diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-03-09 13:19:48 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-03-09 13:20:02 +0000 |
commit | 58daab21cd043e1dc37024a7f99b396788372918 (patch) | |
tree | 96771e43bb69f7c1c2b0b4f7374cb74d7866d0cb /collectors/charts.d.plugin/apcupsd/metadata.yaml | |
parent | Releasing debian version 1.43.2-1. (diff) | |
download | netdata-58daab21cd043e1dc37024a7f99b396788372918.tar.xz netdata-58daab21cd043e1dc37024a7f99b396788372918.zip |
Merging upstream version 1.44.3.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'collectors/charts.d.plugin/apcupsd/metadata.yaml')
-rw-r--r-- | collectors/charts.d.plugin/apcupsd/metadata.yaml | 55 |
1 files changed, 55 insertions, 0 deletions
diff --git a/collectors/charts.d.plugin/apcupsd/metadata.yaml b/collectors/charts.d.plugin/apcupsd/metadata.yaml index 07d56d48d..c333dc964 100644 --- a/collectors/charts.d.plugin/apcupsd/metadata.yaml +++ b/collectors/charts.d.plugin/apcupsd/metadata.yaml @@ -124,6 +124,34 @@ modules: link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf metric: apcupsd.load info: number of seconds since the last successful data collection + - name: apcupsd_selftest_warning + link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf + metric: apcupsd.selftest + info: self-test failed due to insufficient battery capacity or due to overload. + - name: apcupsd_status_onbatt + link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS has switched to battery power because the input power has failed + - name: apcupsd_status_overload + link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS is overloaded and cannot supply enough power to the load + - name: apcupsd_status_lowbatt + link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS battery is low and needs to be recharged + - name: apcupsd_status_replacebatt + link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS battery has reached the end of its lifespan and needs to be replaced + - name: apcupsd_status_nobatt + link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS has no battery + - name: apcupsd_status_commlost + link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS communication link is lost metrics: folding: title: Metrics @@ -199,3 +227,30 @@ modules: chart_type: line dimensions: - name: online + - name: apcupsd.selftest + description: UPS Self-Test status + unit: status + chart_type: line + dimensions: + - name: OK + - name: NO + - name: BT + - name: NG + - name: apcupsd.status + description: UPS Status + unit: status + chart_type: line + dimensions: + - name: ONLINE + - name: ONBATT + - name: OVERLOAD + - name: LOWBATT + - name: REPLACEBATT + - name: NOBATT + - name: SLAVE + - name: SLAVEDOWN + - name: COMMLOST + - name: CAL + - name: TRIM + - name: BOOST + - name: SHUTTING_DOWN |