diff options
Diffstat (limited to 'src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json')
-rw-r--r-- | src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json | 2260 |
1 files changed, 2260 insertions, 0 deletions
diff --git a/src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json b/src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json new file mode 100644 index 000000000..02eefd719 --- /dev/null +++ b/src/go/collectors/go.d.plugin/modules/storcli/testdata/mpt3sas-controllers-info.json @@ -0,0 +1,2260 @@ +{ + "Controllers": [ + { + "Command Status": { + "CLI Version": "007.2703.0000.0000 July 03, 2023", + "Operating system": "Linux 6.9.4-dx", + "Controller": 0, + "Status": "Success", + "Description": "None" + }, + "Response Data": { + "Basics": { + "Controller": 0, + "Adapter Type": " SAS3808(A0)", + "Model": "HBA 9500-8i", + "Serial Number": "REDACTED", + "Current System Date/time": "06/17/2024 18:39:45", + "Concurrent commands supported": 4992, + "SAS Address": " 500062b20828c940", + "PCI Address": "00:01:00:00" + }, + "Version": { + "Firmware Package Build": "28.00.00.00", + "Firmware Version": "28.00.00.00", + "Bios Version": "09.55.00.00_28.00.00.00", + "NVDATA Version": "28.01.00.12", + "PSOC FW Version": "0x0064", + "PSOC Part Number": "14790", + "Driver Name": "mpt3sas", + "Driver Version": "48.100.00.00" + }, + "PCI Version": { + "Vendor Id": 4096, + "Device Id": 230, + "SubVendor Id": 4096, + "SubDevice Id": 16512, + "Host Interface": "PCIE", + "Device Interface": "SAS-12G", + "Bus Number": 1, + "Device Number": 0, + "Function Number": 0, + "Domain ID": 0 + }, + "Pending Images in Flash": { + "Image name": "No pending images" + }, + "Status": { + "Controller Status": "OK", + "Memory Correctable Errors": 0, + "Memory Uncorrectable Errors": 0, + "Bios was not detected during boot": "No", + "Controller has booted into safe mode": "No", + "Controller has booted into certificate provision mode": "No", + "Package Stamp Mismatch": "No" + }, + "Supported Adapter Operations": { + "Alarm Control": "No", + "Cluster Support": "No", + "Self Diagnostic": "No", + "Deny SCSI Passthrough": "No", + "Deny SMP Passthrough": "No", + "Deny STP Passthrough": "No", + "Support more than 8 Phys": "Yes", + "FW and Event Time in GMT": "No", + "Support Enclosure Enumeration": "Yes", + "Support Allowed Operations": "Yes", + "Support Multipath": "Yes", + "Support Security": "Yes", + "Support Config Page Model": "No", + "Support the OCE without adding drives": "No", + "support EKM": "No", + "Snapshot Enabled": "No", + "Support PFK": "No", + "Support PI": "No", + "Support Shield State": "No", + "Support Set Link Speed": "No", + "Support JBOD": "No", + "Disable Online PFK Change": "No", + "Real Time Scheduler": "No", + "Support Reset Now": "No", + "Support Emulated Drives": "No", + "Support Secure Boot": "Yes", + "Support Platform Security": "No", + "Support Package Stamp Mismatch Reporting": "Yes", + "Support PSOC Update": "Yes", + "Support PSOC Part Information": "Yes", + "Support PSOC Version Information": "Yes" + }, + "HwCfg": { + "ChipRevision": " A0", + "BatteryFRU": "N/A", + "Front End Port Count": 1, + "Backend Port Count": 11, + "Serial Debugger": "Absent", + "NVRAM Size": "0KB", + "Flash Size": "16MB", + "On Board Memory Size": "0MB", + "On Board Expander": "Absent", + "Temperature Sensor for ROC": "Present", + "Temperature Sensor for Controller": "Absent", + "Current Size of CacheCade (GB)": 0, + "Current Size of FW Cache (MB)": 0, + "ROC temperature(Degree Celsius)": 44 + }, + "Policies": { + "Policies Table": [ + { + "Policy": "Predictive Fail Poll Interval", + "Current": "0 sec", + "Default": "" + }, + { + "Policy": "Interrupt Throttle Active Count", + "Current": "0", + "Default": "" + }, + { + "Policy": "Interrupt Throttle Completion", + "Current": "0 us", + "Default": "" + }, + { + "Policy": "Rebuild Rate", + "Current": "0 %", + "Default": "30%" + }, + { + "Policy": "PR Rate", + "Current": "0 %", + "Default": "30%" + }, + { + "Policy": "BGI Rate", + "Current": "0 %", + "Default": "30%" + }, + { + "Policy": "Check Consistency Rate", + "Current": "0 %", + "Default": "30%" + }, + { + "Policy": "Reconstruction Rate", + "Current": "0 %", + "Default": "30%" + }, + { + "Policy": "Cache Flush Interval", + "Current": "0s", + "Default": "" + } + ], + "Flush Time(Default)": "4s", + "Drive Coercion Mode": "none", + "Auto Rebuild": "Off", + "Battery Warning": "Off", + "ECC Bucket Size": 0, + "ECC Bucket Leak Rate (hrs)": 0, + "Restore HotSpare on Insertion": "Off", + "Expose Enclosure Devices": "Off", + "Maintain PD Fail History": "Off", + "Reorder Host Requests": "On", + "Auto detect BackPlane": "SGPIO/i2c SEP", + "Load Balance Mode": "None", + "Security Key Assigned": "Off", + "Disable Online Controller Reset": "Off", + "Use drive activity for locate": "Off" + }, + "Boot": { + "Max Drives to Spinup at One Time": 2, + "Maximum number of direct attached drives to spin up in 1 min": 60, + "Delay Among Spinup Groups (sec)": 2, + "Allow Boot with Preserved Cache": "On" + }, + "Defaults": { + "Phy Polarity": 0, + "Phy PolaritySplit": 0, + "Cached IO": "Off", + "Default spin down time (mins)": 0, + "Coercion Mode": "None", + "ZCR Config": "Unknown", + "Max Chained Enclosures": 0, + "Direct PD Mapping": "No", + "Restore Hot Spare on Insertion": "No", + "Expose Enclosure Devices": "No", + "Maintain PD Fail History": "No", + "Zero Based Enclosure Enumeration": "No", + "Disable Puncturing": "No", + "Un-Certified Hard Disk Drives": "Block", + "SMART Mode": "Mode 6", + "Enable LED Header": "No", + "LED Show Drive Activity": "No", + "Dirty LED Shows Drive Activity": "No", + "EnableCrashDump": "No", + "Disable Online Controller Reset": "No", + "Treat Single span R1E as R10": "No", + "Power Saving option": "Enable", + "TTY Log In Flash": "No", + "Auto Enhanced Import": "No", + "Enable Shield State": "No", + "Time taken to detect CME": "60 sec" + }, + "Capabilities": { + "Supported Drives": "SAS, SATA, NVMe", + "Enable JBOD": "Yes", + "Max Parallel Commands": 4992, + "Max SGE Count": 128, + "Max Data Transfer Size": "32 sectors", + "Max Strips PerIO": 0, + "Max Configurable CacheCade Size": 0, + "Min Strip Size": "512Bytes", + "Max Strip Size": "512Bytes" + }, + "Scheduled Tasks": "NA", + "Secure Boot": { + "Secure Boot Enabled": "Yes", + "Controller in Soft Secure Mode": "No", + "Controller in Hard Secure Mode": "Yes", + "Key Update Pending": "No", + "Remaining Secure Boot Key Slots": 7 + }, + "Security Protocol properties": { + "Security Protocol": "None" + }, + "Enclosure Information": [ + { + "EID": 23, + "State": "OK", + "Slots": 24, + "PD": 23, + "PS": 0, + "Fans": 0, + "TSs": 2, + "Alms": 0, + "SIM": 0, + "ProdID": "SC846-P", + "VendorSpecific": "x40-66.16.11.0" + }, + { + "EID": 30, + "State": "OK", + "Slots": 12, + "PD": 6, + "PS": 0, + "Fans": 0, + "TSs": 2, + "Alms": 0, + "SIM": 0, + "ProdID": "SC826-P", + "VendorSpecific": "x28-66.16.11.0" + } + ], + "Physical Device Information": { + "Drive /c0/e23/s0": [ + { + "EID:Slt": "23:0", + "DID": 0, + "State": "JBOD", + "DG": "-", + "Size": "12.732 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "ST14000NM001G-2KJ103", + "Sp": "-" + } + ], + "Drive /c0/e23/s0 - Detailed Information": { + "Drive /c0/e23/s0 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s0 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "ST14000NM001G-2KJ103", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "SN03 ", + "Raw size": "12.732 TB [0x65ddfffff Sectors]", + "Coerced size": "12.732 TB [0x65ddfffff Sectors]", + "Non Coerced size": "12.732 TB [0x65ddfffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 27344764927, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s0 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4540" + } + ] + }, + "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 4c 5a 4a 32 30 46 4b 34 00 00 00 00 00 00 4e 53 33 30 20 20 20 20 54 53 34 31 30 30 4e 30 30 4d 31 30 2d 47 4b 32 31 4a 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s1": [ + { + "EID:Slt": "23:1", + "DID": 1, + "State": "JBOD", + "DG": "-", + "Size": "1.819 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WDS200T1R0A-68A4W0", + "Sp": "-" + } + ], + "Drive /c0/e23/s1 - Detailed Information": { + "Drive /c0/e23/s1 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s1 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WDS200T1R0A-68A4W0", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "411000WR", + "Raw size": "1.819 TB [0xe8e088af Sectors]", + "Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Non Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 3907029167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s1 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4541" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 32 35 33 34 43 34 34 38 30 35 31 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s2": [ + { + "EID:Slt": "23:2", + "DID": 2, + "State": "JBOD", + "DG": "-", + "Size": "16.370 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "ST18000NM000J-2TV103", + "Sp": "-" + } + ], + "Drive /c0/e23/s2 - Detailed Information": { + "Drive /c0/e23/s2 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s2 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "ST18000NM000J-2TV103", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "SN02 ", + "Raw size": "16.370 TB [0x82f7fffff Sectors]", + "Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 35156656127, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s2 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4542" + } + ] + }, + "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 47 57 50 30 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s3": [ + { + "EID:Slt": "23:3", + "DID": 3, + "State": "JBOD", + "DG": "-", + "Size": "1.819 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WDS200T1R0A-68A4W0", + "Sp": "-" + } + ], + "Drive /c0/e23/s3 - Detailed Information": { + "Drive /c0/e23/s3 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s3 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WDS200T1R0A-68A4W0", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "411000WR", + "Raw size": "1.819 TB [0xe8e088af Sectors]", + "Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Non Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 3907029167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s3 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4543" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 30 35 44 37 30 38 36 30 33 31 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s4": [ + { + "EID:Slt": "23:4", + "DID": 4, + "State": "JBOD", + "DG": "-", + "Size": "10.913 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "4 KB", + "Model": "HGST HUH721212ALN604", + "Sp": "-" + } + ], + "Drive /c0/e23/s4 - Detailed Information": { + "Drive /c0/e23/s4 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s4 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "HGST HUH721212ALN604", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "LEGNW925", + "Raw size": "10.913 TB [0xae9fffff Sectors]", + "Coerced size": "10.913 TB [0xae9fffff Sectors]", + "Non Coerced size": "10.913 TB [0xae9fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "4 KB", + "Config ID": "NA", + "Number of Blocks": 2929721343, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s4 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4544" + } + ] + }, + "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 35 35 4a 34 44 42 32 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 45 4c 4e 47 39 57 35 32 47 48 54 53 48 20 48 55 32 37 32 31 32 31 4c 41 36 4e 34 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 02 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s5": [ + { + "EID:Slt": "23:5", + "DID": 5, + "State": "JBOD", + "DG": "-", + "Size": "894.252 GB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "KINGSTON SEDC500R960G", + "Sp": "-" + } + ], + "Drive /c0/e23/s5 - Detailed Information": { + "Drive /c0/e23/s5 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s5 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "KINGSTON SEDC500R960G", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "SCEKJ2.7", + "Raw size": "894.252 GB [0x6fc81aaf Sectors]", + "Coerced size": "894.252 GB [0x6fc81aaf Sectors]", + "Non Coerced size": "894.252 GB [0x6fc81aaf Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 1875385007, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s5 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4545" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 41 41 41 32 45 45 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 32 4a 37 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 35 43 30 30 39 52 30 36 20 47 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s6": [ + { + "EID:Slt": "23:6", + "DID": 6, + "State": "JBOD", + "DG": "-", + "Size": "12.732 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "ST14000NM001G-2KJ103", + "Sp": "-" + } + ], + "Drive /c0/e23/s6 - Detailed Information": { + "Drive /c0/e23/s6 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s6 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "ST14000NM001G-2KJ103", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "SN03 ", + "Raw size": "12.732 TB [0x65ddfffff Sectors]", + "Coerced size": "12.732 TB [0x65ddfffff Sectors]", + "Non Coerced size": "12.732 TB [0x65ddfffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 27344764927, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s6 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4546" + } + ] + }, + "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 4c 5a 48 32 31 4a 50 44 00 00 00 00 00 00 4e 53 33 30 20 20 20 20 54 53 34 31 30 30 4e 30 30 4d 31 30 2d 47 4b 32 31 4a 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s7": [ + { + "EID:Slt": "23:7", + "DID": 7, + "State": "JBOD", + "DG": "-", + "Size": "1.819 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "Seagate BarraCuda 120 SSD ZA2000CM10003", + "Sp": "-" + } + ], + "Drive /c0/e23/s7 - Detailed Information": { + "Drive /c0/e23/s7 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s7 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "Seagate BarraCuda 120 SSD ZA2000CM10003", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "STZSE014", + "Raw size": "1.819 TB [0xe8e088af Sectors]", + "Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Non Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 3907029167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s7 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4547" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 37 30 58 44 30 45 35 20 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 00 00 54 53 53 5a 30 45 34 31 65 53 67 61 74 61 20 65 61 42 72 72 43 61 64 75 20 61 32 31 20 30 53 53 20 44 41 5a 30 32 30 30 4d 43 30 31 30 30 20 33 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s8": [ + { + "EID:Slt": "23:8", + "DID": 8, + "State": "JBOD", + "DG": "-", + "Size": "16.370 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "ST18000NM000J-2TV103", + "Sp": "-" + } + ], + "Drive /c0/e23/s8 - Detailed Information": { + "Drive /c0/e23/s8 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s8 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "ST18000NM000J-2TV103", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "SN02 ", + "Raw size": "16.370 TB [0x82f7fffff Sectors]", + "Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 35156656127, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s8 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4548" + } + ] + }, + "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 44 5a 36 54 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s9": [ + { + "EID:Slt": "23:9", + "DID": 9, + "State": "JBOD", + "DG": "-", + "Size": "1.819 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WDS200T1R0A-68A4W0", + "Sp": "-" + } + ], + "Drive /c0/e23/s9 - Detailed Information": { + "Drive /c0/e23/s9 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s9 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WDS200T1R0A-68A4W0", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "411000WR", + "Raw size": "1.819 TB [0xe8e088af Sectors]", + "Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Non Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 3907029167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s9 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4549" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 36 34 57 36 30 38 33 30 31 34 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s10": [ + { + "EID:Slt": "23:10", + "DID": 10, + "State": "JBOD", + "DG": "-", + "Size": "10.913 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "4 KB", + "Model": "HGST HUH721212ALN604", + "Sp": "-" + } + ], + "Drive /c0/e23/s10 - Detailed Information": { + "Drive /c0/e23/s10 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s10 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "HGST HUH721212ALN604", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "LEGNW925", + "Raw size": "10.913 TB [0xae9fffff Sectors]", + "Coerced size": "10.913 TB [0xae9fffff Sectors]", + "Non Coerced size": "10.913 TB [0xae9fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "4 KB", + "Config ID": "NA", + "Number of Blocks": 2929721343, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s10 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db454a" + } + ] + }, + "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 35 42 48 4b 52 42 42 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 45 4c 4e 47 39 57 35 32 47 48 54 53 48 20 48 55 32 37 32 31 32 31 4c 41 36 4e 34 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 02 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s11": [ + { + "EID:Slt": "23:11", + "DID": 11, + "State": "JBOD", + "DG": "-", + "Size": "894.252 GB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "KINGSTON SEDC500R960G", + "Sp": "-" + } + ], + "Drive /c0/e23/s11 - Detailed Information": { + "Drive /c0/e23/s11 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s11 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "KINGSTON SEDC500R960G", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "SCEKJ2.7", + "Raw size": "894.252 GB [0x6fc81aaf Sectors]", + "Coerced size": "894.252 GB [0x6fc81aaf Sectors]", + "Non Coerced size": "894.252 GB [0x6fc81aaf Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 1875385007, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s11 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db454b" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 41 41 41 32 38 44 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 32 4a 37 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 35 43 30 30 39 52 30 36 20 47 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s12": [ + { + "EID:Slt": "23:12", + "DID": 12, + "State": "JBOD", + "DG": "-", + "Size": "3.492 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "KINGSTON SEDC600M3840G", + "Sp": "-" + } + ], + "Drive /c0/e23/s12 - Detailed Information": { + "Drive /c0/e23/s12 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s12 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "KINGSTON SEDC600M3840G", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "SCEKH5.1", + "Raw size": "3.492 TB [0x1bf1f72af Sectors]", + "Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 7501476527, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s12 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db455c" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 38 46 32 44 39 43 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s14": [ + { + "EID:Slt": "23:14", + "DID": 13, + "State": "JBOD", + "DG": "-", + "Size": "16.370 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "ST18000NM000J-2TV103", + "Sp": "-" + } + ], + "Drive /c0/e23/s14 - Detailed Information": { + "Drive /c0/e23/s14 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s14 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "ST18000NM000J-2TV103", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "SN02 ", + "Raw size": "16.370 TB [0x82f7fffff Sectors]", + "Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 35156656127, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s14 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db455e" + } + ] + }, + "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 4e 54 35 36 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s15": [ + { + "EID:Slt": "23:15", + "DID": 14, + "State": "JBOD", + "DG": "-", + "Size": "1.819 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WDS200T1R0A-68A4W0", + "Sp": "-" + } + ], + "Drive /c0/e23/s15 - Detailed Information": { + "Drive /c0/e23/s15 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s15 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WDS200T1R0A-68A4W0", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "411000WR", + "Raw size": "1.819 TB [0xe8e088af Sectors]", + "Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Non Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 3907029167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s15 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db455f" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 36 34 57 36 30 38 33 30 36 33 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s16": [ + { + "EID:Slt": "23:16", + "DID": 15, + "State": "JBOD", + "DG": "-", + "Size": "10.913 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "4 KB", + "Model": "HGST HUH721212ALN604", + "Sp": "-" + } + ], + "Drive /c0/e23/s16 - Detailed Information": { + "Drive /c0/e23/s16 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s16 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "HGST HUH721212ALN604", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "LEGNW925", + "Raw size": "10.913 TB [0xae9fffff Sectors]", + "Coerced size": "10.913 TB [0xae9fffff Sectors]", + "Non Coerced size": "10.913 TB [0xae9fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "4 KB", + "Config ID": "NA", + "Number of Blocks": 2929721343, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s16 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4560" + } + ] + }, + "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 51 35 34 4a 5a 4b 42 4a 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 45 4c 4e 47 39 57 35 32 47 48 54 53 48 20 48 55 32 37 32 31 32 31 4c 41 36 4e 34 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 02 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s17": [ + { + "EID:Slt": "23:17", + "DID": 16, + "State": "JBOD", + "DG": "-", + "Size": "931.512 GB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WDS100T1R0A-68A4W0", + "Sp": "-" + } + ], + "Drive /c0/e23/s17 - Detailed Information": { + "Drive /c0/e23/s17 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s17 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WDS100T1R0A-68A4W0", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "411000WR", + "Raw size": "931.512 GB [0x74706daf Sectors]", + "Coerced size": "931.512 GB [0x74706daf Sectors]", + "Non Coerced size": "931.512 GB [0x74706daf Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 1953525167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s17 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4561" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 32 33 31 45 46 34 34 34 39 34 31 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 31 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s18": [ + { + "EID:Slt": "23:18", + "DID": 17, + "State": "JBOD", + "DG": "-", + "Size": "3.492 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "KINGSTON SEDC600M3840G", + "Sp": "-" + } + ], + "Drive /c0/e23/s18 - Detailed Information": { + "Drive /c0/e23/s18 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s18 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "KINGSTON SEDC600M3840G", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "SCEKH5.1", + "Raw size": "3.492 TB [0x1bf1f72af Sectors]", + "Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 7501476527, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s18 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4562" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 44 46 43 35 42 34 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s19": [ + { + "EID:Slt": "23:19", + "DID": 18, + "State": "JBOD", + "DG": "-", + "Size": "931.512 GB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "Seagate IronWolf ZA1000NM10002-2ZG102", + "Sp": "-" + } + ], + "Drive /c0/e23/s19 - Detailed Information": { + "Drive /c0/e23/s19 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s19 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "Seagate IronWolf ZA1000NM10002-2ZG102", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "SU3SC013", + "Raw size": "931.512 GB [0x74706daf Sectors]", + "Coerced size": "931.512 GB [0x74706daf Sectors]", + "Non Coerced size": "931.512 GB [0x74706daf Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 1953525167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s19 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4563" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 54 37 30 43 35 30 32 57 20 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 00 00 55 53 53 33 30 43 33 31 65 53 67 61 74 61 20 65 72 49 6e 6f 6f 57 66 6c 5a 20 31 41 30 30 4e 30 31 4d 30 30 32 30 32 2d 47 5a 30 31 20 32 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s20": [ + { + "EID:Slt": "23:20", + "DID": 19, + "State": "JBOD", + "DG": "-", + "Size": "16.370 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "ST18000NM000J-2TV103", + "Sp": "-" + } + ], + "Drive /c0/e23/s20 - Detailed Information": { + "Drive /c0/e23/s20 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s20 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "ST18000NM000J-2TV103", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "SN02 ", + "Raw size": "16.370 TB [0x82f7fffff Sectors]", + "Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Non Coerced size": "16.370 TB [0x82f7fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 35156656127, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s20 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4564" + } + ] + }, + "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 52 5a 33 35 34 59 4a 54 00 00 00 00 00 00 4e 53 32 30 20 20 20 20 54 53 38 31 30 30 4e 30 30 4d 30 30 2d 4a 54 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s21": [ + { + "EID:Slt": "23:21", + "DID": 20, + "State": "JBOD", + "DG": "-", + "Size": "1.819 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WDS200T1R0A-68A4W0", + "Sp": "-" + } + ], + "Drive /c0/e23/s21 - Detailed Information": { + "Drive /c0/e23/s21 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s21 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WDS200T1R0A-68A4W0", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "411000WR", + "Raw size": "1.819 TB [0xe8e088af Sectors]", + "Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Non Coerced size": "1.819 TB [0xe8e088af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 3907029167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s21 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4565" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 31 32 38 32 34 35 34 34 33 31 32 30 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 32 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s22": [ + { + "EID:Slt": "23:22", + "DID": 21, + "State": "JBOD", + "DG": "-", + "Size": "10.913 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "ST12000NM001G-2MV103", + "Sp": "-" + } + ], + "Drive /c0/e23/s22 - Detailed Information": { + "Drive /c0/e23/s22 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s22 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "ST12000NM001G-2MV103", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "SN03 ", + "Raw size": "10.913 TB [0x574ffffff Sectors]", + "Coerced size": "10.913 TB [0x574ffffff Sectors]", + "Non Coerced size": "10.913 TB [0x574ffffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 23437770751, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s22 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4566" + } + ] + }, + "Inquiry Data": "5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20 4c 57 30 32 47 36 50 58 00 00 00 00 00 00 4e 53 33 30 20 20 20 20 54 53 32 31 30 30 4e 30 30 4d 31 30 2d 47 4d 32 31 56 33 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e23/s23": [ + { + "EID:Slt": "23:23", + "DID": 22, + "State": "JBOD", + "DG": "-", + "Size": "931.512 GB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WDS100T1R0A-68A4W0", + "Sp": "-" + } + ], + "Drive /c0/e23/s23 - Detailed Information": { + "Drive /c0/e23/s23 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e23/s23 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WDS100T1R0A-68A4W0", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "411000WR", + "Raw size": "931.512 GB [0x74706daf Sectors]", + "Coerced size": "931.512 GB [0x74706daf Sectors]", + "Non Coerced size": "931.512 GB [0x74706daf Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 1953525167, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e23/s23 Policies/Settings": { + "Enclosure position": "0", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020db4567" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 32 33 31 45 46 34 34 36 35 35 30 20 20 20 20 20 20 20 20 00 00 00 00 00 00 31 34 30 31 30 30 52 57 44 57 20 43 57 20 53 44 30 31 54 30 52 31 41 30 36 2d 41 38 57 34 20 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80 00 40 00 2f 00 40 00 02 00 00 06 00 ff 3f 10 00 3f 00 10 fc fb 00 01 91 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e30/s3": [ + { + "EID:Slt": "30:3", + "DID": 24, + "State": "JBOD", + "DG": "-", + "Size": "18.189 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WUH722020BLE6L4", + "Sp": "-" + } + ], + "Drive /c0/e30/s3 - Detailed Information": { + "Drive /c0/e30/s3 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e30/s3 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WUH722020BLE6L4", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "PQGNW540", + "Raw size": "18.189 TB [0x9185fffff Sectors]", + "Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Non Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 39063650303, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e30/s3 Policies/Settings": { + "Enclosure position": "1", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020e87d43" + } + ] + }, + "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 4c 38 34 47 48 56 41 59 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 51 50 4e 47 35 57 30 34 44 57 20 43 57 20 48 55 32 37 30 32 30 32 4c 42 36 45 34 4c 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e30/s5": [ + { + "EID:Slt": "30:5", + "DID": 25, + "State": "JBOD", + "DG": "-", + "Size": "18.189 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "WDC WUH722020BLE6L4", + "Sp": "-" + } + ], + "Drive /c0/e30/s5 - Detailed Information": { + "Drive /c0/e30/s5 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e30/s5 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "WDC WUH722020BLE6L4", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "PQGNW540", + "Raw size": "18.189 TB [0x9185fffff Sectors]", + "Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Non Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 39063650303, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e30/s5 Policies/Settings": { + "Enclosure position": "1", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020e87d45" + } + ] + }, + "Inquiry Data": "5a 04 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 4c 38 34 47 52 56 41 4c 20 20 20 20 20 20 20 20 20 20 20 20 03 00 00 00 38 00 51 50 4e 47 35 57 30 34 44 57 20 43 57 20 48 55 32 37 30 32 30 32 4c 42 36 45 34 4c 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00 3f 00 10 fc fb 00 00 59 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e30/s6": [ + { + "EID:Slt": "30:6", + "DID": 26, + "State": "JBOD", + "DG": "-", + "Size": "18.189 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "TOSHIBA MG10ACA20TE", + "Sp": "-" + } + ], + "Drive /c0/e30/s6 - Detailed Information": { + "Drive /c0/e30/s6 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e30/s6 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "TOSHIBA MG10ACA20TE", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "0102 ", + "Raw size": "18.189 TB [0x9185fffff Sectors]", + "Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Non Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 39063650303, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e30/s6 Policies/Settings": { + "Enclosure position": "1", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020e87d46" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 32 5a 30 42 30 41 5a 33 34 46 4a 4d 00 00 00 00 00 00 31 30 32 30 20 20 20 20 4f 54 48 53 42 49 20 41 47 4d 30 31 43 41 32 41 54 30 20 45 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 07 00 07 00 " + }, + "Drive /c0/e30/s8": [ + { + "EID:Slt": "30:8", + "DID": 27, + "State": "JBOD", + "DG": "-", + "Size": "18.189 TB", + "Intf": "SATA", + "Med": "HDD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "TOSHIBA MG10ACA20TE", + "Sp": "-" + } + ], + "Drive /c0/e30/s8 - Detailed Information": { + "Drive /c0/e30/s8 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e30/s8 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "TOSHIBA MG10ACA20TE", + "NAND Vendor": "NA", + "SN": " REDACTED", + "WWN": "REDACTED", + "Firmware Revision": "0102 ", + "Raw size": "18.189 TB [0x9185fffff Sectors]", + "Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Non Coerced size": "18.189 TB [0x9185fffff Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 39063650303, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e30/s8 Policies/Settings": { + "Enclosure position": "1", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020e87d48" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 20 20 20 20 20 20 20 20 32 5a 30 41 31 41 35 4b 34 46 4a 4d 00 00 00 00 00 00 31 30 32 30 20 20 20 20 4f 54 48 53 42 49 20 41 47 4d 30 31 43 41 32 41 54 30 20 45 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 02 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 5d ff ff ff 0f 07 00 07 00 " + }, + "Drive /c0/e30/s9": [ + { + "EID:Slt": "30:9", + "DID": 28, + "State": "JBOD", + "DG": "-", + "Size": "3.492 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "KINGSTON SEDC600M3840G", + "Sp": "-" + } + ], + "Drive /c0/e30/s9 - Detailed Information": { + "Drive /c0/e30/s9 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e30/s9 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "KINGSTON SEDC600M3840G", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "SCEKH5.1", + "Raw size": "3.492 TB [0x1bf1f72af Sectors]", + "Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 7501476527, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e30/s9 Policies/Settings": { + "Enclosure position": "1", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020e87d49" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 44 46 43 35 42 42 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + }, + "Drive /c0/e30/s11": [ + { + "EID:Slt": "30:11", + "DID": 29, + "State": "JBOD", + "DG": "-", + "Size": "3.492 TB", + "Intf": "SATA", + "Med": "SSD", + "SED": "-", + "PI": "-", + "SeSz": "512B", + "Model": "KINGSTON SEDC600M3840G", + "Sp": "-" + } + ], + "Drive /c0/e30/s11 - Detailed Information": { + "Drive /c0/e30/s11 State": { + "Shield Counter": "N/A", + "Media Error Count": "N/A", + "Other Error Count": "N/A", + "Predictive Failure Count": "N/A", + "S.M.A.R.T alert flagged by drive": "N/A" + }, + "Drive /c0/e30/s11 Device attributes": { + "Manufacturer Id": "ATA ", + "Model Number": "KINGSTON SEDC600M3840G", + "NAND Vendor": "NA", + "SN": "REDACTED ", + "WWN": "REDACTED", + "Firmware Revision": "SCEKH5.1", + "Raw size": "3.492 TB [0x1bf1f72af Sectors]", + "Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Non Coerced size": "3.492 TB [0x1bf1f72af Sectors]", + "Device Speed": "6.0Gb/s", + "Link Speed": "12.0Gb/s", + "NCQ setting": "N/A", + "Sector Size": "512B", + "Config ID": "NA", + "Number of Blocks": 7501476527, + "Connector Name": "C0 & C1 " + }, + "Drive /c0/e30/s11 Policies/Settings": { + "Enclosure position": "1", + "Connected Port Number": "0(path0) ", + "Sequence Number": 0, + "Commissioned Spare": "No", + "Emergency Spare": "No", + "Last Predictive Failure Event Sequence Number": "N/A", + "Successful diagnostics completion on": "N/A", + "SED Capable": "N/A", + "SED Enabled": "N/A", + "Secured": "N/A", + "Needs EKM Attention": "N/A", + "PI Eligible": "N/A", + "Certified": "N/A", + "Wide Port Capable": "N/A", + "Multipath": "No", + "Port Information": [ + { + "Port": 0, + "Status": "Active", + "Linkspeed": "12.0Gb/s", + "SAS address": "0x5003048020e87d4b" + } + ] + }, + "Inquiry Data": "40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00 00 00 00 00 30 35 32 30 42 36 32 37 32 38 38 46 32 44 37 34 20 20 20 20 00 00 00 00 00 00 43 53 4b 45 35 48 31 2e 49 4b 47 4e 54 53 4e 4f 53 20 44 45 36 43 30 30 33 4d 34 38 47 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80 00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00 3f 00 10 fc fb 00 10 01 ff ff ff 0f 00 00 07 00 " + } + } + } + } + ] +} + |