diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2023-08-10 09:18:49 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2023-08-10 09:18:49 +0000 |
commit | dd814a7c1a8de056a79f7238578b09236edd5506 (patch) | |
tree | 429e7eed5a634a4efe9a6877ce66da8e64aa1782 /collectors/charts.d.plugin/nut | |
parent | Adding upstream version 1.41.0. (diff) | |
download | netdata-dd814a7c1a8de056a79f7238578b09236edd5506.tar.xz netdata-dd814a7c1a8de056a79f7238578b09236edd5506.zip |
Adding upstream version 1.42.0.upstream/1.42.0
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'collectors/charts.d.plugin/nut')
-rw-r--r-- | collectors/charts.d.plugin/nut/metadata.yaml | 369 | ||||
-rw-r--r-- | collectors/charts.d.plugin/nut/metrics.csv | 12 |
2 files changed, 218 insertions, 163 deletions
diff --git a/collectors/charts.d.plugin/nut/metadata.yaml b/collectors/charts.d.plugin/nut/metadata.yaml index ce6e57007..ea2e6b2eb 100644 --- a/collectors/charts.d.plugin/nut/metadata.yaml +++ b/collectors/charts.d.plugin/nut/metadata.yaml @@ -1,152 +1,219 @@ -meta: - plugin_name: charts.d.plugin - module_name: nut - monitored_instance: - name: UPS/PDU - link: '' - categories: - - data-collection.ups - icon_filename: 'plug-circle-bolt.svg' - related_resources: - integrations: - list: [] - info_provided_to_referring_integrations: - description: '' - keywords: [] - most_popular: false -overview: - data_collection: - metrics_description: 'Examine UPS/PDU metrics with Netdata for insights into power device performance. Improve your power device performance with comprehensive dashboards and anomaly detection.' - method_description: '' - supported_platforms: - include: [] - exclude: [] - multi-instance: true - additional_permissions: - description: '' - default_behavior: - auto_detection: - description: '' - limits: - description: '' - performance_impact: - description: '' -setup: - prerequisites: - list: [] - configuration: - file: - name: '' - description: '' - options: - description: '' - folding: - title: '' - enabled: true - list: [] - examples: - folding: - enabled: true - title: '' - list: [] -troubleshooting: - problems: - list: [] -alerts: -- name: nut_ups_charge - link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf - metric: nut.charge - info: average UPS charge over the last minute - os: "*" -- name: nut_10min_ups_load - link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf - metric: nut.load - info: average UPS load over the last 10 minutes - os: "*" -- name: nut_last_collected_secs - link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf - metric: nut.load - info: number of seconds since the last successful data collection -metrics: - folding: - title: Metrics - enabled: false - description: "" - availability: [] - scopes: - - name: ups - description: "" - labels: [] +plugin_name: charts.d.plugin +modules: + - meta: + plugin_name: charts.d.plugin + module_name: nut + monitored_instance: + name: Network UPS Tools (NUT) + link: '' + categories: + - data-collection.ups + icon_filename: 'plug-circle-bolt.svg' + related_resources: + integrations: + list: [] + info_provided_to_referring_integrations: + description: '' + keywords: + - nut + - network ups tools + - ups + - pdu + most_popular: false + overview: + data_collection: + metrics_description: 'Examine UPS/PDU metrics with Netdata for insights into power device performance. Improve your power device performance with comprehensive dashboards and anomaly detection.' + method_description: 'This collector uses the `nut` (Network UPS Tools) to query statistics for multiple UPS devices.' + supported_platforms: + include: [] + exclude: [] + multi_instance: true + additional_permissions: + description: '' + default_behavior: + auto_detection: + description: '' + limits: + description: '' + performance_impact: + description: '' + setup: + prerequisites: + list: + - title: "Required software" + description: "Make sure the Network UPS Tools (`nut`) is installed and can detect your UPS devices." + configuration: + file: + name: charts.d/nut.conf + options: + description: | + The config file is sourced by the charts.d plugin. It's a standard bash file. + + The following collapsed table contains all the options that can be configured for the nut collector. + folding: + title: "Config options" + enabled: true + list: + - name: nut_ups + description: A space separated list of UPS names. If empty, the list returned by `upsc -l` will be used. + default_value: "" + required: false + - name: nut_names + description: Each line represents an alias for one UPS. If empty, the FQDN will be used. + default_value: "" + required: false + - name: nut_timeout + description: How long to wait for nut to respond. + default_value: 2 + required: false + - name: nut_clients_chart + description: Set this to 1 to enable another chart showing the number of UPS clients connected to `upsd`. + default_value: 1 + required: false + - name: nut_update_every + description: The data collection frequency. If unset, will inherit the netdata update frequency. + default_value: 2 + required: false + - name: nut_priority + description: The charts priority on the dashboard + default_value: 90000 + required: false + - name: nut_retries + description: The number of retries to do in case of failure before disabling the collector. + default_value: 10 + required: false + examples: + folding: + enabled: true + title: "Config" + list: + - name: Provide names to UPS devices + description: Map aliases to UPS devices + config: | + # a space separated list of UPS names + # if empty, the list returned by 'upsc -l' will be used + #nut_ups= + + # each line represents an alias for one UPS + # if empty, the FQDN will be used + nut_names["XXXXXX"]="UPS-office" + nut_names["YYYYYY"]="UPS-rack" + + # how much time in seconds, to wait for nut to respond + #nut_timeout=2 + + # set this to 1, to enable another chart showing the number + # of UPS clients connected to upsd + #nut_clients_chart=1 + + # the data collection frequency + # if unset, will inherit the netdata update frequency + #nut_update_every=2 + + # the charts priority on the dashboard + #nut_priority=90000 + + # the number of retries to do in case of failure + # before disabling the module + #nut_retries=10 + troubleshooting: + problems: + list: [] + alerts: + - name: nut_ups_charge + link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf + metric: nut.charge + info: average UPS charge over the last minute + os: "*" + - name: nut_10min_ups_load + link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf + metric: nut.load + info: average UPS load over the last 10 minutes + os: "*" + - name: nut_last_collected_secs + link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf + metric: nut.load + info: number of seconds since the last successful data collection metrics: - - name: nut.charge - description: UPS Charge - unit: "percentage" - chart_type: area - dimensions: - - name: charge - - name: nut.runtime - description: UPS Runtime - unit: "seconds" - chart_type: line - dimensions: - - name: runtime - - name: nut.battery.voltage - description: UPS Battery Voltage - unit: "Volts" - chart_type: line - dimensions: - - name: voltage - - name: high - - name: low - - name: nominal - - name: nut.input.voltage - description: UPS Input Voltage - unit: "Volts" - chart_type: line - dimensions: - - name: voltage - - name: fault - - name: nominal - - name: nut.input.current - description: UPS Input Current - unit: "Ampere" - chart_type: line - dimensions: - - name: nominal - - name: nut.input.frequency - description: UPS Input Frequency - unit: "Hz" - chart_type: line - dimensions: - - name: frequency - - name: nominal - - name: nut.output.voltage - description: UPS Output Voltage - unit: "Volts" - chart_type: line - dimensions: - - name: voltage - - name: nut.load - description: UPS Load - unit: "percentage" - chart_type: area - dimensions: - - name: load - - name: nut.load_usage - description: UPS Load Usage - unit: "Watts" - chart_type: area - dimensions: - - name: load_usage - - name: nut.temperature - description: UPS Temperature - unit: "temperature" - chart_type: line - dimensions: - - name: temp - - name: nut.clients - description: UPS Connected Clients - unit: "clients" - chart_type: area - dimensions: - - name: clients + folding: + title: Metrics + enabled: false + description: "" + availability: [] + scopes: + - name: ups + description: "Metrics related to UPS. Each UPS provides its own set of the following metrics." + labels: [] + metrics: + - name: nut.charge + description: UPS Charge + unit: "percentage" + chart_type: area + dimensions: + - name: charge + - name: nut.runtime + description: UPS Runtime + unit: "seconds" + chart_type: line + dimensions: + - name: runtime + - name: nut.battery.voltage + description: UPS Battery Voltage + unit: "Volts" + chart_type: line + dimensions: + - name: voltage + - name: high + - name: low + - name: nominal + - name: nut.input.voltage + description: UPS Input Voltage + unit: "Volts" + chart_type: line + dimensions: + - name: voltage + - name: fault + - name: nominal + - name: nut.input.current + description: UPS Input Current + unit: "Ampere" + chart_type: line + dimensions: + - name: nominal + - name: nut.input.frequency + description: UPS Input Frequency + unit: "Hz" + chart_type: line + dimensions: + - name: frequency + - name: nominal + - name: nut.output.voltage + description: UPS Output Voltage + unit: "Volts" + chart_type: line + dimensions: + - name: voltage + - name: nut.load + description: UPS Load + unit: "percentage" + chart_type: area + dimensions: + - name: load + - name: nut.load_usage + description: UPS Load Usage + unit: "Watts" + chart_type: area + dimensions: + - name: load_usage + - name: nut.temperature + description: UPS Temperature + unit: "temperature" + chart_type: line + dimensions: + - name: temp + - name: nut.clients + description: UPS Connected Clients + unit: "clients" + chart_type: area + dimensions: + - name: clients diff --git a/collectors/charts.d.plugin/nut/metrics.csv b/collectors/charts.d.plugin/nut/metrics.csv deleted file mode 100644 index 2abd57251..000000000 --- a/collectors/charts.d.plugin/nut/metrics.csv +++ /dev/null @@ -1,12 +0,0 @@ -metric,scope,dimensions,unit,description,chart_type,labels,plugin,module -nut.charge,ups,charge,percentage,"UPS Charge",area,,charts.d.plugin,nut -nut.runtime,ups,runtime,seconds,"UPS Runtime",line,,charts.d.plugin,nut -nut.battery.voltage,ups,"voltage, high, low, nominal",Volts,"UPS Battery Voltage",line,,charts.d.plugin,nut -nut.input.voltage,ups,"voltage, fault, nominal",Volts,"UPS Input Voltage",line,,charts.d.plugin,nut -nut.input.current,ups,nominal,Ampere,"UPS Input Current",line,,charts.d.plugin,nut -nut.input.frequency,ups,"frequency, nominal",Hz,"UPS Input Frequency",line,,charts.d.plugin,nut -nut.output.voltage,ups,voltage,Volts,"UPS Output Voltage",line,,charts.d.plugin,nut -nut.load,ups,load,percentage,"UPS Load",area,,charts.d.plugin,nut -nut.load_usage,ups,load_usage,Watts,"UPS Load Usage",area,,charts.d.plugin,nut -nut.temperature,ups,temp,temperature,"UPS Temperature",line,,charts.d.plugin,nut -nut.clients,ups,clients,clients,"UPS Connected Clients",area,,charts.d.plugin,nut
\ No newline at end of file |