diff options
Diffstat (limited to 'health/health.d/apcupsd.conf')
-rw-r--r-- | health/health.d/apcupsd.conf | 125 |
1 files changed, 0 insertions, 125 deletions
diff --git a/health/health.d/apcupsd.conf b/health/health.d/apcupsd.conf deleted file mode 100644 index 90a72af1..00000000 --- a/health/health.d/apcupsd.conf +++ /dev/null @@ -1,125 +0,0 @@ -# you can disable an alarm notification by setting the 'to' line to: silent - - template: apcupsd_10min_ups_load - on: apcupsd.load - class: Utilization - type: Power Supply -component: UPS - os: * - hosts: * - lookup: average -10m unaligned of percentage - units: % - every: 1m - warn: $this > (($status >= $WARNING) ? (70) : (80)) - delay: down 10m multiplier 1.5 max 1h - summary: APC UPS load - info: APC UPS average load over the last 10 minutes - to: sitemgr - -# Discussion in https://github.com/netdata/netdata/pull/3928: -# Fire the alarm as soon as it's going on battery (99% charge) and clear only when full. - template: apcupsd_ups_charge - on: apcupsd.charge - class: Errors - type: Power Supply -component: UPS - os: * - hosts: * - lookup: average -60s unaligned of charge - units: % - every: 60s - warn: $this < 100 - crit: $this < 40 - delay: down 10m multiplier 1.5 max 1h - summary: APC UPS battery charge - info: APC UPS average battery charge over the last minute - to: sitemgr - - template: apcupsd_last_collected_secs - on: apcupsd.load - class: Latency - type: Power Supply -component: UPS device - calc: $now - $last_collected_t - every: 10s - units: seconds ago - warn: $this > (($status >= $WARNING) ? ($update_every) : ( 5 * $update_every)) - delay: down 5m multiplier 1.5 max 1h - summary: APC UPS last collection - info: APC UPS number of seconds since the last successful data collection - to: sitemgr - -#Send out a warning when SELFTEST code is BT or NG. Code descriptions can be found at: -#http://www.apcupsd.org/manual/#:~:text=or%20N/A.-,SELFTEST,-The%20results%20of - template: apcupsd_selftest_warning - on: apcupsd.selftest - lookup: max -1s unaligned match-names of BT,NG - units: status - every: 10s - warn: $this == 1 - delay: up 0 down 15m multiplier 1.5 max 1h - info: APC UPS self-test failed due to insufficient battery capacity or due to overload. - to: sitemgr - -#Send out a warning when STATUS code is ONBATT,OVERLOAD,LOWBATT,REPLACEBATT,NOBATT,COMMLOST -#https://man.archlinux.org/man/apcaccess.8.en#:~:text=apcupsd%20was%20started-,STATUS,-%3A%20UPS%20status.%20One - - template: apcupsd_status_onbatt - on: apcupsd.status - lookup: max -1s unaligned match-names of ONBATT - units: status - every: 10s - warn: $this == 1 - delay: up 1m down 15m multiplier 1.5 max 1h - info: APC UPS has switched to battery power because the input power has failed - to: sitemgr - - template: apcupsd_status_overload - on: apcupsd.status - lookup: max -1s unaligned match-names of OVERLOAD - units: status - every: 10s - warn: $this == 1 - delay: up 0 down 15m multiplier 1.5 max 1h - info: APC UPS is overloaded and cannot supply enough power to the load - to: sitemgr - - template: apcupsd_status_lowbatt - on: apcupsd.status - lookup: max -1s unaligned match-names of LOWBATT - units: status - every: 10s - warn: $this == 1 - delay: up 0 down 15m multiplier 1.5 max 1h - info: APC UPS battery is low and needs to be recharged - to: sitemgr - - template: apcupsd_status_replacebatt - on: apcupsd.status - lookup: max -1s unaligned match-names of REPLACEBATT - units: status - every: 10s - warn: $this == 1 - delay: up 0 down 15m multiplier 1.5 max 1h - info: APC UPS battery has reached the end of its lifespan and needs to be replaced - to: sitemgr - - template: apcupsd_status_nobatt - on: apcupsd.status - lookup: max -1s unaligned match-names of NOBATT - units: status - every: 10s - warn: $this == 1 - delay: up 0 down 15m multiplier 1.5 max 1h - info: APC UPS has no battery - to: sitemgr - - template: apcupsd_status_commlost - on: apcupsd.status - lookup: max -1s unaligned match-names of COMMLOST - units: status - every: 10s - warn: $this == 1 - delay: up 0 down 15m multiplier 1.5 max 1h - info: APC UPS communication link is lost - to: sitemgr |