# you can disable an alarm notification by setting the 'to' line to: silent template: lvm_lv_data_space_utilization on: lvm.lv_data_space_utilization class: Utilization type: System component: LVM calc: $utilization units: % every: 1m warn: $this > (($status >= $WARNING ) ? (85) : (90)) crit: ($this > (($status == $CRITICAL) ? (90) : (98))) delay: down 5m multiplier 1.5 max 1h summary: LVM LV ${label:lv_name} on VG ${label:vg_name} high data space usage info: LVM logical volume high data space usage (LV ${label:lv_name} VG ${label:vg_name} Type ${label:volume_type}) to: sysadmin template: lvm_lv_metadata_space_utilization on: lvm.lv_metadata_space_utilization class: Utilization type: System component: LVM calc: $utilization units: % every: 1m warn: $this > (($status >= $WARNING ) ? (85) : (90)) crit: ($this > (($status == $CRITICAL) ? (90) : (98))) delay: down 5m multiplier 1.5 max 1h summary: LVM LV ${label:lv_name} on VG ${label:vg_name} high metadata space usage info: LVM logical volume high metadata space usage (LV ${label:lv_name} VG ${label:vg_name} Type ${label:volume_type}) to: sysadmin