# you can disable an alarm notification by setting the 'to' line to: silent template: adaptec_raid_ld_health_status on: adaptecraid.logical_device_status class: Errors type: System component: RAID lookup: average -1m unaligned percentage of ok units: % every: 10s crit: $this < 100 delay: down 5m multiplier 1.5 max 1h summary: Adaptec RAID LD (number ${label:ld_number}) health status info: Adaptec RAID logical device (number ${label:ld_number} name ${label:ld_name}) health status is critical to: sysadmin template: adaptec_raid_pd_health_state on: adaptecraid.physical_device_state class: Errors type: System component: RAID lookup: average -1m unaligned percentage of ok units: % every: 10s crit: $this < 100 delay: down 5m multiplier 1.5 max 1h summary: Adaptec RAID PD (number ${label:pd_number}) health state info: Adaptec RAID physical device (number ${label:pd_number} location ${label:location}) health state is critical to: sysadmin