Counter": "0,1,2,3", + "CounterHTOff": "0,1,2,3,4,5,6,7", + "EventCode": "0xC7", + "EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_DOUBLE", + "PublicDescription": "Counts once for most SIMD 256-bit packed double computational precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.", + "SampleAfterValue": "2000003", + "UMask": "0x10" + }, + { + "BriefDescription": "Counts once for most SIMD 256-bit packed single computational precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.", + "Counter": "0,1,2,3", + "CounterHTOff": "0,1,2,3,4,5,6,7", + "EventCode": "0xC7", + "EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_SINGLE", + "PublicDescription": "Counts once for most SIMD 256-bit packed single computational precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 8 computation operations, one for each element. Applies to packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.", + "SampleAfterValue": "2000003", + "UMask": "0x20" + }, + { + "BriefDescription": "Counts once for most SIMD scalar computational double precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.", + "Counter": "0,1,2,3", + "CounterHTOff": "0,1,2,3,4,5,6,7", + "EventCode": "0xC7", + "EventName": "FP_ARITH_INST_RETIRED.SCALAR_DOUBLE", + "PublicDescription": "Counts once for most SIMD scalar computational double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computational operation. Applies to SIMD scalar double precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.", + "SampleAfterValue": "2000003", + "UMask": "0x1" + }, + { + "BriefDescription": "Counts once for most SIMD scalar computational single precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.", + "Counter": "0,1,2,3", + "CounterHTOff": "0,1,2,3,4,5,6,7", + "EventCode": "0xC7", + "EventName": "FP_ARITH_INST_RETIRED.SCALAR_SINGLE", + "PublicDescription": "Counts once for most SIMD scalar computational single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computational operation. Applies to SIMD scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT RCP FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.", + "SampleAfterValue": "2000003", + "UMask": "0x2" + }, + { + "BriefDescription": "Cycles with any input/output SSE or FP assist", + "Counter": "0,1,2,3", + "CounterHTOff": "0,1,2,3,4,5,6,7", + "CounterMask": "1", + "EventCode": "0xCA", + "EventName": "FP_ASSIST.ANY", + "PublicDescription": "Counts cycles with any input and output SSE or x87 FP assist. If an input and output assist are detected on the same cycle the event increments by 1.", + "SampleAfterValue": "100003", + "UMask": "0x1e" + } +] -- cgit v1.2.3