summaryrefslogtreecommitdiffstats
path: root/plugins.d/README.md
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--plugins.d/README.md236
1 files changed, 0 insertions, 236 deletions
diff --git a/plugins.d/README.md b/plugins.d/README.md
deleted file mode 100644
index 35b9a2d9..00000000
--- a/plugins.d/README.md
+++ /dev/null
@@ -1,236 +0,0 @@
-netdata plugins
-===============
-
-Any program that can print a few values to its standard output can become
-a netdata plugin.
-
-There are 5 lines netdata parses. lines starting with:
-
-- `CHART` - create a new chart
-- `DIMENSION` - add a dimension to the chart just created
-- `BEGIN` - initialize data collection for a chart
-- `SET` - set the value of a dimension for the initialized chart
-- `END` - complete data collection for the initialized chart
-
-a single program can produce any number of charts with any number of dimensions
-each.
-
-charts can also be added any time (not just the beginning).
-
-### command line parameters
-
-The plugin should accept just **one** parameter: **the number of seconds it is
-expected to update the values for its charts**. The value passed by netdata
-to the plugin is controlled via its configuration file (so there is not need
-for the plugin to handle this configuration option).
-
-The script can overwrite the update frequency. For example, the server may
-request per second updates, but the script may overwrite this to one update
-every 5 seconds.
-
-### environment variables
-
-There are a few environment variables that are set by `netdata` and are
-available for the plugin to use.
-
-variable|description
-:------:|:----------
-`NETDATA_CONFIG_DIR`|The directory where all netdata related configuration should be stored. If the plugin requires custom configuration, this is the place to save it.
-`NETDATA_PLUGINS_DIR`|The directory where all netdata plugins are stored.
-`NETDATA_WEB_DIR`|The directory where the web files of netdata are saved.
-`NETDATA_CACHE_DIR`|The directory where the cache files of netdata are stored. Use this directory if the plugin requires a place to store data. A new directory should be created for the plugin for this purpose, inside this directory.
-`NETDATA_LOG_DIR`|The directory where the log files are stored. By default the `stderr` output of the plugin will be saved in the `error.log` file of netdata.
-`NETDATA_HOST_PREFIX`|This is used in environments where system directories like `/sys` and `/proc` have to be accessed at a different path.
-`NETDATA_DEBUG_FLAGS`|This is number (probably in hex starting with `0x`), that enables certain netdata debugging features.
-`NETDATA_UPDATE_EVERY`|The minimum number of seconds between chart refreshes. This is like the **internal clock** of netdata (it is user configurable, defaulting to `1`). There is no meaning for a plugin to update its values more frequently than this number of seconds.
-
-
-# the output of the plugin
-
-The plugin should output instructions for netdata to its output (`stdout`).
-
-## CHART
-
-`CHART` defines a new chart.
-
-the template is:
-
-> CHART type.id name title units [family [category [charttype [priority [update_every]]]]]
-
- where:
- - `type.id`
-
- uniquely identifies the chart,
- this is what will be needed to add values to the chart
-
- - `name`
-
- is the name that will be presented to the used for this chart
-
- - `title`
-
- the text above the chart
-
- - `units`
-
- the label of the vertical axis of the chart,
- all dimensions added to a chart should have the same units
- of measurement
-
- - `family`
-
- is used to group charts together
- (for example all eth0 charts should say: eth0),
- if empty or missing, the `id` part of `type.id` will be used
-
- - `category`
-
- the section under which the chart will appear
- (for example mem.ram should appear in the 'system' section),
- the special word 'none' means: do not show this chart on the home page,
- if empty or missing, the `type` part of `type.id` will be used
-
- - `charttype`
-
- one of `line`, `area` or `stacked`,
- if empty or missing, the `line` will be used
-
- - `priority`
-
- is the relative priority of the charts as rendered on the web page,
- lower numbers make the charts appear before the ones with higher numbers,
- if empty or missing, `1000` will be used
-
- - `update_every`
-
- overwrite the update frequency set by the server,
- if empty or missing, the user configured value will be used
-
-
-## DIMENSION
-
-`DIMENSION` defines a new dimension for the chart
-
-the template is:
-
-> DIMENSION id [name [algorithm [multiplier [divisor [hidden]]]]]
-
- where:
-
- - `id`
-
- the `id` of this dimension (it is a text value, not numeric),
- this will be needed later to add values to the dimension
-
- - `name`
-
- the name of the dimension as it will appear at the legend of the chart,
- if empty or missing the `id` will be used
-
- - `algorithm`
-
- one of:
-
- * `absolute`
-
- the value is to drawn as-is (interpolated to second boundary),
- if `algorithm` is empty, invalid or missing, `absolute` is used
-
- * `incremental`
-
- the value increases over time,
- the difference from the last value is presented in the chart,
- the server interpolates the value and calculates a per second figure
-
- * `percentage-of-absolute-row`
-
- the % of this value compared to the total of all dimensions
-
- * `percentage-of-incremental-row`
-
- the % of this value compared to the incremental total of
- all dimensions
-
- - `multiplier`
-
- an integer value to multiply the collected value,
- if empty or missing, `1` is used
-
- - `divisor`
-
- an integer value to divide the collected value,
- if empty or missing, `1` is used
-
- - `hidden`
-
- giving the keyword `hidden` will make this dimension hidden,
- it will take part in the calculations but will not be presented in the chart
-
-
-## data collection
-
-data collection is defined as a series of `BEGIN` -> `SET` -> `END` lines
-
-> BEGIN type.id [microseconds]
-
- - `type.id`
-
- is the unique identification of the chart (as given in `CHART`)
-
- - `microseconds`
-
- is the number of microseconds since the last update of the chart,
- it is optional.
-
- Under heavy system load, the system may have some latency transfering
- data from the plugins to netdata via the pipe. This number improves
- accuracy significantly, since the plugin is able to calculate the
- duration between its iterations better than netdata.
-
- The first time the plugin is started, no microseconds should be given
- to netdata.
-
-> SET id = value
-
- - `id`
-
- is the unique identification of the dimension (of the chart just began)
-
- - `value`
-
- is the collected value
-
-> END
-
- END does not take any parameters, it commits the collected values to the chart.
-
-More `SET` lines may appear to update all the dimensions of the chart.
-All of them in one `BEGIN` -> `END` block.
-
-All `SET` lines within a single `BEGIN` -> `END` block have to refer to the
-same chart.
-
-If more charts need to be updated, each chart should have its own
-`BEGIN` -> `SET` -> `END` block.
-
-If, for any reason, a plugin has issued a `BEGIN` but wants to cancel it,
-it can issue a `FLUSH`. The `FLUSH` command will instruct netdata to ignore
-the last `BEGIN` command.
-
-If a plugin does not behave properly (outputs invalid lines, or does not
-follow these guidelines), will be disabled by netdata.
-
-
-### collected values
-
-netdata will collect any **signed** value in the 64bit range:
-`-9.223.372.036.854.775.808` to `+9.223.372.036.854.775.807`
-
-Internally, all calculations are made using 128 bit double precision and are
-stored in 30 bits as floating point.
-
-If a value is not collected, leave it empty, like this:
-
-`SET id = `
-
-or do not output the line at all.