summaryrefslogtreecommitdiffstats
path: root/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh
diff options
context:
space:
mode:
Diffstat (limited to 'collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh')
-rw-r--r--collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh305
1 files changed, 0 insertions, 305 deletions
diff --git a/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh b/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh
deleted file mode 100644
index da9cd19c3..000000000
--- a/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh
+++ /dev/null
@@ -1,305 +0,0 @@
-# shellcheck shell=bash
-# no need for shebang - this file is loaded from charts.d.plugin
-# SPDX-License-Identifier: GPL-3.0-or-later
-
-# netdata
-# real-time performance and health monitoring, done right!
-# (C) 2016 Costa Tsaousis <costa@tsaousis.gr>
-#
-
-apcupsd_ip=
-apcupsd_port=
-
-declare -A apcupsd_sources=(
- ["local"]="127.0.0.1:3551"
-)
-
-# how frequently to collect UPS data
-apcupsd_update_every=10
-
-apcupsd_timeout=3
-
-# the priority of apcupsd related to other charts
-apcupsd_priority=90000
-
-apcupsd_get() {
- run -t $apcupsd_timeout apcaccess status "$1"
-}
-
-is_ups_alive() {
- local status
- status="$(apcupsd_get "$1" | sed -e 's/STATUS.*: //' -e 't' -e 'd')"
- case "$status" in
- "" | "COMMLOST" | "SHUTTING DOWN") return 1 ;;
- *) return 0 ;;
- esac
-}
-
-apcupsd_check() {
-
- # this should return:
- # - 0 to enable the chart
- # - 1 to disable the chart
-
- require_cmd apcaccess || return 1
-
- # backwards compatibility
- if [ "${apcupsd_ip}:${apcupsd_port}" != ":" ]; then
- apcupsd_sources["local"]="${apcupsd_ip}:${apcupsd_port}"
- fi
-
- local host working=0 failed=0
- for host in "${!apcupsd_sources[@]}"; do
- apcupsd_get "${apcupsd_sources[${host}]}" >/dev/null
- # shellcheck disable=2181
- if [ $? -ne 0 ]; then
- error "cannot get information for apcupsd server ${host} on ${apcupsd_sources[${host}]}."
- failed=$((failed + 1))
- else
- if ! is_ups_alive ${apcupsd_sources[${host}]}; then
- error "APC UPS ${host} on ${apcupsd_sources[${host}]} is not online."
- failed=$((failed + 1))
- else
- working=$((working + 1))
- fi
- fi
- done
-
- if [ ${working} -eq 0 ]; then
- error "No APC UPSes found available."
- return 1
- fi
-
- return 0
-}
-
-apcupsd_create() {
- local host
- for host in "${!apcupsd_sources[@]}"; do
- # create the charts
- cat <<EOF
-CHART apcupsd_${host}.charge '' "UPS Charge" "percentage" ups apcupsd.charge area $((apcupsd_priority + 2)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION battery_charge charge absolute 1 100
-
-CHART apcupsd_${host}.battery_voltage '' "UPS Battery Voltage" "Volts" ups apcupsd.battery.voltage line $((apcupsd_priority + 4)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION battery_voltage voltage absolute 1 100
-DIMENSION battery_voltage_nominal nominal absolute 1 100
-
-CHART apcupsd_${host}.input_voltage '' "UPS Input Voltage" "Volts" input apcupsd.input.voltage line $((apcupsd_priority + 5)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION input_voltage voltage absolute 1 100
-DIMENSION input_voltage_min min absolute 1 100
-DIMENSION input_voltage_max max absolute 1 100
-
-CHART apcupsd_${host}.input_frequency '' "UPS Input Frequency" "Hz" input apcupsd.input.frequency line $((apcupsd_priority + 6)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION input_frequency frequency absolute 1 100
-
-CHART apcupsd_${host}.output_voltage '' "UPS Output Voltage" "Volts" output apcupsd.output.voltage line $((apcupsd_priority + 7)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION output_voltage voltage absolute 1 100
-DIMENSION output_voltage_nominal nominal absolute 1 100
-
-CHART apcupsd_${host}.load '' "UPS Load" "percentage" ups apcupsd.load area $((apcupsd_priority)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION load load absolute 1 100
-
-CHART apcupsd_${host}.load_usage '' "UPS Load Usage" "Watts" ups apcupsd.load_usage area $((apcupsd_priority + 1)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION load_usage load absolute 1 100
-
-CHART apcupsd_${host}.temp '' "UPS Temperature" "Celsius" ups apcupsd.temperature line $((apcupsd_priority + 8)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION temp temp absolute 1 100
-
-CHART apcupsd_${host}.time '' "UPS Time Remaining" "Minutes" ups apcupsd.time area $((apcupsd_priority + 3)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION time time absolute 1 100
-
-CHART apcupsd_${host}.online '' "UPS ONLINE flag" "boolean" ups apcupsd.online line $((apcupsd_priority + 9)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION online online absolute 1 1
-
-CHART apcupsd_${host}.selftest '' "UPS Self-Test status" "status" ups apcupsd.selftest line $((apcupsd_priority + 10)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION selftest_OK 'OK' absolute 1 1
-DIMENSION selftest_NO 'NO' absolute 1 1
-DIMENSION selftest_BT 'BT' absolute 1 1
-DIMENSION selftest_NG 'NG' absolute 1 1
-
-CHART apcupsd_${host}.status '' "UPS Status" "status" ups apcupsd.status line $((apcupsd_priority + 11)) $apcupsd_update_every '' '' 'apcupsd'
-DIMENSION status_ONLINE 'ONLINE' absolute 1 1
-DIMENSION status_ONBATT 'ONBATT' absolute 1 1
-DIMENSION status_OVERLOAD 'OVERLOAD' absolute 1 1
-DIMENSION status_LOWBATT 'LOWBATT' absolute 1 1
-DIMENSION status_REPLACEBATT 'REPLACEBATT' absolute 1 1
-DIMENSION status_NOBATT 'NOBATT' absolute 1 1
-DIMENSION status_SLAVE 'SLAVE' absolute 1 1
-DIMENSION status_SLAVEDOWN 'SLAVEDOWN' absolute 1 1
-DIMENSION status_COMMLOST 'COMMLOST' absolute 1 1
-DIMENSION status_CAL 'CAL' absolute 1 1
-DIMENSION status_TRIM 'TRIM' absolute 1 1
-DIMENSION status_BOOST 'BOOST' absolute 1 1
-DIMENSION status_SHUTTING_DOWN 'SHUTTING_DOWN' absolute 1 1
-
-EOF
- done
- return 0
-}
-
-apcupsd_update() {
- # the first argument to this function is the microseconds since last update
- # pass this parameter to the BEGIN statement (see below).
-
- # do all the work to collect / calculate the values
- # for each dimension
- # remember: KEEP IT SIMPLE AND SHORT
-
- local host working=0 failed=0
- for host in "${!apcupsd_sources[@]}"; do
- apcupsd_get "${apcupsd_sources[${host}]}" | awk "
-
-BEGIN {
- battery_charge = 0;
- battery_voltage = 0;
- battery_voltage_nominal = 0;
- input_voltage = 0;
- input_voltage_min = 0;
- input_voltage_max = 0;
- input_frequency = 0;
- output_voltage = 0;
- output_voltage_nominal = 0;
- load = 0;
- temp = 0;
- time = 0;
- nompower = 0;
- load_usage = 0;
- selftest_OK = 0;
- selftest_NO = 0;
- selftest_BT = 0;
- selftest_NG = 0;
- status_ONLINE = 0;
- status_CAL = 0;
- status_TRIM = 0;
- status_BOOST = 0;
- status_ONBATT = 0;
- status_OVERLOAD = 0;
- status_LOWBATT = 0;
- status_REPLACEBATT = 0;
- status_NOBATT = 0;
- status_SLAVE = 0;
- status_SLAVEDOWN = 0;
- status_COMMLOST = 0;
- status_SHUTTING_DOWN = 0;
-
-}
-/^BCHARGE.*/ { battery_charge = \$3 * 100 };
-/^BATTV.*/ { battery_voltage = \$3 * 100 };
-/^NOMBATTV.*/ { battery_voltage_nominal = \$3 * 100 };
-/^LINEV.*/ { input_voltage = \$3 * 100 };
-/^MINLINEV.*/ { input_voltage_min = \$3 * 100 };
-/^MAXLINEV.*/ { input_voltage_max = \$3 * 100 };
-/^LINEFREQ.*/ { input_frequency = \$3 * 100 };
-/^OUTPUTV.*/ { output_voltage = \$3 * 100 };
-/^NOMOUTV.*/ { output_voltage_nominal = \$3 * 100 };
-/^LOADPCT.*/ { load = \$3 * 100 };
-/^ITEMP.*/ { temp = \$3 * 100 };
-/^NOMPOWER.*/ { nompower = \$3 };
-/^TIMELEFT.*/ { time = \$3 * 100 };
-/^STATUS.*/ { online=(\$3 != \"COMMLOST\" && !(\$3 == \"SHUTTING\" && \$4 == \"DOWN\"))?1:0; };
-/^SELFTEST.*/ { selftest_OK = (\$3 == \"OK\") ? 1 : 0;
- selftest_NO = (\$3 == \"NO\") ? 1 : 0;
- selftest_BT = (\$3 == \"BT\") ? 1 : 0;
- selftest_NG = (\$3 == \"NG\") ? 1 : 0;
- };
-/^STATUS.*/ { status_ONLINE = (\$3 == \"ONLINE\") ? 1 : 0;
- status_CAL = (\$3 == \"CAL\") ? 1 : 0;
- status_TRIM = (\$3 == \"TRIM\") ? 1 : 0;
- status_BOOST = (\$3 == \"BOOST\") ? 1 : 0;
- status_ONBATT = (\$3 == \"ONBATT\") ? 1 : 0;
- status_OVERLOAD = (\$3 == \"OVERLOAD\") ? 1 : 0;
- status_LOWBATT = (\$3 == \"LOWBATT\") ? 1 : 0;
- status_REPLACEBATT = (\$3 == \"REPLACEBATT\") ? 1 : 0;
- status_NOBATT = (\$3 == \"NOBATT\") ? 1 : 0;
- status_SLAVE = (\$3 == \"SLAVE\") ? 1 : 0;
- status_SLAVEDOWN = (\$3 == \"SLAVEDOWN\") ? 1 : 0;
- status_COMMLOST = (\$3 == \"COMMLOST\") ? 1 : 0;
- status_SHUTTING_DOWN = (\$3 == \"SHUTTING\" && \$4 == \"DOWN\") ? 1 : 0;
- };
-
-END {
- { load_usage = nompower * load / 100 };
-
- print \"BEGIN apcupsd_${host}.online $1\";
- print \"SET online = \" online;
- print \"END\"
-
- if (online == 1) {
- print \"BEGIN apcupsd_${host}.charge $1\";
- print \"SET battery_charge = \" battery_charge;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.battery_voltage $1\";
- print \"SET battery_voltage = \" battery_voltage;
- print \"SET battery_voltage_nominal = \" battery_voltage_nominal;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.input_voltage $1\";
- print \"SET input_voltage = \" input_voltage;
- print \"SET input_voltage_min = \" input_voltage_min;
- print \"SET input_voltage_max = \" input_voltage_max;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.input_frequency $1\";
- print \"SET input_frequency = \" input_frequency;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.output_voltage $1\";
- print \"SET output_voltage = \" output_voltage;
- print \"SET output_voltage_nominal = \" output_voltage_nominal;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.load $1\";
- print \"SET load = \" load;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.load_usage $1\";
- print \"SET load_usage = \" load_usage;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.temp $1\";
- print \"SET temp = \" temp;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.time $1\";
- print \"SET time = \" time;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.selftest $1\";
- print \"SET selftest_OK = \" selftest_OK;
- print \"SET selftest_NO = \" selftest_NO;
- print \"SET selftest_BT = \" selftest_BT;
- print \"SET selftest_NG = \" selftest_NG;
- print \"END\"
-
- print \"BEGIN apcupsd_${host}.status $1\";
- print \"SET status_ONLINE = \" status_ONLINE;
- print \"SET status_ONBATT = \" status_ONBATT;
- print \"SET status_OVERLOAD = \" status_OVERLOAD;
- print \"SET status_LOWBATT = \" status_LOWBATT;
- print \"SET status_REPLACEBATT = \" status_REPLACEBATT;
- print \"SET status_NOBATT = \" status_NOBATT;
- print \"SET status_SLAVE = \" status_SLAVE;
- print \"SET status_SLAVEDOWN = \" status_SLAVEDOWN;
- print \"SET status_COMMLOST = \" status_COMMLOST;
- print \"SET status_CAL = \" status_CAL;
- print \"SET status_TRIM = \" status_TRIM;
- print \"SET status_BOOST = \" status_BOOST;
- print \"SET status_SHUTTING_DOWN = \" status_SHUTTING_DOWN;
- print \"END\";
- }
-}"
- # shellcheck disable=SC2181
- if [ $? -ne 0 ]; then
- failed=$((failed + 1))
- error "failed to get values for APC UPS ${host} on ${apcupsd_sources[${host}]}" && return 1
- else
- working=$((working + 1))
- fi
- done
-
- [ $working -eq 0 ] && error "failed to get values from all APC UPSes" && return 1
-
- return 0
-}