plugin_name: charts.d.plugin modules: - meta: plugin_name: charts.d.plugin module_name: apcupsd monitored_instance: name: APC UPS link: "https://www.apc.com" categories: - data-collection.ups icon_filename: "apc.svg" related_resources: integrations: list: [] info_provided_to_referring_integrations: description: "" keywords: - ups - apc - power - supply - battery - apcupsd most_popular: false overview: data_collection: metrics_description: "Monitor APC UPS performance with Netdata for optimal uninterruptible power supply operations. Enhance your power supply reliability with real-time APC UPS metrics." method_description: "The collector uses the `apcaccess` tool to contact the `apcupsd` daemon and get the APC UPS statistics." supported_platforms: include: [] exclude: [] multi_instance: false additional_permissions: description: "" default_behavior: auto_detection: description: "By default, with no configuration provided, the collector will try to contact 127.0.0.1:3551 with using the `apcaccess` utility." limits: description: "" performance_impact: description: "" setup: prerequisites: list: - title: "Required software" description: "Make sure the `apcaccess` and `apcupsd` are installed and running." configuration: file: name: charts.d/apcupsd.conf options: description: | The config file is sourced by the charts.d plugin. It's a standard bash file. The following collapsed table contains all the options that can be configured for the apcupsd collector. folding: title: "Config options" enabled: true list: - name: apcupsd_sources description: This is an array of apcupsd sources. You can have multiple entries there. Please refer to the example below on how to set it. default_value: "127.0.0.1:3551" required: false - name: apcupsd_timeout description: How long to wait for apcupsd to respond. default_value: 3 required: false - name: apcupsd_update_every description: The data collection frequency. If unset, will inherit the netdata update frequency. default_value: 1 required: false - name: apcupsd_priority description: The charts priority on the dashboard. default_value: 90000 required: false - name: apcupsd_retries description: The number of retries to do in case of failure before disabling the collector. default_value: 10 required: false examples: folding: enabled: false title: "Config" list: - name: Multiple apcupsd sources description: Specify a multiple apcupsd sources along with a custom update interval config: | # add all your APC UPSes in this array - uncomment it too declare -A apcupsd_sources=( ["local"]="127.0.0.1:3551", ["remote"]="1.2.3.4:3551" ) # how long to wait for apcupsd to respond #apcupsd_timeout=3 # the data collection frequency # if unset, will inherit the netdata update frequency apcupsd_update_every=5 # the charts priority on the dashboard #apcupsd_priority=90000 # the number of retries to do in case of failure # before disabling the module #apcupsd_retries=10 troubleshooting: problems: list: [] alerts: - name: apcupsd_ups_charge link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf metric: apcupsd.charge info: average UPS charge over the last minute os: "*" - name: apcupsd_10min_ups_load link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf metric: apcupsd.load info: average UPS load over the last 10 minutes os: "*" - name: apcupsd_last_collected_secs link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf metric: apcupsd.load info: number of seconds since the last successful data collection metrics: folding: title: Metrics enabled: false description: "" availability: [] scopes: - name: ups description: "Metrics related to UPS. Each UPS provides its own set of the following metrics." labels: [] metrics: - name: apcupsd.charge description: UPS Charge unit: "percentage" chart_type: area dimensions: - name: charge - name: apcupsd.battery.voltage description: UPS Battery Voltage unit: "Volts" chart_type: line dimensions: - name: voltage - name: nominal - name: apcupsd.input.voltage description: UPS Input Voltage unit: "Volts" chart_type: line dimensions: - name: voltage - name: min - name: max - name: apcupsd.output.voltage description: UPS Output Voltage unit: "Volts" chart_type: line dimensions: - name: absolute - name: nominal - name: apcupsd.input.frequency description: UPS Input Voltage unit: "Hz" chart_type: line dimensions: - name: frequency - name: apcupsd.load description: UPS Load unit: "percentage" chart_type: area dimensions: - name: load - name: apcupsd.load_usage description: UPS Load Usage unit: "Watts" chart_type: area dimensions: - name: load - name: apcupsd.temperature description: UPS Temperature unit: "Celsius" chart_type: line dimensions: - name: temp - name: apcupsd.time description: UPS Time Remaining unit: "Minutes" chart_type: area dimensions: - name: time - name: apcupsd.online description: UPS ONLINE flag unit: "boolean" chart_type: line dimensions: - name: online