1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
|
<!--
title: "freeipmi.plugin"
custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/freeipmi.plugin/README.md"
sidebar_label: "freeipmi.plugin"
learn_status: "Published"
learn_topic_type: "References"
learn_rel_path: "Integrations/Monitor/Devices"
-->
# freeipmi.plugin
Netdata has a [freeipmi](https://www.gnu.org/software/freeipmi/) plugin.
> FreeIPMI provides in-band and out-of-band IPMI software based on the IPMI v1.5/2.0 specification. The IPMI specification defines a set of interfaces for platform management and is implemented by a number vendors for system management. The features of IPMI that most users will be interested in are sensor monitoring, system event monitoring, power control, and serial-over-LAN (SOL).
## Installing the FreeIPMI plugin
When using our official DEB/RPM packages, the FreeIPMI plugin is included in a separate package named
`netdata-plugin-freeipmi` which needs to be manually installed using your system package manager. It is not
installed automatically due to the large number of dependencies it requires.
When using a static build of Netdata, the FreeIPMI plugin will be included and installed automatically, though
you will still need to have FreeIPMI installed on your system to be able to use the plugin.
When using a local build of Netdata, you need to ensure that the FreeIPMI development packages (typically called `libipmimonitoring-dev`, `libipmimonitoring-devel`, or `freeipmi-devel`) are installed when building Netdata.
### Special Considerations
Accessing IPMI requires root access, so the FreeIPMI plugin is automatically installed setuid root.
FreeIPMI does not work correctly on IBM POWER systems, thus Netdata’s FreeIPMI plugin is not usable on such systems.
If you have not previously used IPMI on your system, you will probably need to run the `ipmimonitoring` command as root to initiailze IPMI settings so that the Netdata plugin works correctly. It should return information about available seensors on the system.
In some distributions `libipmimonitoring.pc` is located in a non-standard directory, which
can cause building the plugin to fail when building Netdata from source. In that case you
should find the file and link it to the standard pkg-config directory. Usually, running `sudo ln -s
/usr/lib/$(uname -m)-linux-gnu/pkgconfig/libipmimonitoring.pc/libipmimonitoring.pc /usr/lib/pkgconfig/libipmimonitoring.pc`
resolves this issue.
## Netdata use
The plugin creates (up to) 8 charts, based on the information collected from IPMI:
1. number of sensors by state
2. number of events in SEL
3. Temperatures CELSIUS
4. Temperatures FAHRENHEIT
5. Voltages
6. Currents
7. Power
8. Fans
It also adds 2 alarms:
1. Sensors in non-nominal state (i.e. warning and critical)
2. SEL is non empty
![image](https://cloud.githubusercontent.com/assets/2662304/23674138/88926a20-037d-11e7-89c0-20e74ee10cd1.png)
The plugin does a speed test when it starts, to find out the duration needed by the IPMI processor to respond. Depending on the speed of your IPMI processor, charts may need several seconds to show up on the dashboard.
## `freeipmi.plugin` configuration
The plugin supports a few options. To see them, run:
```text
# /usr/libexec/netdata/plugins.d/freeipmi.plugin -h
netdata freeipmi.plugin 1.8.0-546-g72ce5d6b_rolling
Copyright (C) 2016-2017 Costa Tsaousis <costa@tsaousis.gr>
Released under GNU General Public License v3 or later.
All rights reserved.
This program is a data collector plugin for netdata.
Available command line options:
SECONDS data collection frequency
minimum: 5
debug enable verbose output
default: disabled
sel
no-sel enable/disable SEL collection
default: enabled
hostname HOST
username USER
password PASS connect to remote IPMI host
default: local IPMI processor
noauthcodecheck don't check the authentication codes returned
driver-type IPMIDRIVER
Specify the driver type to use instead of doing an auto selection.
The currently available outofband drivers are LAN and LAN_2_0,
which perform IPMI 1.5 and IPMI 2.0 respectively.
The currently available inband drivers are KCS, SSIF, OPENIPMI and SUNBMC.
sdr-cache-dir PATH directory for SDR cache files
default: /tmp
sensor-config-file FILE filename to read sensor configuration
default: system default
ignore N1,N2,N3,... sensor IDs to ignore
default: none
-v
-V
version print version and exit
Linux kernel module for IPMI is CPU hungry.
On Linux run this to lower kipmiN CPU utilization:
# echo 10 > /sys/module/ipmi_si/parameters/kipmid_max_busy_us
or create: /etc/modprobe.d/ipmi.conf with these contents:
options ipmi_si kipmid_max_busy_us=10
For more information:
https://github.com/netdata/netdata/tree/master/collectors/freeipmi.plugin
```
You can set these options in `/etc/netdata/netdata.conf` at this section:
```
[plugin:freeipmi]
update every = 5
command options =
```
Append to `command options =` the settings you need. The minimum `update every` is 5 (enforced internally by the plugin). IPMI is slow and CPU hungry. So, once every 5 seconds is pretty acceptable.
## Ignoring specific sensors
Specific sensor IDs can be excluded from freeipmi tools by editing `/etc/freeipmi/freeipmi.conf` and setting the IDs to be ignored at `ipmi-sensors-exclude-record-ids`. **However this file is not used by `libipmimonitoring`** (the library used by Netdata's `freeipmi.plugin`).
So, `freeipmi.plugin` supports the option `ignore` that accepts a comma separated list of sensor IDs to ignore. To configure it, edit `/etc/netdata/netdata.conf` and set:
```
[plugin:freeipmi]
command options = ignore 1,2,3,4,...
```
To find the IDs to ignore, run the command `ipmimonitoring`. The first column is the wanted ID:
```
ID | Name | Type | State | Reading | Units | Event
1 | Ambient Temp | Temperature | Nominal | 26.00 | C | 'OK'
2 | Altitude | Other Units Based Sensor | Nominal | 480.00 | ft | 'OK'
3 | Avg Power | Current | Nominal | 100.00 | W | 'OK'
4 | Planar 3.3V | Voltage | Nominal | 3.29 | V | 'OK'
5 | Planar 5V | Voltage | Nominal | 4.90 | V | 'OK'
6 | Planar 12V | Voltage | Nominal | 11.99 | V | 'OK'
7 | Planar VBAT | Voltage | Nominal | 2.95 | V | 'OK'
8 | Fan 1A Tach | Fan | Nominal | 3132.00 | RPM | 'OK'
9 | Fan 1B Tach | Fan | Nominal | 2150.00 | RPM | 'OK'
10 | Fan 2A Tach | Fan | Nominal | 2494.00 | RPM | 'OK'
11 | Fan 2B Tach | Fan | Nominal | 1825.00 | RPM | 'OK'
12 | Fan 3A Tach | Fan | Nominal | 3538.00 | RPM | 'OK'
13 | Fan 3B Tach | Fan | Nominal | 2625.00 | RPM | 'OK'
14 | Fan 1 | Entity Presence | Nominal | N/A | N/A | 'Entity Present'
15 | Fan 2 | Entity Presence | Nominal | N/A | N/A | 'Entity Present'
...
```
## Debugging
You can run the plugin by hand:
```sh
# become user netdata
sudo su -s /bin/sh netdata
# run the plugin in debug mode
/usr/libexec/netdata/plugins.d/freeipmi.plugin 5 debug
```
You will get verbose output on what the plugin does.
## kipmi0 CPU usage
There have been reports that kipmi is showing increased CPU when the IPMI is queried. To lower the CPU consumption of
the system you can issue this command:
```sh
echo 10 > /sys/module/ipmi_si/parameters/kipmid_max_busy_us
```
You can also permanently set the above setting by creating the file `/etc/modprobe.d/ipmi.conf` with this content:
```sh
# prevent kipmi from consuming 100% CPU
options ipmi_si kipmid_max_busy_us=10
```
This instructs the kernel IPMI module to pause for a tick between checking IPMI. Querying IPMI will be a lot slower now (e.g. several seconds for IPMI to respond), but `kipmi` will not use any noticeable CPU. You can also use a higher number (this is the number of microseconds to poll IPMI for a response, before waiting for a tick).
If you need to disable IPMI for Netdata, edit `/etc/netdata/netdata.conf` and set:
```
[plugins]
freeipmi = no
```
|