diff options
Diffstat (limited to '')
l--------- | src/collectors/charts.d.plugin/apcupsd/README.md (renamed from collectors/charts.d.plugin/apcupsd/README.md) | 0 | ||||
-rw-r--r-- | src/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh (renamed from collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh) | 0 | ||||
-rw-r--r-- | src/collectors/charts.d.plugin/apcupsd/apcupsd.conf (renamed from collectors/charts.d.plugin/apcupsd/apcupsd.conf) | 0 | ||||
-rw-r--r-- | src/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md (renamed from collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md) | 28 | ||||
-rw-r--r-- | src/collectors/charts.d.plugin/apcupsd/metadata.yaml | 256 |
5 files changed, 270 insertions, 14 deletions
diff --git a/collectors/charts.d.plugin/apcupsd/README.md b/src/collectors/charts.d.plugin/apcupsd/README.md index fc6681fe6..fc6681fe6 120000 --- a/collectors/charts.d.plugin/apcupsd/README.md +++ b/src/collectors/charts.d.plugin/apcupsd/README.md diff --git a/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh b/src/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh index da9cd19c3..da9cd19c3 100644 --- a/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh +++ b/src/collectors/charts.d.plugin/apcupsd/apcupsd.chart.sh diff --git a/collectors/charts.d.plugin/apcupsd/apcupsd.conf b/src/collectors/charts.d.plugin/apcupsd/apcupsd.conf index 679c0d61b..679c0d61b 100644 --- a/collectors/charts.d.plugin/apcupsd/apcupsd.conf +++ b/src/collectors/charts.d.plugin/apcupsd/apcupsd.conf diff --git a/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md b/src/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md index a5c1f9613..4e3aa3352 100644 --- a/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md +++ b/src/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md @@ -1,9 +1,9 @@ <!--startmeta -custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/charts.d.plugin/apcupsd/README.md" -meta_yaml: "https://github.com/netdata/netdata/edit/master/collectors/charts.d.plugin/apcupsd/metadata.yaml" +custom_edit_url: "https://github.com/netdata/netdata/edit/master/src/collectors/charts.d.plugin/apcupsd/README.md" +meta_yaml: "https://github.com/netdata/netdata/edit/master/src/collectors/charts.d.plugin/apcupsd/metadata.yaml" sidebar_label: "APC UPS" learn_status: "Published" -learn_rel_path: "Data Collection/UPS" +learn_rel_path: "Collecting Metrics/UPS" most_popular: False message: "DO NOT EDIT THIS FILE DIRECTLY, IT IS GENERATED BY THE COLLECTOR'S metadata.yaml FILE" endmeta--> @@ -85,16 +85,16 @@ The following alerts are available: | Alert name | On metric | Description | |:------------|:----------|:------------| -| [ apcupsd_ups_charge ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.charge | average UPS charge over the last minute | -| [ apcupsd_10min_ups_load ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.load | average UPS load over the last 10 minutes | -| [ apcupsd_last_collected_secs ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.load | number of seconds since the last successful data collection | -| [ apcupsd_selftest_warning ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.selftest | self-test failed due to insufficient battery capacity or due to overload. | -| [ apcupsd_status_onbatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS has switched to battery power because the input power has failed | -| [ apcupsd_status_overload ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS is overloaded and cannot supply enough power to the load | -| [ apcupsd_status_lowbatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS battery is low and needs to be recharged | -| [ apcupsd_status_replacebatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS battery has reached the end of its lifespan and needs to be replaced | -| [ apcupsd_status_nobatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS has no battery | -| [ apcupsd_status_commlost ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS communication link is lost | +| [ apcupsd_ups_charge ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.charge | average UPS charge over the last minute | +| [ apcupsd_10min_ups_load ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.load | average UPS load over the last 10 minutes | +| [ apcupsd_last_collected_secs ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.load | number of seconds since the last successful data collection | +| [ apcupsd_selftest_warning ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.selftest | self-test failed due to insufficient battery capacity or due to overload. | +| [ apcupsd_status_onbatt ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS has switched to battery power because the input power has failed | +| [ apcupsd_status_overload ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS is overloaded and cannot supply enough power to the load | +| [ apcupsd_status_lowbatt ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS battery is low and needs to be recharged | +| [ apcupsd_status_replacebatt ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS battery has reached the end of its lifespan and needs to be replaced | +| [ apcupsd_status_nobatt ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS has no battery | +| [ apcupsd_status_commlost ](https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS communication link is lost | ## Setup @@ -119,7 +119,7 @@ The configuration file name for this integration is `charts.d/apcupsd.conf`. You can edit the configuration file using the `edit-config` script from the -Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md#the-netdata-config-directory). +Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/netdata-agent/configuration.md#the-netdata-config-directory). ```bash cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata diff --git a/src/collectors/charts.d.plugin/apcupsd/metadata.yaml b/src/collectors/charts.d.plugin/apcupsd/metadata.yaml new file mode 100644 index 000000000..0af9c98e6 --- /dev/null +++ b/src/collectors/charts.d.plugin/apcupsd/metadata.yaml @@ -0,0 +1,256 @@ +plugin_name: charts.d.plugin +modules: + - meta: + plugin_name: charts.d.plugin + module_name: apcupsd + monitored_instance: + name: APC UPS + link: "https://www.apc.com" + categories: + - data-collection.ups + icon_filename: "apc.svg" + related_resources: + integrations: + list: [] + info_provided_to_referring_integrations: + description: "" + keywords: + - ups + - apc + - power + - supply + - battery + - apcupsd + most_popular: false + overview: + data_collection: + metrics_description: "Monitor APC UPS performance with Netdata for optimal uninterruptible power supply operations. Enhance your power supply reliability with real-time APC UPS metrics." + method_description: "The collector uses the `apcaccess` tool to contact the `apcupsd` daemon and get the APC UPS statistics." + supported_platforms: + include: [] + exclude: [] + multi_instance: false + additional_permissions: + description: "" + default_behavior: + auto_detection: + description: "By default, with no configuration provided, the collector will try to contact 127.0.0.1:3551 with using the `apcaccess` utility." + limits: + description: "" + performance_impact: + description: "" + setup: + prerequisites: + list: + - title: "Install charts.d plugin" + description: | + If [using our official native DEB/RPM packages](https://github.com/netdata/netdata/blob/master/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed. + - title: "Required software" + description: "Make sure the `apcaccess` and `apcupsd` are installed and running." + configuration: + file: + name: charts.d/apcupsd.conf + options: + description: | + The config file is sourced by the charts.d plugin. It's a standard bash file. + + The following collapsed table contains all the options that can be configured for the apcupsd collector. + folding: + title: "Config options" + enabled: true + list: + - name: apcupsd_sources + description: This is an array of apcupsd sources. You can have multiple entries there. Please refer to the example below on how to set it. + default_value: "127.0.0.1:3551" + required: false + - name: apcupsd_timeout + description: How long to wait for apcupsd to respond. + default_value: 3 + required: false + - name: apcupsd_update_every + description: The data collection frequency. If unset, will inherit the netdata update frequency. + default_value: 1 + required: false + - name: apcupsd_priority + description: The charts priority on the dashboard. + default_value: 90000 + required: false + - name: apcupsd_retries + description: The number of retries to do in case of failure before disabling the collector. + default_value: 10 + required: false + examples: + folding: + enabled: false + title: "Config" + list: + - name: Multiple apcupsd sources + description: Specify a multiple apcupsd sources along with a custom update interval + config: | + # add all your APC UPSes in this array - uncomment it too + declare -A apcupsd_sources=( + ["local"]="127.0.0.1:3551", + ["remote"]="1.2.3.4:3551" + ) + + # how long to wait for apcupsd to respond + #apcupsd_timeout=3 + + # the data collection frequency + # if unset, will inherit the netdata update frequency + apcupsd_update_every=5 + + # the charts priority on the dashboard + #apcupsd_priority=90000 + + # the number of retries to do in case of failure + # before disabling the module + #apcupsd_retries=10 + troubleshooting: + problems: + list: [] + alerts: + - name: apcupsd_ups_charge + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.charge + info: average UPS charge over the last minute + os: "*" + - name: apcupsd_10min_ups_load + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.load + info: average UPS load over the last 10 minutes + os: "*" + - name: apcupsd_last_collected_secs + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.load + info: number of seconds since the last successful data collection + - name: apcupsd_selftest_warning + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.selftest + info: self-test failed due to insufficient battery capacity or due to overload. + - name: apcupsd_status_onbatt + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS has switched to battery power because the input power has failed + - name: apcupsd_status_overload + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS is overloaded and cannot supply enough power to the load + - name: apcupsd_status_lowbatt + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS battery is low and needs to be recharged + - name: apcupsd_status_replacebatt + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS battery has reached the end of its lifespan and needs to be replaced + - name: apcupsd_status_nobatt + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS has no battery + - name: apcupsd_status_commlost + link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf + metric: apcupsd.status + info: APC UPS communication link is lost + metrics: + folding: + title: Metrics + enabled: false + description: "" + availability: [] + scopes: + - name: ups + description: "Metrics related to UPS. Each UPS provides its own set of the following metrics." + labels: [] + metrics: + - name: apcupsd.charge + description: UPS Charge + unit: "percentage" + chart_type: area + dimensions: + - name: charge + - name: apcupsd.battery.voltage + description: UPS Battery Voltage + unit: "Volts" + chart_type: line + dimensions: + - name: voltage + - name: nominal + - name: apcupsd.input.voltage + description: UPS Input Voltage + unit: "Volts" + chart_type: line + dimensions: + - name: voltage + - name: min + - name: max + - name: apcupsd.output.voltage + description: UPS Output Voltage + unit: "Volts" + chart_type: line + dimensions: + - name: absolute + - name: nominal + - name: apcupsd.input.frequency + description: UPS Input Voltage + unit: "Hz" + chart_type: line + dimensions: + - name: frequency + - name: apcupsd.load + description: UPS Load + unit: "percentage" + chart_type: area + dimensions: + - name: load + - name: apcupsd.load_usage + description: UPS Load Usage + unit: "Watts" + chart_type: area + dimensions: + - name: load + - name: apcupsd.temperature + description: UPS Temperature + unit: "Celsius" + chart_type: line + dimensions: + - name: temp + - name: apcupsd.time + description: UPS Time Remaining + unit: "Minutes" + chart_type: area + dimensions: + - name: time + - name: apcupsd.online + description: UPS ONLINE flag + unit: "boolean" + chart_type: line + dimensions: + - name: online + - name: apcupsd.selftest + description: UPS Self-Test status + unit: status + chart_type: line + dimensions: + - name: OK + - name: NO + - name: BT + - name: NG + - name: apcupsd.status + description: UPS Status + unit: status + chart_type: line + dimensions: + - name: ONLINE + - name: ONBATT + - name: OVERLOAD + - name: LOWBATT + - name: REPLACEBATT + - name: NOBATT + - name: SLAVE + - name: SLAVEDOWN + - name: COMMLOST + - name: CAL + - name: TRIM + - name: BOOST + - name: SHUTTING_DOWN |