+# linux\_power\_supply
+
+This module monitors variosu metrics reported by power supply drivers
+on Linux. This allows tracking and alerting on things like remaining
+battery capacity.
+
+Depending on the uderlying driver, it may provide the following charts
+and metrics:
+
+1. Capacity: The power supply capacity expressed as a percentage.
+ * capacity\_now
+
+2. Charge: The charge for the power supply, expressed as microamphours.
+ * charge\_full\_design
+ * charge\_full
+ * charge\_now
+ * charge\_empty
+ * charge\_empty\_design
+
+3. Energy: The energy for the power supply, expressed as microwatthours.
+ * energy\_full\_design
+ * energy\_full
+ * energy\_now
+ * energy\_empty
+ * energy\_empty\_design
+
+2. Voltage: The voltage for the power supply, expressed as microvolts.
+ * voltage\_max\_design
+ * voltage\_max
+ * voltage\_now
+ * voltage\_min
+ * voltage\_min\_design
+
+### configuration
+
+Sample:
+
+```yaml
+battery:
+ supply: 'BAT0'
+ charts: 'capacity charge energy voltage'
+```
+
+The `supply` key specifies the name of the power supply device to monitor.
+You can use `ls /sys/class/power_supply` to get a list of such devices
+on your system.
+
+The `charts` key is a space separated list of which charts to try
+to display. It defaults to trying to display everything.
+
+### notes
+
+* Most drivers provide at least the first chart. Battery powered ACPI
+compliant systems (like most laptops) provide all but the third, but do
+not provide all of the metrics for each chart.
+
+* Current, energy, and voltages are reported with a _very_ high precision
+by the power\_supply framework. Usually, this is far higher than the
+actual hardware supports reporting, so expect to see changes in these
+charts jump instead of scaling smoothly.
+
+* If `max` or `full` attribute is defined by the driver, but not a
+corresponding `min or `empty` attribute, then netdata will still provide
+the corresponding `min` or `empty`, which will then always read as zero.
+This way, alerts which match on these will still work.
+
+---