From b485aab7e71c1625cfc27e0f92c9509f42378458 Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Sun, 5 May 2024 13:19:16 +0200 Subject: Adding upstream version 1.45.3+dfsg. Signed-off-by: Daniel Baumann --- src/health/guides/mdstat/mdstat_mismatch_cnt.md | 15 +++++++++++++++ 1 file changed, 15 insertions(+) create mode 100644 src/health/guides/mdstat/mdstat_mismatch_cnt.md (limited to 'src/health/guides/mdstat/mdstat_mismatch_cnt.md') diff --git a/src/health/guides/mdstat/mdstat_mismatch_cnt.md b/src/health/guides/mdstat/mdstat_mismatch_cnt.md new file mode 100644 index 000000000..7a156e38f --- /dev/null +++ b/src/health/guides/mdstat/mdstat_mismatch_cnt.md @@ -0,0 +1,15 @@ +### Understand the alert + +This alert presents the number of unsynchronized blocks for the RAID array in crisis. Receiving this alert indicates a high number of unsynchronized blocks for the RAID array. This might indicate that data on the array is corrupted. + +This alert is raised to warning when the metric exceeds 1024 unsynchronized blocks. + +### Troubleshoot the alert + +There is no standard approach to troubleshooting this alert because the reasons can be various. + +For example, one of the reasons might be a swap on the array, which is relatively harmless. However, this alert can also be triggered by hardware issues which can lead to many problems and inconsistencies between the disks. + +### Useful resources + +[Serverfault | Reasons for high mismatch_cnt on a RAID1/10 array](https://serverfault.com/questions/885565/what-are-raid-1-10-mismatch-cnt-0-causes-except-for-swap-file/885574#885574) -- cgit v1.2.3