summaryrefslogtreecommitdiffstats
path: root/docs/Add-more-charts-to-netdata.md
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2019-04-17 17:57:35 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2019-04-17 17:57:35 +0000
commit3b95e5be69c199a2a195c57aba12d88c242225ac (patch)
tree137b72ffaefe7f34bf21e975ccc9cc9ec0474564 /docs/Add-more-charts-to-netdata.md
parentAdding upstream version 1.13.0. (diff)
downloadnetdata-3b95e5be69c199a2a195c57aba12d88c242225ac.tar.xz
netdata-3b95e5be69c199a2a195c57aba12d88c242225ac.zip
Adding upstream version 1.14.0~rc0.upstream/1.14.0_rc0
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'docs/Add-more-charts-to-netdata.md')
-rw-r--r--docs/Add-more-charts-to-netdata.md18
1 files changed, 14 insertions, 4 deletions
diff --git a/docs/Add-more-charts-to-netdata.md b/docs/Add-more-charts-to-netdata.md
index d8a04c85..b62322f2 100644
--- a/docs/Add-more-charts-to-netdata.md
+++ b/docs/Add-more-charts-to-netdata.md
@@ -16,10 +16,11 @@ To collect non-system metrics, netdata supports a plugin architecture. The follo
- **[Name Servers](#name-servers)** (DNS), like bind, nsd, powerdns, dnsdist
- **[DHCP Servers](#dhcp-servers)**, like ISC DHCP
- **[UPS](#ups)**, such as APC UPS, NUT
-- **[RAID](#raid)**, such as linux software raid (mdadm), MegaRAID
+- **[RAID](#raid)**, such as MegaRAID
- **[Mail Servers](#mail-servers)**, like postfix, exim, dovecot
- **[File Servers](#file-servers)**, like samba, NFS, ftp, sftp, WebDAV
- **[Print Servers](#print-servers)**, like CUPS
+- **[Hypervisors](#hypervisors)**, like XenServer, XCP-ng
- **[System](#system)**, for processes and other system metrics
- **[Sensors](#sensors)**, like temperature, fans speed, voltage, humidity, HDD/SSD S.M.A.R.T attributes
- **[Network](#network)**, such as SNMP devices, `fping`, access points, dns_query_time, nfacct
@@ -66,6 +67,7 @@ To control which plugins netdata run, edit `netdata.conf` and check the `[plugin
# fping = yes
# charts.d = yes
# apps = yes
+ # xenstat = yes
```
The default for all plugins is the option `enable running new plugins`. So, setting this to `no` will disable all the plugins, except the ones specifically enabled.
@@ -268,7 +270,6 @@ nut|BASH<br/>Shell Script|Connects to a nut server (upsd) to collect real-time U
application|language|notes|
:---------:|:------:|:----|
-mdstat|python<br/>v2 or v3|Parses `/proc/mdstat` to get mds health metrics.<br/>&nbsp;<br/>netdata plugin: [python.d.plugin](../collectors/python.d.plugin)<br/>plugin module: [mdstat.chart.py](../collectors/python.d.plugin/mdstat)<br/>configuration file: [python.d/mdstat.conf](../collectors/python.d.plugin/mdstat)|
megacli|python<br/>v2 or v3|Collects adapter, physical drives and battery stats..<br/>&nbsp;<br/>netdata plugin: [python.d.plugin](../collectors/python.d.plugin)<br/>plugin module: [megacli.chart.py](../collectors/python.d.plugin/megacli)<br/>configuration file: [python.d/megacli.conf](../collectors/python.d.plugin/megacli)|
---
@@ -294,11 +295,21 @@ NFS Client|`C`|This is handled entirely by the netdata daemon.<br/>&nbsp;<br/>Co
NFS Server|`C`|This is handled entirely by the netdata daemon.<br/>&nbsp;<br/>Configuration: `netdata.conf`, section `[plugin:proc:/proc/net/rpc/nfsd]`.
samba|python<br/>v2 or v3|Performance metrics of Samba SMB2 file sharing.<br/>&nbsp;<br/>documentation page: [python.d.plugin module samba](../collectors/python.d.plugin/samba)<br/>netdata plugin: [python.d.plugin](../collectors/python.d.plugin)<br/>plugin module: [samba.chart.py](../collectors/python.d.plugin/samba)<br/>configuration file: [python.d/samba.conf](../collectors/python.d.plugin/samba)|
+---
+
### Print Servers
application|language|notes|
:---------:|:------:|:----|
-CUPS|C|Charts metrics of printers, jobs and other cups destinations.<br/>&nbsp;<br/>netdata plugin: cups.plugin
+CUPS|C|Charts metrics of printers, jobs and other cups destinations.<br/>&nbsp;<br/>netdata plugin: [cups.plugin](../collectors/cups.plugin)
+
+---
+
+### Hypervisors
+
+application|language|notes|
+:---------:|:------:|:----|
+xenstat|C|Collects host and domain statistics for XenServer or XCP-ng hypervisors.<br/>&nbsp;<br/>netdata plugin: [xenstat.plugin](../collectors/xenstat.plugin)
---
@@ -318,7 +329,6 @@ mem_apps|BASH<br/>Shell Script|Collects the memory footprint of select applicati
application|language|notes|
:---------:|:------:|:----|
-cpufreq|python<br/>v2 or v3|Collects the current CPU frequency from `/sys/devices`.<br/>&nbsp;<br/>netdata plugin: [python.d.plugin](../collectors/python.d.plugin)<br/>plugin module: [cpufreq.chart.py](../collectors/python.d.plugin/cpufreq)<br/>configuration file: [python.d/cpufreq.conf](../collectors/python.d.plugin/cpufreq)|
cpufreq|BASH<br/>Shell Script|Collects current CPU frequency from `/sys/devices`.<br/><br/>DEPRECATED IN FAVOR OF THE PYTHON ONE. It is still supplied only as an example module to shell scripting plugins.<br/>&nbsp;<br/>netdata plugin: [charts.d.plugin](../collectors/charts.d.plugin#chartsdplugin)<br/>plugin module: [cpufreq.chart.sh](../collectors/charts.d.plugin/cpufreq)<br/>configuration file: [charts.d/cpufreq.conf](../collectors/charts.d.plugin/cpufreq)|
IPMI|C|Collects temperatures, voltages, currents, power, fans and `SEL` events from IPMI using `libipmimonitoring`.<br/>Check [Monitoring IPMI](../collectors/freeipmi.plugin/) for more information<br/>&nbsp;<br/>netdata plugin: [freeipmi.plugin](../collectors/freeipmi.plugin)<br/>configuration file: none required - to enable it, compile/install netdata with `--enable-plugin-freeipmi`|
hddtemp|python<br/>v2 or v3|Connects to multiple hddtemp servers (local or remote) to collect real-time performance metrics.<br/>&nbsp;<br/>netdata plugin: [python.d.plugin](../collectors/python.d.plugin)<br/>plugin module: [hddtemp.chart.py](../collectors/python.d.plugin/hddtemp)<br/>configuration file: [python.d/hddtemp.conf](../collectors/python.d.plugin/hddtemp)|