From a8220ab2d293bb7f4b014b79d16b2fb05090fa93 Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Sun, 7 Feb 2021 12:45:55 +0100 Subject: Adding upstream version 1.29.0. Signed-off-by: Daniel Baumann --- health/health.d/scaleio.conf | 38 ++++++++++++++++++++++++++++++++++++++ 1 file changed, 38 insertions(+) create mode 100644 health/health.d/scaleio.conf (limited to 'health/health.d/scaleio.conf') diff --git a/health/health.d/scaleio.conf b/health/health.d/scaleio.conf new file mode 100644 index 000000000..1a3088a2a --- /dev/null +++ b/health/health.d/scaleio.conf @@ -0,0 +1,38 @@ + +# make sure scaleio is running + +template: scaleio_last_collected_secs + on: scaleio.system_capacity_total + calc: $now - $last_collected_t + units: seconds ago + every: 10s + warn: $this > (($status >= $WARNING) ? ($update_every) : ( 5 * $update_every)) + crit: $this > (($status == $CRITICAL) ? ($update_every) : (60 * $update_every)) + delay: down 5m multiplier 1.5 max 1h + info: number of seconds since the last successful data collection + to: sysadmin + +# make sure Storage Pool capacity utilization is under limit + +template: scaleio_storage_pool_capacity_utilization + on: scaleio.storage_pool_capacity_utilization + calc: $used + units: % + every: 10s + warn: $this > (($status >= $WARNING) ? (80) : (90)) + crit: $this > (($status == $CRITICAL) ? (90) : (98)) + delay: down 15m multiplier 1.5 max 1h + info: Storage Pool capacity utilization + to: sysadmin + + +# make sure Sdc is connected to MDM + +template: scaleio_sdc_mdm_connection_state + on: scaleio.sdc_mdm_connection_state + calc: $connected + every: 10s + warn: $this != 1 + delay: up 30s down 5m multiplier 1.5 max 1h + info: Sdc connection to MDM state + to: sysadmin -- cgit v1.2.3