summaryrefslogtreecommitdiffstats
path: root/collectors/node.d.plugin/fronius/README.md
diff options
context:
space:
mode:
Diffstat (limited to 'collectors/node.d.plugin/fronius/README.md')
-rw-r--r--collectors/node.d.plugin/fronius/README.md120
1 files changed, 120 insertions, 0 deletions
diff --git a/collectors/node.d.plugin/fronius/README.md b/collectors/node.d.plugin/fronius/README.md
new file mode 100644
index 000000000..dd2846990
--- /dev/null
+++ b/collectors/node.d.plugin/fronius/README.md
@@ -0,0 +1,120 @@
+# fronius
+
+This module collects metrics from the configured solar power installation from Fronius Symo.
+
+**Requirements**
+ * Configuration file `fronius.conf` in the node.d netdata config dir (default: `/etc/netdata/node.d/fronius.conf`)
+ * Fronius Symo with network access (http)
+
+It produces per server:
+
+1. **Power**
+ * Current power input from the grid (positive values), output to the grid (negative values), in W
+ * Current power input from the solar panels, in W
+ * Current power stored in the accumulator (if present), in W (in theory, untested)
+
+2. **Consumption**
+ * Local consumption in W
+
+3. **Autonomy**
+ * Relative autonomy in %. 100 % autonomy means that the solar panels are delivering more power than it is needed by local consumption.
+ * Relative self consumption in %. The lower the better
+
+4. **Energy**
+ * The energy produced during the current day, in kWh
+ * The energy produced during the current year, in kWh
+
+5. **Inverter**
+ * The current power output from the connected inverters, in W, one dimension per inverter. At least one is always present.
+
+
+### configuration
+
+Sample:
+
+```json
+{
+ "enable_autodetect": false,
+ "update_every": 5,
+ "servers": [
+ {
+ "name": "Symo",
+ "hostname": "symo.ip.or.dns",
+ "update_every": 5,
+ "api_path": "/solar_api/v1/GetPowerFlowRealtimeData.fcgi"
+ }
+ ]
+}
+```
+
+If no configuration is given, the module will be disabled. Each `update_every` is optional, the default is `5`.
+
+---
+
+[Fronius Symo 8.2](https://www.fronius.com/en/photovoltaics/products/all-products/inverters/fronius-symo/fronius-symo-8-2-3-m)
+
+The plugin has been tested with a single inverter, namely Fronius Symo 8.2-3-M:
+
+- Datalogger version: 240.162630
+- Software version: 3.7.4-6
+- Hardware version: 2.4D
+
+Other products and versions may work, but without any guarantees.
+
+Example netdata configuration for node.d/fronius.conf. Copy this section to fronius.conf and change name/ip.
+The module supports any number of servers. Sometimes there is a lag when collecting every 3 seconds, so 5 should be okay too. You can modify this per server.
+```json
+{
+ "enable_autodetect": false,
+ "update_every": 5,
+ "servers": [
+ {
+ "name": "solar",
+ "hostname": "symo.ip.or.dns",
+ "update_every": 5,
+ "api_path": "/solar_api/v1/GetPowerFlowRealtimeData.fcgi"
+ }
+ ]
+}
+```
+
+The output of /solar_api/v1/GetPowerFlowRealtimeData.fcgi looks like this:
+```json
+{
+ "Head" : {
+ "RequestArguments" : {},
+ "Status" : {
+ "Code" : 0,
+ "Reason" : "",
+ "UserMessage" : ""
+ },
+ "Timestamp" : "2017-07-05T12:35:12+02:00"
+ },
+ "Body" : {
+ "Data" : {
+ "Site" : {
+ "Mode" : "meter",
+ "P_Grid" : -6834.549847,
+ "P_Load" : -1271.450153,
+ "P_Akku" : null,
+ "P_PV" : 8106,
+ "rel_SelfConsumption" : 15.685297,
+ "rel_Autonomy" : 100,
+ "E_Day" : 35020,
+ "E_Year" : 5826076,
+ "E_Total" : 14788870,
+ "Meter_Location" : "grid"
+ },
+ "Inverters" : {
+ "1" : {
+ "DT" : 123,
+ "P" : 8106,
+ "E_Day" : 35020,
+ "E_Year" : 5826076,
+ "E_Total" : 14788870
+ }
+ }
+ }
+ }
+}
+```