# you can disable an alarm notification by setting the 'to' line to: silent # Warn on any compute errors encountered. template: boinc_compute_errors on: boinc.states class: Errors type: Computing component: BOINC lookup: average -10m unaligned of comperror units: tasks every: 1m warn: $this > 0 delay: up 1m down 5m multiplier 1.5 max 1h summary: BOINC compute errors info: Average number of compute errors over the last 10 minutes to: sysadmin # Warn on lots of upload errors template: boinc_upload_errors on: boinc.states class: Errors type: Computing component: BOINC lookup: average -10m unaligned of upload_failed units: tasks every: 1m warn: $this > 0 delay: up 1m down 5m multiplier 1.5 max 1h summary: BOINC failed uploads info: Average number of failed uploads over the last 10 minutes to: sysadmin # Warn on the task queue being empty template: boinc_total_tasks on: boinc.tasks class: Utilization type: Computing component: BOINC lookup: average -10m unaligned of total units: tasks every: 1m warn: $this < 1 delay: up 5m down 10m multiplier 1.5 max 1h summary: BOINC total tasks info: Average number of total tasks over the last 10 minutes to: sysadmin # Warn on no active tasks with a non-empty queue template: boinc_active_tasks on: boinc.tasks class: Utilization type: Computing component: BOINC lookup: average -10m unaligned of active calc: ($boinc_total_tasks >= 1) ? ($this) : (inf) units: tasks every: 1m warn: $this < 1 delay: up 5m down 10m multiplier 1.5 max 1h summary: BOINC active tasks info: Average number of active tasks over the last 10 minutes to: sysadmin