diff options
Diffstat (limited to 'health/health.d/apcupsd.conf')
-rw-r--r-- | health/health.d/apcupsd.conf | 75 |
1 files changed, 75 insertions, 0 deletions
diff --git a/health/health.d/apcupsd.conf b/health/health.d/apcupsd.conf index fc8f2cd0f..90a72af19 100644 --- a/health/health.d/apcupsd.conf +++ b/health/health.d/apcupsd.conf @@ -48,3 +48,78 @@ component: UPS device summary: APC UPS last collection info: APC UPS number of seconds since the last successful data collection to: sitemgr + +#Send out a warning when SELFTEST code is BT or NG. Code descriptions can be found at: +#http://www.apcupsd.org/manual/#:~:text=or%20N/A.-,SELFTEST,-The%20results%20of + template: apcupsd_selftest_warning + on: apcupsd.selftest + lookup: max -1s unaligned match-names of BT,NG + units: status + every: 10s + warn: $this == 1 + delay: up 0 down 15m multiplier 1.5 max 1h + info: APC UPS self-test failed due to insufficient battery capacity or due to overload. + to: sitemgr + +#Send out a warning when STATUS code is ONBATT,OVERLOAD,LOWBATT,REPLACEBATT,NOBATT,COMMLOST +#https://man.archlinux.org/man/apcaccess.8.en#:~:text=apcupsd%20was%20started-,STATUS,-%3A%20UPS%20status.%20One + + template: apcupsd_status_onbatt + on: apcupsd.status + lookup: max -1s unaligned match-names of ONBATT + units: status + every: 10s + warn: $this == 1 + delay: up 1m down 15m multiplier 1.5 max 1h + info: APC UPS has switched to battery power because the input power has failed + to: sitemgr + + template: apcupsd_status_overload + on: apcupsd.status + lookup: max -1s unaligned match-names of OVERLOAD + units: status + every: 10s + warn: $this == 1 + delay: up 0 down 15m multiplier 1.5 max 1h + info: APC UPS is overloaded and cannot supply enough power to the load + to: sitemgr + + template: apcupsd_status_lowbatt + on: apcupsd.status + lookup: max -1s unaligned match-names of LOWBATT + units: status + every: 10s + warn: $this == 1 + delay: up 0 down 15m multiplier 1.5 max 1h + info: APC UPS battery is low and needs to be recharged + to: sitemgr + + template: apcupsd_status_replacebatt + on: apcupsd.status + lookup: max -1s unaligned match-names of REPLACEBATT + units: status + every: 10s + warn: $this == 1 + delay: up 0 down 15m multiplier 1.5 max 1h + info: APC UPS battery has reached the end of its lifespan and needs to be replaced + to: sitemgr + + template: apcupsd_status_nobatt + on: apcupsd.status + lookup: max -1s unaligned match-names of NOBATT + units: status + every: 10s + warn: $this == 1 + delay: up 0 down 15m multiplier 1.5 max 1h + info: APC UPS has no battery + to: sitemgr + + template: apcupsd_status_commlost + on: apcupsd.status + lookup: max -1s unaligned match-names of COMMLOST + units: status + every: 10s + warn: $this == 1 + delay: up 0 down 15m multiplier 1.5 max 1h + info: APC UPS communication link is lost + to: sitemgr |