diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2021-02-07 11:49:00 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2021-02-07 12:42:05 +0000 |
commit | 2e85f9325a797977eea9dfea0a925775ddd211d9 (patch) | |
tree | 452c7f30d62fca5755f659b99e4e53c7b03afc21 /daemon/config/README.md | |
parent | Releasing debian version 1.19.0-4. (diff) | |
download | netdata-2e85f9325a797977eea9dfea0a925775ddd211d9.tar.xz netdata-2e85f9325a797977eea9dfea0a925775ddd211d9.zip |
Merging upstream version 1.29.0.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'daemon/config/README.md')
-rw-r--r-- | daemon/config/README.md | 153 |
1 files changed, 117 insertions, 36 deletions
diff --git a/daemon/config/README.md b/daemon/config/README.md index 72d961b1e..a1e2b04b5 100644 --- a/daemon/config/README.md +++ b/daemon/config/README.md @@ -1,19 +1,26 @@ +<!-- +title: "Daemon configuration" +description: "The Netdata Agent's daemon is installed preconfigured to collect thousands of metrics every second, but is highly configurable for real-world workloads." +custom_edit_url: https://github.com/netdata/netdata/edit/master/daemon/config/README.md +--> + # Daemon configuration <details markdown="1"><summary>The daemon configuration file is read from `/etc/netdata/netdata.conf`.</summary> Depending on your installation method, Netdata will have been installed either directly under `/`, or under `/opt/netdata`. The paths mentioned here and in the documentation in general assume that your installation is under `/`. If it is not, you will find the exact same paths under `/opt/netdata` as well. (i.e. `/etc/netdata` will be `/opt/netdata/etc/netdata`).</details> -This config file **is not needed by default**. Netdata works fine out of the box without it. But it does allow you to adapt the general behavior of Netdata, in great detail. You can find all these settings, with their default values, by accessing the URL `https://netdata.server.hostname:19999/netdata.conf`. For example check the configuration file of [netdata.firehol.org](http://netdata.firehol.org/netdata.conf). HTTP access to this file is limited by default to private IPs, via the [web server access lists](../../web/server/#access-lists). +This config file **is not needed by default**. Netdata works fine out of the box without it. But it does allow you to adapt the general behavior of Netdata, in great detail. You can find all these settings, with their default values, by accessing the URL `https://netdata.server.hostname:19999/netdata.conf`. For example check the configuration file of [netdata.firehol.org](http://netdata.firehol.org/netdata.conf). HTTP access to this file is limited by default to private IPs, via the [web server access lists](/web/server/README.md#access-lists). `netdata.conf` has sections stated with `[section]`. You will see the following sections: -1. `[global]` to [configure](#global-section-options) the [Netdata daemon](../). -2. `[web]` to [configure the web server](../../web/server). -3. `[plugins]` to [configure](#plugins-section-options) which [collectors](../../collectors) to use and PATH settings. -4. `[health]` to [configure](#health-section-options) general settings for [health monitoring](../../health) -5. `[registry]` for the [Netdata registry](../../registry). -6. `[backend]` to set up [streaming and replication](../../streaming) options. -7. `[statsd]` for the general settings of the [stats.d.plugin](../../collectors/statsd.plugin). +1. `[global]` to [configure](#global-section-options) the [Netdata daemon](/daemon/README.md). +2. `[web]` to [configure the web server](/web/server/README.md). +3. `[plugins]` to [configure](#plugins-section-options) which [collectors](/collectors/README.md) to use and PATH + settings. +4. `[health]` to [configure](#health-section-options) general settings for [health monitoring](/health/README.md) +5. `[registry]` for the [Netdata registry](/registry/README.md). +6. `[backend]` to set up [streaming and replication](/streaming/README.md) options. +7. `[statsd]` for the general settings of the [stats.d.plugin](/collectors/statsd.plugin/README.md). 8. `[plugin:NAME]` sections for each collector plugin, under the comment [Per plugin configuration](#per-plugin-configuration). 9. `[CHART_NAME]` sections for each chart defined, under the comment [Per chart configuration](#per-chart-configuration). @@ -41,43 +48,47 @@ Please note that your data history will be lost if you have modified `history` p | setting|default|info||| |:-----:|:-----:|:---|---|---| -| process scheduling policy|`keep`|See [Netdata process scheduling policy](../#netdata-process-scheduling-policy)||| +| process scheduling policy|`keep`|See [Netdata process scheduling policy](/daemon/README.md#netdata-process-scheduling-policy)||| | OOM score|`1000`|See [OOM score](../#oom-score)||| -| glibc malloc arena max for plugins|`1`|See [Virtual memory](../#virtual-memory).||| -| glibc malloc arena max for Netdata|`1`|See [Virtual memory](../#virtual-memory).||| +| glibc malloc arena max for plugins|`1`|See [Virtual memory](/daemon/README.md#virtual-memory).||| +| glibc malloc arena max for Netdata|`1`|See [Virtual memory](/daemon/README.md#virtual-memory).||| | hostname|auto-detected|The hostname of the computer running Netdata.||| -| history|`3996`|The number of entries the `netdata` daemon will by default keep in memory for each chart dimension. This setting can also be configured per chart. Check [Memory Requirements](../../database/#database) for more information.||| -| update every|`1`|The frequency in seconds, for data collection. For more information see [Performance](../../docs/Performance.md#performance).||| +| history|`3996`| Used with `memory mode = save/map/ram/alloc`, not the default `memory mode = dbengine`. This number reflects the number of entries the `netdata` daemon will by default keep in memory for each chart dimension. This setting can also be configured per chart. Check [Memory Requirements](/database/README.md) for more information. ||| +| update every|`1`|The frequency in seconds, for data collection. For more information see the [performance guide](/docs/guides/configure/performance.md).||| | config directory|`/etc/netdata`|The directory configuration files are kept.||| | stock config directory|`/usr/lib/netdata/conf.d`|||| -| log directory|`/var/log/netdata`|The directory in which the [log files](../#log-files) are kept.||| +| log directory|`/var/log/netdata`|The directory in which the [log files](/daemon/README.md#log-files) are kept.||| | web files directory|`/usr/share/netdata/web`|The directory the web static files are kept.||| | cache directory|`/var/cache/netdata`|The directory the memory database will be stored if and when Netdata exits. Netdata will re-read the database when it will start again, to continue from the same point.||| | lib directory|`/var/lib/netdata`|Contains the alarm log and the Netdata instance guid.||| | home directory|`/var/cache/netdata`|Contains the db files for the collected metrics||| | plugins directory|`"/usr/libexec/netdata/plugins.d" "/etc/netdata/custom-plugins.d"`|The directory plugin programs are kept. This setting supports multiple directories, space separated. If any directory path contains spaces, enclose it in single or double quotes.||| -| memory mode|`save`|When set to `save` Netdata will save its round robin database on exit and load it on startup. When set to `map` the cache files will be updated in real time (check `man mmap` - do not set this on systems with heavy load or slow disks - the disks will continuously sync the in-memory database of Netdata). When set to `dbengine` it behaves similarly to `map` but with much better disk and memory efficiency, however, with higher overhead. When set to `ram` the round robin database will be temporary and it will be lost when Netdata exits. `none` disables the database at this host. This also disables health monitoring (there cannot be health monitoring without a database). host access prefix||This is used in docker environments where /proc, /sys, etc have to be accessed via another path. You may also have to set SYS_PTRACE capability on the docker for this work. Check [issue 43](https://github.com/netdata/netdata/issues/43).| -| memory deduplication (ksm)|`yes`|When set to `yes`, Netdata will offer its in-memory round robin database to kernel same page merging (KSM) for deduplication. For more information check [Memory Deduplication - Kernel Same Page Merging - KSM](../../database/#ksm)||| +| memory mode | `dbengine` | `dbengine`: The default for long-term metrics storage with efficient RAM and disk usage. Can be extended with `page cache size` and `dbengine disk space`. <br />`save`: Netdata will save its round robin database on exit and load it on startup. <br />`map`: Cache files will be updated in real-time. Not ideal for systems with high load or slow disks (check `man mmap`). <br />`ram`: The round-robin database will be temporary and it will be lost when Netdata exits. <br />`none`: Disables the database at this host, and disables health monitoring entirely, as that requires a database of metrics. | +| page cache size | 32 | Determines the amount of RAM in MiB that is dedicated to caching Netdata metric values. ||| +| dbengine disk space | 256 | Determines the amount of disk space in MiB that is dedicated to storing Netdata metric values and all related metadata describing them. ||| +| dbengine multihost disk space | 256 | Same functionality as `dbengine disk space`, but includes support for storing metrics streamed to a parent node by its children. Can be used in single-node environments as well. ||| +| host access prefix||This is used in docker environments where /proc, /sys, etc have to be accessed via another path. You may also have to set SYS_PTRACE capability on the docker for this work. Check [issue 43](https://github.com/netdata/netdata/issues/43).| +| memory deduplication (ksm)|`yes`|When set to `yes`, Netdata will offer its in-memory round robin database to kernel same page merging (KSM) for deduplication. For more information check [Memory Deduplication - Kernel Same Page Merging - KSM](/database/README.md#ksm)||| | TZ environment variable|`:/etc/localtime`|Where to find the timezone||| | timezone|auto-detected|The timezone retrieved from the environment variable||| -| debug flags|`0x0000000000000000`|Bitmap of debug options to enable. For more information check [Tracing Options](../#debugging).||| -| debug log|`/var/log/netdata/debug.log`|The filename to save debug information. This file will not be created if debugging is not enabled. You can also set it to `syslog` to send the debug messages to syslog, or `none` to disable this log. For more information check [Tracing Options](../#debugging).||| +| debug flags|`0x0000000000000000`|Bitmap of debug options to enable. For more information check [Tracing Options](/daemon/README.md#debugging).||| +| debug log|`/var/log/netdata/debug.log`|The filename to save debug information. This file will not be created if debugging is not enabled. You can also set it to `syslog` to send the debug messages to syslog, or `none` to disable this log. For more information check [Tracing Options](/daemon/README.md#debugging).||| | error log|`/var/log/netdata/error.log`|The filename to save error messages for Netdata daemon and all plugins (`stderr` is sent here for all Netdata programs, including the plugins). You can also set it to `syslog` to send the errors to syslog, or `none` to disable this log.||| | access log|`/var/log/netdata/access.log`|The filename to save the log of web clients accessing Netdata charts. You can also set it to `syslog` to send the access log to syslog, or `none` to disable this log.||| -| errors flood protection period|`1200`|UNUSED - Length of period (in sec) during which the number of errors should not exceed the `errors to trigger flood protection`.||| -| errors to trigger flood protection|`200`|UNUSED - Number of errors written to the log in `errors flood protection period` sec before flood protection is activated.||| +| errors flood protection period|`1200`|Length of period (in sec) during which the number of errors should not exceed the `errors to trigger flood protection`.||| +| errors to trigger flood protection|`200`|Number of errors written to the log in `errors flood protection period` sec before flood protection is activated.||| | run as user|`netdata`|The user Netdata will run as.||| | pthread stack size|auto-detected|||| -| cleanup obsolete charts after seconds|`3600`|See [monitoring ephemeral containers](../../collectors/cgroups.plugin/#monitoring-ephemeral-containers), also sets the timeout for cleaning up obsolete dimensions||| +| cleanup obsolete charts after seconds|`3600`|See [monitoring ephemeral containers](/collectors/cgroups.plugin/README.md#monitoring-ephemeral-containers), also sets the timeout for cleaning up obsolete dimensions||| | gap when lost iterations above|`1`|||| -| cleanup orphan hosts after seconds|`3600`|How long to wait until automatically removing from the DB a remote Netdata host (slave) that is no longer sending data.||| -| delete obsolete charts files|`yes`|See [monitoring ephemeral containers](../../collectors/cgroups.plugin/#monitoring-ephemeral-containers), also affects the deletion of files for obsolete dimensions||| +| cleanup orphan hosts after seconds|`3600`|How long to wait until automatically removing from the DB a remote Netdata host (child) that is no longer sending data.||| +| delete obsolete charts files|`yes`|See [monitoring ephemeral containers](/collectors/cgroups.plugin/README.md#monitoring-ephemeral-containers), also affects the deletion of files for obsolete dimensions||| | delete orphan hosts files|`yes`|Set to `no` to disable non-responsive host removal.||| | enable zero metrics|`no`|Set to `yes` to show charts when all their metrics are zero.||| ### [web] section options -Refer to the [web server documentation](../../web/server) +Refer to the [web server documentation](/web/server/README.md) ### [plugins] section options @@ -89,7 +100,7 @@ Additionally, there will be the following options: |:-----:|:-----:|:---| | PATH environment variable|`auto-detected`|| | PYTHONPATH environment variable||Used to set a custom python path| -| enable running new plugins|`yes`|When set to `yes`, Netdata will enable detected plugins, even if they are not configured explicitly. Setting this to `no` will only enable plugins explicitly configirued in this file with a `yes`| +| enable running new plugins|`yes`|When set to `yes`, Netdata will enable detected plugins, even if they are not configured explicitly. Setting this to `no` will only enable plugins explicitly configured in this file with a `yes`| | check for new plugins every|60|The time in seconds to check for new plugins in the plugins directory. This allows having other applications dynamically creating plugins for Netdata.| | checks|`no`|This is a debugging plugin for the internal latency| @@ -97,9 +108,10 @@ Additionally, there will be the following options: This section controls the general behavior of the health monitoring capabilities of Netdata. -Specific alarms are configured in per-collector config files under the `health.d` directory. For more info, see [health monitoring](../../health/#health-monitoring). +Specific alarms are configured in per-collector config files under the `health.d` directory. For more info, see [health +monitoring](/health/README.md). -[Alarm notifications](../../health/notifications/#netdata-alarm-notifications) are configured in `health_alarm_notify.conf`. +[Alarm notifications](/health/notifications/README.md) are configured in `health_alarm_notify.conf`. | setting|default|info| |:-----:|:-----:|:---| @@ -114,35 +126,104 @@ Specific alarms are configured in per-collector config files under the `health.d ### [registry] section options -To understand what this section is and how it should be configured, please refer to the [registry documentation](../../registry). +To understand what this section is and how it should be configured, please refer to the [registry documentation](/registry/README.md). ### [backend] -Refer to the [streaming and replication](../../streaming) documentation. +Refer to the [streaming and replication](/streaming/README.md) documentation. -### Per plugin configuration +## Per-plugin configuration The configuration options for plugins appear in sections following the pattern `[plugin:NAME]`. -#### Internal plugins +### Internal plugins -Most internal plugins will provide additional options. Check [Internal Plugins](../../collectors/) for more information. +Most internal plugins will provide additional options. Check [Internal Plugins](/collectors/README.md) for more +information. Please note, that by default Netdata will enable monitoring metrics for disks, memory, and network only when they are not zero. If they are constantly zero they are ignored. Metrics that will start having values, after Netdata is started, will be detected and charts will be automatically added to the dashboard (a refresh of the dashboard is needed for them to appear though). Use `yes` instead of `auto` in plugin configuration sections to enable these charts permanently. You can also set the `enable zero metrics` option to `yes` in the `[global]` section which enables charts with zero metrics for all internal Netdata plugins. -#### External plugins +### External plugins External plugins will have only 2 options at `netdata.conf`: | setting | default | info | | :-----:|:-----:|:---| -| update every | the value of `[global].update every` setting|The frequency in seconds the plugin should collect values. For more information check [Performance](../../docs/Performance.md#performance).| +| update every | the value of `[global].update every` setting|The frequency in seconds the plugin should collect values. For more information check the [performance guide](/docs/guides/configure/performance.md).| | command options | _empty_ | Additional command line options to pass to the plugin.| External plugins that need additional configuration may support a dedicated file in `/etc/netdata`. Check their documentation. -### Per chart configuration +## Per-chart configuration + +In this area of `netdata.conf` you can find configuration options for individual charts. They appear in sections +following the pattern `[NAME]`. + +Using the settings and values under these sections, you can control all aspects of a specific chart. You can change its +title, make it appear higher in Netdata's [menu](/web/gui/README.md#metrics-menus), tweak its dimensions, and much more. + +To find the name of a given chart, and thus the name of its section in `netdata.conf`, look at the top-left corner of a +chart: + +![Finding the unique ID of a +chart](https://user-images.githubusercontent.com/1153921/67443082-43b16e80-f5b8-11e9-8d33-d6ee052c6678.png) + +Every per-chart configuration section has several common settings, which are listed in the table just below. Beneath +that is information about lines that begin with `dim`, which affect a chart's dimensions. + +| Setting | Function | +| :---------------- | :-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | +| `history` | Override the `history` setting in the [[global] options](#global-section-options) for this particular chart. Should be less than or equal to the global `history` setting. | +| `enabled` | A boolean (`yes` or `no`) that explicitly enables or disables the chart in question. | +| `cache directory` | The directory where cache files for this plugin, if needed, are stored. | +| `chart type` | Defines what type of chart to display. It can be `line`, `area`, or `stacked`. If empty or missing, `line` will be used. | +| `type` | Uniquely identify which [metrics menu](/web/gui/README.md#metrics-menus) on the Netdata dashboard this chart should appear under. Some examples include `system` (**System**), `disk` (**Disks**), `net` (**Network Interfaces**), and `netdata` (**Netdata Monitoring**). | +| `family` | Change the chart's [family](/web/README.md#families) from its default. For example, you could force a disk space chart to collect metrics for family `sdb` instead of family `sda`. | +| `units` | Text for the label of the vertical axis of the chart. This means all dimensions should have the same unit of measurement. | +| `context` | Change the default [context](/web/README.md#contexts) of the chart. Changing this setting will affect what metrics and metrics the chart displays, and which alarms are attached to it. | +| `priority` | Define where the chart should appear on the Netdata dashboard. Lower values equal higher priority, so a priority of `1` will place the chart highest, while a priority of `9999999` would place the chart at the bottom of the Netdata dashboard. | +| `name` | The name of the chart that appears in the top-left corner, after the chart's title. You can also use this name when writing [health entities](/health/REFERENCE.md#health-entity-reference). | +| `title` | The text that appears above the chart in the Netdata dashboard. | + +### Dimension settings + +You may notice some settings that begin with `dim` beneath the ones defined in the table above. These settings determine +which dimensions appear on the given chart and how Netdata calculates them. + +Each dimension setting has the following structure: `dim [DIMENSION ID] [OPTION] = [VALUE]`. The available options are `name`, `algorithm`, `multiplier`, and `divisor`. + +| Setting | Function | +| :----------- | :------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | +| `name` | The name of the dimension as it will appear in the legend of the chart. If left empty, or is missing, Netdata will use the `[DIMENSION ID]` instead. | +| `algorithm` | Can be `absolute`, `incremental`, `percentage-of-absolute-row`, or `percentage-of-incremental-row`. If this setting is empty, invalid, or missing, Netdata will use `absolute`. See the list beneath this table for descriptions of what each algorithm does. | +| `multiplier` | An integer value by which to multiply the collected value. If empty or missing, Netdata will use `1`. This setting is often used with the value `1024` to convert metabytes to kilobytes, kilobytes to bytes, and so on. | +| `divisor` | An integer value by which to divide the collected value. If empty or missing, Netdata will use `1`. This setting is often used with the value `1024` to convert bytes to kilobytes, kilobytes to megabytes, and so on. | + +Here are the options for the `algorithm` setting: + +- `absolute`: The value is drawn as-is (interpolated to second boundary). +- `incremental`: To be used when the value always increases over time, such as the I/O on a disk. Netdata takes the + difference between the current metric and the past metric to calculate a per-second figure. +- `percentage-of-absolute-row`: The % of this value compared to the total of all dimensions. +- `percentage-of-incremental-row`: The % of this value compared to the incremental total of all dimensions. + +For example, the `system.io` chart has the following default settings: + +```conf + # dim in name = in + # dim in algorithm = incremental + # dim in multiplier = 1 + # dim in divisor = 1 + # dim out name = out + # dim out algorithm = incremental + # dim out multiplier = -1 + # dim out divisor = 1 +``` + +These `dim` settings produce two dimensions, `in` and `out`, both of which use the `incremental` algorithm. By +multiplying the value of `out` by -1, Netdata creates the negative values seen in the following area chart: -In this section you will find a separate subsection for each chart shown on the dashboard. You can control all aspects of a specific chart here. You can understand what each option does by reading [how charts are defined](../../collectors/plugins.d/#chart). If you don't know how to find the name of a chart, you can learn about it [here](../../web/README.md#charts-contexts-families). +![The system.io chart on a macOS +laptop](https://user-images.githubusercontent.com/1153921/69286708-2cfb3900-0bb1-11ea-9fcd-dd8fbb2adf11.png) [![analytics](https://www.google-analytics.com/collect?v=1&aip=1&t=pageview&_s=1&ds=github&dr=https%3A%2F%2Fgithub.com%2Fnetdata%2Fnetdata&dl=https%3A%2F%2Fmy-netdata.io%2Fgithub%2Fdaemon%2Fconfig%2FREADME&_u=MAC~&cid=5792dfd7-8dc4-476b-af31-da2fdb9f93d2&tid=UA-64295674-3)](<>) |