summaryrefslogtreecommitdiffstats
path: root/src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json
diff options
context:
space:
mode:
Diffstat (limited to 'src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json')
-rw-r--r--src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json2260
1 files changed, 2260 insertions, 0 deletions
diff --git a/src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json b/src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json
new file mode 100644
index 000000000..02eefd719
--- /dev/null
+++ b/src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json
@@ -0,0 +1,2260 @@
+{
+ "Controllers": [
+ {
+ "Command Status": {
+ "CLI Version": "007.2703.0000.0000 July 03, 2023",
+ "Operating system": "Linux 6.9.4-dx",
+ "Controller": 0,
+ "Status": "Success",
+ "Description": "None"
+ },
+ "Response Data": {
+ "Basics": {
+ "Controller": 0,
+ "Adapter Type": " SAS3808(A0)",
+ "Model": "HBA 9500-8i",
+ "Serial Number": "REDACTED",
+ "Current System Date/time": "06/17/2024 18:39:45",
+ "Concurrent commands supported": 4992,
+ "SAS Address": " 500062b20828c940",
+ "PCI Address": "00:01:00:00"
+ },
+ "Version": {
+ "Firmware Package Build": "28.00.00.00",
+ "Firmware Version": "28.00.00.00",
+ "Bios Version": "09.55.00.00_28.00.00.00",
+ "NVDATA Version": "28.01.00.12",
+ "PSOC FW Version": "0x0064",
+ "PSOC Part Number": "14790",
+ "Driver Name": "mpt3sas",
+ "Driver Version": "48.100.00.00"
+ },
+ "PCI Version": {
+ "Vendor Id": 4096,
+ "Device Id": 230,
+ "SubVendor Id": 4096,
+ "SubDevice Id": 16512,
+ "Host Interface": "PCIE",
+ "Device Interface": "SAS-12G",
+ "Bus Number": 1,
+ "Device Number": 0,
+ "Function Number": 0,
+ "Domain ID": 0
+ },
+ "Pending Images in Flash": {
+ "Image name": "No pending images"
+ },
+ "Status": {
+ "Controller Status": "OK",
+ "Memory Correctable Errors": 0,
+ "Memory Uncorrectable Errors": 0,
+ "Bios was not detected during boot": "No",
+ "Controller has booted into safe mode": "No",
+ "Controller has booted into certificate provision mode": "No",
+ "Package Stamp Mismatch": "No"
+ },
+ "Supported Adapter Operations": {
+ "Alarm Control": "No",
+ "Cluster Support": "No",
+ "Self Diagnostic": "No",
+ "Deny SCSI Passthrough": "No",
+ "Deny SMP Passthrough": "No",
+ "Deny STP Passthrough": "No",
+ "Support more than 8 Phys": "Yes",
+ "FW and Event Time in GMT": "No",
+ "Support Enclosure Enumeration": "Yes",
+ "Support Allowed Operations": "Yes",
+ "Support Multipath": "Yes",
+ "Support Security": "Yes",
+ "Support Config Page Model": "No",
+ "Support the OCE without adding drives": "No",
+ "support EKM": "No",
+ "Snapshot Enabled": "No",
+ "Support PFK": "No",
+ "Support PI": "No",
+ "Support Shield State": "No",
+ "Support Set Link Speed": "No",
+ "Support JBOD": "No",
+ "Disable Online PFK Change": "No",
+ "Real Time Scheduler": "No",
+ "Support Reset Now": "No",
+ "Support Emulated Drives": "No",
+ "Support Secure Boot": "Yes",
+ "Support Platform Security": "No",
+ "Support Package Stamp Mismatch Reporting": "Yes",
+ "Support PSOC Update": "Yes",
+ "Support PSOC Part Information": "Yes",
+ "Support PSOC Version Information": "Yes"
+ },
+ "HwCfg": {
+ "ChipRevision": " A0",
+ "BatteryFRU": "N/A",
+ "Front End Port Count": 1,
+ "Backend Port Count": 11,
+ "Serial Debugger": "Absent",
+ "NVRAM Size": "0KB",
+ "Flash Size": "16MB",
+ "On Board Memory Size": "0MB",
+ "On Board Expander": "Absent",
+ "Temperature Sensor for ROC": "Present",
+ "Temperature Sensor for Controller": "Absent",
+ "Current Size of CacheCade (GB)": 0,
+ "Current Size of FW Cache (MB)": 0,
+ "ROC temperature(Degree Celsius)": 44
+ },
+ "Policies": {
+ "Policies Table": [
+ {
+ "Policy": "Predictive Fail Poll Interval",
+ "Current": "0 sec",
+ "Default": ""
+ },
+ {
+ "Policy": "Interrupt Throttle Active Count",
+ "Current": "0",
+ "Default": ""
+ },
+ {
+ "Policy": "Interrupt Throttle Completion",
+ "Current": "0 us",
+ "Default": ""
+ },
+ {
+ "Policy": "Rebuild Rate",
+ "Current": "0 %",
+ "Default": "30%"
+ },
+ {
+ "Policy": "PR Rate",
+ "Current": "0 %",
+ "Default": "30%"
+ },
+ {
+ "Policy": "BGI Rate",
+ "Current": "0 %",
+ "Default": "30%"
+ },
+ {
+ "Policy": "Check Consistency Rate",
+ "Current": "0 %",
+ "Default": "30%"
+ },
+ {
+ "Policy": "Reconstruction Rate",
+ "Current": "0 %",
+ "Default": "30%"
+ },
+ {
+ "Policy": "Cache Flush Interval",
+ "Current": "0s",
+ "Default": ""
+ }
+ ],
+ "Flush Time(Default)": "4s",
+ "Drive Coercion Mode": "none",
+ "Auto Rebuild": "Off",
+ "Battery Warning": "Off",
+ "ECC Bucket Size": 0,
+ "ECC Bucket Leak Rate (hrs)": 0,
+ "Restore HotSpare on Insertion": "Off",
+ "Expose Enclosure Devices": "Off",
+ "Maintain PD Fail History": "Off",
+ "Reorder Host Requests": "On",
+ "Auto detect BackPlane": "SGPIO/i2c SEP",
+ "Load Balance Mode": "None",
+ "Security Key Assigned": "Off",
+ "Disable Online Controller Reset": "Off",
+ "Use drive activity for locate": "Off"
+ },
+ "Boot": {
+ "Max Drives to Spinup at One Time": 2,
+ "Maximum number of direct attached drives to spin up in 1 min": 60,
+ "Delay Among Spinup Groups (sec)": 2,
+ "Allow Boot with Preserved Cache": "On"
+ },
+ "Defaults": {
+ "Phy Polarity": 0,
+ "Phy PolaritySplit": 0,
+ "Cached IO": "Off",
+ "Default spin down time (mins)": 0,
+ "Coercion Mode": "None",
+ "ZCR Config": "Unknown",
+ "Max Chained Enclosures": 0,
+ "Direct PD Mapping": "No",
+ "Restore Hot Spare on Insertion": "No",
+ "Expose Enclosure Devices": "No",
+ "Maintain PD Fail History": "No",
+ "Zero Based Enclosure Enumeration": "No",
+ "Disable Puncturing": "No",
+ "Un-Certified Hard Disk Drives": "Block",
+ "SMART Mode": "Mode 6",
+ "Enable LED Header": "No",
+ "LED Show Drive Activity": "No",
+ "Dirty LED Shows Drive Activity": "No",
+ "EnableCrashDump": "No",
+ "Disable Online Controller Reset": "No",
+ "Treat Single span R1E as R10": "No",
+ "Power Saving option": "Enable",
+ "TTY Log In Flash": "No",
+ "Auto Enhanced Import": "No",
+ "Enable Shield State": "No",
+ "Time taken to detect CME": "60 sec"
+ },
+ "Capabilities": {
+ "Supported Drives": "SAS, SATA, NVMe",
+ "Enable JBOD": "Yes",
+ "Max Parallel Commands": 4992,
+ "Max SGE Count": 128,
+ "Max Data Transfer Size": "32 sectors",
+ "Max Strips PerIO": 0,
+ "Max Configurable CacheCade Size": 0,
+ "Min Strip Size": "512Bytes",
+ "Max Strip Size": "512Bytes"
+ },
+ "Scheduled Tasks": "NA",
+ "Secure Boot": {
+ "Secure Boot Enabled": "Yes",
+ "Controller in Soft Secure Mode": "No",
+ "Controller in Hard Secure Mode": "Yes",
+ "Key Update Pending": "No",
+ "Remaining Secure Boot Key Slots": 7
+ },
+ "Security Protocol properties": {
+ "Security Protocol": "None"
+ },
+ "Enclosure Information": [
+ {
+ "EID": 23,
+ "State": "OK",
+ "Slots": 24,
+ "PD": 23,
+ "PS": 0,
+ "Fans": 0,
+ "TSs": 2,
+ "Alms": 0,
+ "SIM": 0,
+ "ProdID": "SC846-P",
+ "VendorSpecific": "x40-66.16.11.0"
+ },
+ {
+ "EID": 30,
+ "State": "OK",
+ "Slots": 12,
+ "PD": 6,
+ "PS": 0,
+ "Fans": 0,
+ "TSs": 2,
+ "Alms": 0,
+ "SIM": 0,
+ "ProdID": "SC826-P",
+ "VendorSpecific": "x28-66.16.11.0"
+ }
+ ],
+ "Physical Device Information": {
+ "Drive /c0/e23/s0": [
+ {
+ "EID:Slt": "23:0",
+ "DID": 0,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "12.732 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "ST14000NM001G-2KJ103",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s0 - Detailed Information": {
+ "Drive /c0/e23/s0 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s0 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "ST14000NM001G-2KJ103",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SN03 ",
+ "Raw size": "12.732 TB [0x65ddfffff Sectors]",
+ "Coerced size": "12.732 TB [0x65ddfffff Sectors]",
+ "Non Coerced size": "12.732 TB [0x65ddfffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 27344764927,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s0 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4540"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 4c 5a 4a 32 30 46 4b 34 00 00 00 00 00 00 4e 53 33 30 20 20 20 20 54 53 34 31 30 30 4e 30 30 4d 31 30 2d 47 4b 32 31 4a 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s1": [
+ {
+ "EID:Slt": "23:1",
+ "DID": 1,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "1.819 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WDS200T1R0A-68A4W0",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s1 - Detailed Information": {
+ "Drive /c0/e23/s1 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s1 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WDS200T1R0A-68A4W0",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "411000WR",
+ "Raw size": "1.819 TB [0xe8e088af Sectors]",
+ "Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Non Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 3907029167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s1 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4541"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 32 35 33 34 43 34 34 38 30 35 31 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s2": [
+ {
+ "EID:Slt": "23:2",
+ "DID": 2,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "16.370 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "ST18000NM000J-2TV103",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s2 - Detailed Information": {
+ "Drive /c0/e23/s2 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s2 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "ST18000NM000J-2TV103",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SN02 ",
+ "Raw size": "16.370 TB [0x82f7fffff Sectors]",
+ "Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 35156656127,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s2 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4542"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 47 57 50 30 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s3": [
+ {
+ "EID:Slt": "23:3",
+ "DID": 3,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "1.819 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WDS200T1R0A-68A4W0",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s3 - Detailed Information": {
+ "Drive /c0/e23/s3 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s3 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WDS200T1R0A-68A4W0",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "411000WR",
+ "Raw size": "1.819 TB [0xe8e088af Sectors]",
+ "Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Non Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 3907029167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s3 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4543"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 30 35 44 37 30 38 36 30 33 31 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s4": [
+ {
+ "EID:Slt": "23:4",
+ "DID": 4,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "10.913 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "4 KB",
+ "Model": "HGST HUH721212ALN604",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s4 - Detailed Information": {
+ "Drive /c0/e23/s4 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s4 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "HGST HUH721212ALN604",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "LEGNW925",
+ "Raw size": "10.913 TB [0xae9fffff Sectors]",
+ "Coerced size": "10.913 TB [0xae9fffff Sectors]",
+ "Non Coerced size": "10.913 TB [0xae9fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "4 KB",
+ "Config ID": "NA",
+ "Number of Blocks": 2929721343,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s4 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4544"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 35 35 4a 34 44 42 32 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 45 4c 4e 47 39 57 35 32 47 48 54 53 48 20 48 55 32 37 32 31 32 31 4c 41 36 4e 34 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 02 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s5": [
+ {
+ "EID:Slt": "23:5",
+ "DID": 5,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "894.252 GB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "KINGSTON SEDC500R960G",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s5 - Detailed Information": {
+ "Drive /c0/e23/s5 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s5 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "KINGSTON SEDC500R960G",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SCEKJ2.7",
+ "Raw size": "894.252 GB [0x6fc81aaf Sectors]",
+ "Coerced size": "894.252 GB [0x6fc81aaf Sectors]",
+ "Non Coerced size": "894.252 GB [0x6fc81aaf Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 1875385007,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s5 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4545"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 41 41 41 32 45 45 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 32 4a 37 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 35 43 30 30 39 52 30 36 20 47 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s6": [
+ {
+ "EID:Slt": "23:6",
+ "DID": 6,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "12.732 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "ST14000NM001G-2KJ103",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s6 - Detailed Information": {
+ "Drive /c0/e23/s6 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s6 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "ST14000NM001G-2KJ103",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SN03 ",
+ "Raw size": "12.732 TB [0x65ddfffff Sectors]",
+ "Coerced size": "12.732 TB [0x65ddfffff Sectors]",
+ "Non Coerced size": "12.732 TB [0x65ddfffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 27344764927,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s6 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4546"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 4c 5a 48 32 31 4a 50 44 00 00 00 00 00 00 4e 53 33 30 20 20 20 20 54 53 34 31 30 30 4e 30 30 4d 31 30 2d 47 4b 32 31 4a 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s7": [
+ {
+ "EID:Slt": "23:7",
+ "DID": 7,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "1.819 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "Seagate BarraCuda 120 SSD ZA2000CM10003",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s7 - Detailed Information": {
+ "Drive /c0/e23/s7 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s7 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "Seagate BarraCuda 120 SSD ZA2000CM10003",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "STZSE014",
+ "Raw size": "1.819 TB [0xe8e088af Sectors]",
+ "Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Non Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 3907029167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s7 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4547"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 37 30 58 44 30 45 35 20 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 00 00 54 53 53 5a 30 45 34 31 65 53 67 61 74 61 20 65 61 42 72 72 43 61 64 75 20 61 32 31 20 30 53 53 20 44 41 5a 30 32 30 30 4d 43 30 31 30 30 20 33 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s8": [
+ {
+ "EID:Slt": "23:8",
+ "DID": 8,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "16.370 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "ST18000NM000J-2TV103",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s8 - Detailed Information": {
+ "Drive /c0/e23/s8 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s8 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "ST18000NM000J-2TV103",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SN02 ",
+ "Raw size": "16.370 TB [0x82f7fffff Sectors]",
+ "Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 35156656127,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s8 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4548"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 44 5a 36 54 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s9": [
+ {
+ "EID:Slt": "23:9",
+ "DID": 9,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "1.819 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WDS200T1R0A-68A4W0",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s9 - Detailed Information": {
+ "Drive /c0/e23/s9 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s9 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WDS200T1R0A-68A4W0",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "411000WR",
+ "Raw size": "1.819 TB [0xe8e088af Sectors]",
+ "Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Non Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 3907029167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s9 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4549"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 36 34 57 36 30 38 33 30 31 34 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s10": [
+ {
+ "EID:Slt": "23:10",
+ "DID": 10,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "10.913 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "4 KB",
+ "Model": "HGST HUH721212ALN604",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s10 - Detailed Information": {
+ "Drive /c0/e23/s10 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s10 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "HGST HUH721212ALN604",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "LEGNW925",
+ "Raw size": "10.913 TB [0xae9fffff Sectors]",
+ "Coerced size": "10.913 TB [0xae9fffff Sectors]",
+ "Non Coerced size": "10.913 TB [0xae9fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "4 KB",
+ "Config ID": "NA",
+ "Number of Blocks": 2929721343,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s10 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db454a"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 35 42 48 4b 52 42 42 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 45 4c 4e 47 39 57 35 32 47 48 54 53 48 20 48 55 32 37 32 31 32 31 4c 41 36 4e 34 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 02 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s11": [
+ {
+ "EID:Slt": "23:11",
+ "DID": 11,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "894.252 GB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "KINGSTON SEDC500R960G",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s11 - Detailed Information": {
+ "Drive /c0/e23/s11 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s11 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "KINGSTON SEDC500R960G",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SCEKJ2.7",
+ "Raw size": "894.252 GB [0x6fc81aaf Sectors]",
+ "Coerced size": "894.252 GB [0x6fc81aaf Sectors]",
+ "Non Coerced size": "894.252 GB [0x6fc81aaf Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 1875385007,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s11 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db454b"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 41 41 41 32 38 44 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 32 4a 37 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 35 43 30 30 39 52 30 36 20 47 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s12": [
+ {
+ "EID:Slt": "23:12",
+ "DID": 12,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "3.492 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "KINGSTON SEDC600M3840G",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s12 - Detailed Information": {
+ "Drive /c0/e23/s12 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s12 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "KINGSTON SEDC600M3840G",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SCEKH5.1",
+ "Raw size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 7501476527,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s12 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db455c"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 38 46 32 44 39 43 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s14": [
+ {
+ "EID:Slt": "23:14",
+ "DID": 13,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "16.370 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "ST18000NM000J-2TV103",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s14 - Detailed Information": {
+ "Drive /c0/e23/s14 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s14 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "ST18000NM000J-2TV103",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SN02 ",
+ "Raw size": "16.370 TB [0x82f7fffff Sectors]",
+ "Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 35156656127,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s14 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db455e"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 4e 54 35 36 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s15": [
+ {
+ "EID:Slt": "23:15",
+ "DID": 14,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "1.819 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WDS200T1R0A-68A4W0",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s15 - Detailed Information": {
+ "Drive /c0/e23/s15 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s15 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WDS200T1R0A-68A4W0",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "411000WR",
+ "Raw size": "1.819 TB [0xe8e088af Sectors]",
+ "Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Non Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 3907029167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s15 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db455f"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 36 34 57 36 30 38 33 30 36 33 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s16": [
+ {
+ "EID:Slt": "23:16",
+ "DID": 15,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "10.913 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "4 KB",
+ "Model": "HGST HUH721212ALN604",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s16 - Detailed Information": {
+ "Drive /c0/e23/s16 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s16 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "HGST HUH721212ALN604",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "LEGNW925",
+ "Raw size": "10.913 TB [0xae9fffff Sectors]",
+ "Coerced size": "10.913 TB [0xae9fffff Sectors]",
+ "Non Coerced size": "10.913 TB [0xae9fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "4 KB",
+ "Config ID": "NA",
+ "Number of Blocks": 2929721343,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s16 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4560"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 35 34 4a 5a 4b 42 4a 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 45 4c 4e 47 39 57 35 32 47 48 54 53 48 20 48 55 32 37 32 31 32 31 4c 41 36 4e 34 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 02 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s17": [
+ {
+ "EID:Slt": "23:17",
+ "DID": 16,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "931.512 GB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WDS100T1R0A-68A4W0",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s17 - Detailed Information": {
+ "Drive /c0/e23/s17 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s17 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WDS100T1R0A-68A4W0",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "411000WR",
+ "Raw size": "931.512 GB [0x74706daf Sectors]",
+ "Coerced size": "931.512 GB [0x74706daf Sectors]",
+ "Non Coerced size": "931.512 GB [0x74706daf Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 1953525167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s17 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4561"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 32 33 31 45 46 34 34 34 39 34 31 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 31 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s18": [
+ {
+ "EID:Slt": "23:18",
+ "DID": 17,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "3.492 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "KINGSTON SEDC600M3840G",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s18 - Detailed Information": {
+ "Drive /c0/e23/s18 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s18 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "KINGSTON SEDC600M3840G",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SCEKH5.1",
+ "Raw size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 7501476527,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s18 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4562"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 44 46 43 35 42 34 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s19": [
+ {
+ "EID:Slt": "23:19",
+ "DID": 18,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "931.512 GB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "Seagate IronWolf ZA1000NM10002-2ZG102",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s19 - Detailed Information": {
+ "Drive /c0/e23/s19 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s19 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "Seagate IronWolf ZA1000NM10002-2ZG102",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SU3SC013",
+ "Raw size": "931.512 GB [0x74706daf Sectors]",
+ "Coerced size": "931.512 GB [0x74706daf Sectors]",
+ "Non Coerced size": "931.512 GB [0x74706daf Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 1953525167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s19 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4563"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 54 37 30 43 35 30 32 57 20 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 00 00 55 53 53 33 30 43 33 31 65 53 67 61 74 61 20 65 72 49 6e 6f 6f 57 66 6c 5a 20 31 41 30 30 4e 30 31 4d 30 30 32 30 32 2d 47 5a 30 31 20 32 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s20": [
+ {
+ "EID:Slt": "23:20",
+ "DID": 19,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "16.370 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "ST18000NM000J-2TV103",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s20 - Detailed Information": {
+ "Drive /c0/e23/s20 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s20 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "ST18000NM000J-2TV103",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SN02 ",
+ "Raw size": "16.370 TB [0x82f7fffff Sectors]",
+ "Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 35156656127,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s20 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4564"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 34 59 4a 54 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s21": [
+ {
+ "EID:Slt": "23:21",
+ "DID": 20,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "1.819 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WDS200T1R0A-68A4W0",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s21 - Detailed Information": {
+ "Drive /c0/e23/s21 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s21 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WDS200T1R0A-68A4W0",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "411000WR",
+ "Raw size": "1.819 TB [0xe8e088af Sectors]",
+ "Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Non Coerced size": "1.819 TB [0xe8e088af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 3907029167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s21 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4565"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 38 32 34 35 34 34 33 31 32 30 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s22": [
+ {
+ "EID:Slt": "23:22",
+ "DID": 21,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "10.913 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "ST12000NM001G-2MV103",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s22 - Detailed Information": {
+ "Drive /c0/e23/s22 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s22 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "ST12000NM001G-2MV103",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SN03 ",
+ "Raw size": "10.913 TB [0x574ffffff Sectors]",
+ "Coerced size": "10.913 TB [0x574ffffff Sectors]",
+ "Non Coerced size": "10.913 TB [0x574ffffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 23437770751,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s22 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4566"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 4c 57 30 32 47 36 50 58 00 00 00 00 00 00 4e 53 33 30 20 20 20 20 54 53 32 31 30 30 4e 30 30 4d 31 30 2d 47 4d 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e23/s23": [
+ {
+ "EID:Slt": "23:23",
+ "DID": 22,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "931.512 GB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WDS100T1R0A-68A4W0",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e23/s23 - Detailed Information": {
+ "Drive /c0/e23/s23 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e23/s23 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WDS100T1R0A-68A4W0",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "411000WR",
+ "Raw size": "931.512 GB [0x74706daf Sectors]",
+ "Coerced size": "931.512 GB [0x74706daf Sectors]",
+ "Non Coerced size": "931.512 GB [0x74706daf Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 1953525167,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e23/s23 Policies/Settings": {
+ "Enclosure position": "0",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020db4567"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 32 33 31 45 46 34 34 36 35 35 30 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 31 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e30/s3": [
+ {
+ "EID:Slt": "30:3",
+ "DID": 24,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "18.189 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WUH722020BLE6L4",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e30/s3 - Detailed Information": {
+ "Drive /c0/e30/s3 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e30/s3 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WUH722020BLE6L4",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "PQGNW540",
+ "Raw size": "18.189 TB [0x9185fffff Sectors]",
+ "Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Non Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 39063650303,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e30/s3 Policies/Settings": {
+ "Enclosure position": "1",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020e87d43"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 4c 38 34 47 48 56 41 59 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 51 50 4e 47 35 57 30 34 44 57 20 43 57 20 48 55 32 37 30 32 30 32 4c 42 36 45 34 4c 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e30/s5": [
+ {
+ "EID:Slt": "30:5",
+ "DID": 25,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "18.189 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "WDC WUH722020BLE6L4",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e30/s5 - Detailed Information": {
+ "Drive /c0/e30/s5 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e30/s5 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "WDC WUH722020BLE6L4",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "PQGNW540",
+ "Raw size": "18.189 TB [0x9185fffff Sectors]",
+ "Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Non Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 39063650303,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e30/s5 Policies/Settings": {
+ "Enclosure position": "1",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020e87d45"
+ }
+ ]
+ },
+ "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 4c 38 34 47 52 56 41 4c 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 51 50 4e 47 35 57 30 34 44 57 20 43 57 20 48 55 32 37 30 32 30 32 4c 42 36 45 34 4c 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e30/s6": [
+ {
+ "EID:Slt": "30:6",
+ "DID": 26,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "18.189 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "TOSHIBA MG10ACA20TE",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e30/s6 - Detailed Information": {
+ "Drive /c0/e30/s6 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e30/s6 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "TOSHIBA MG10ACA20TE",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "0102 ",
+ "Raw size": "18.189 TB [0x9185fffff Sectors]",
+ "Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Non Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 39063650303,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e30/s6 Policies/Settings": {
+ "Enclosure position": "1",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020e87d46"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 32 5a 30 42 30 41 5a 33 34 46 4a 4d 00 00 00 00 00 00 31 30 32 30 20 20 20 20 4f 54 48 53 42 49 20 41 47 4d 30 31 43 41 32 41 54 30 20 45 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 07 00 07 00 "
+ },
+ "Drive /c0/e30/s8": [
+ {
+ "EID:Slt": "30:8",
+ "DID": 27,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "18.189 TB",
+ "Intf": "SATA",
+ "Med": "HDD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "TOSHIBA MG10ACA20TE",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e30/s8 - Detailed Information": {
+ "Drive /c0/e30/s8 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e30/s8 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "TOSHIBA MG10ACA20TE",
+ "NAND Vendor": "NA",
+ "SN": " REDACTED",
+ "WWN": "REDACTED",
+ "Firmware Revision": "0102 ",
+ "Raw size": "18.189 TB [0x9185fffff Sectors]",
+ "Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Non Coerced size": "18.189 TB [0x9185fffff Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 39063650303,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e30/s8 Policies/Settings": {
+ "Enclosure position": "1",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020e87d48"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 32 5a 30 41 31 41 35 4b 34 46 4a 4d 00 00 00 00 00 00 31 30 32 30 20 20 20 20 4f 54 48 53 42 49 20 41 47 4d 30 31 43 41 32 41 54 30 20 45 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 07 00 07 00 "
+ },
+ "Drive /c0/e30/s9": [
+ {
+ "EID:Slt": "30:9",
+ "DID": 28,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "3.492 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "KINGSTON SEDC600M3840G",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e30/s9 - Detailed Information": {
+ "Drive /c0/e30/s9 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e30/s9 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "KINGSTON SEDC600M3840G",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SCEKH5.1",
+ "Raw size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 7501476527,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e30/s9 Policies/Settings": {
+ "Enclosure position": "1",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020e87d49"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 44 46 43 35 42 42 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ },
+ "Drive /c0/e30/s11": [
+ {
+ "EID:Slt": "30:11",
+ "DID": 29,
+ "State": "JBOD",
+ "DG": "-",
+ "Size": "3.492 TB",
+ "Intf": "SATA",
+ "Med": "SSD",
+ "SED": "-",
+ "PI": "-",
+ "SeSz": "512B",
+ "Model": "KINGSTON SEDC600M3840G",
+ "Sp": "-"
+ }
+ ],
+ "Drive /c0/e30/s11 - Detailed Information": {
+ "Drive /c0/e30/s11 State": {
+ "Shield Counter": "N/A",
+ "Media Error Count": "N/A",
+ "Other Error Count": "N/A",
+ "Predictive Failure Count": "N/A",
+ "S.M.A.R.T alert flagged by drive": "N/A"
+ },
+ "Drive /c0/e30/s11 Device attributes": {
+ "Manufacturer Id": "ATA ",
+ "Model Number": "KINGSTON SEDC600M3840G",
+ "NAND Vendor": "NA",
+ "SN": "REDACTED ",
+ "WWN": "REDACTED",
+ "Firmware Revision": "SCEKH5.1",
+ "Raw size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]",
+ "Device Speed": "6.0Gb/s",
+ "Link Speed": "12.0Gb/s",
+ "NCQ setting": "N/A",
+ "Sector Size": "512B",
+ "Config ID": "NA",
+ "Number of Blocks": 7501476527,
+ "Connector Name": "C0 & C1 "
+ },
+ "Drive /c0/e30/s11 Policies/Settings": {
+ "Enclosure position": "1",
+ "Connected Port Number": "0(path0) ",
+ "Sequence Number": 0,
+ "Commissioned Spare": "No",
+ "Emergency Spare": "No",
+ "Last Predictive Failure Event Sequence Number": "N/A",
+ "Successful diagnostics completion on": "N/A",
+ "SED Capable": "N/A",
+ "SED Enabled": "N/A",
+ "Secured": "N/A",
+ "Needs EKM Attention": "N/A",
+ "PI Eligible": "N/A",
+ "Certified": "N/A",
+ "Wide Port Capable": "N/A",
+ "Multipath": "No",
+ "Port Information": [
+ {
+ "Port": 0,
+ "Status": "Active",
+ "Linkspeed": "12.0Gb/s",
+ "SAS address": "0x5003048020e87d4b"
+ }
+ ]
+ },
+ "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 38 46 32 44 37 34 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 "
+ }
+ }
+ }
+ }
+ ]
+}
+