summaryrefslogtreecommitdiffstats
path: root/collectors/python.d.plugin/sensors/integrations/linux_sensors_lm-sensors.md
blob: c807d6b3e24236c654e508723ccfae6b8d1d6330 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
<!--startmeta
custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/python.d.plugin/sensors/README.md"
meta_yaml: "https://github.com/netdata/netdata/edit/master/collectors/python.d.plugin/sensors/metadata.yaml"
sidebar_label: "Linux Sensors (lm-sensors)"
learn_status: "Published"
learn_rel_path: "Data Collection/Hardware Devices and Sensors"
message: "DO NOT EDIT THIS FILE DIRECTLY, IT IS GENERATED BY THE COLLECTOR'S metadata.yaml FILE"
endmeta-->

# Linux Sensors (lm-sensors)


<img src="https://netdata.cloud/img/microchip.svg" width="150"/>


Plugin: python.d.plugin
Module: sensors

<img src="https://img.shields.io/badge/maintained%20by-Netdata-%2300ab44" />

## Overview

Examine Linux Sensors metrics with Netdata for insights into hardware health and performance.

Enhance your system's reliability with real-time hardware health insights.


Reads system sensors information (temperature, voltage, electric current, power, etc.) via [lm-sensors](https://hwmon.wiki.kernel.org/lm_sensors).


This collector is supported on all platforms.

This collector supports collecting metrics from multiple instances of this integration, including remote instances.


### Default Behavior

#### Auto-Detection

The following type of sensors are auto-detected:
- temperature - fan - voltage - current - power - energy - humidity


#### Limits

The default configuration for this integration does not impose any limits on data collection.

#### Performance Impact

The default configuration for this integration is not expected to impose a significant performance impact on the system.


## Metrics

Metrics grouped by *scope*.

The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.



### Per chip

Metrics related to chips. Each chip provides a set of the following metrics, each having the chip name in the metric name as reported by `sensors -u`.


This scope has no labels.

Metrics:

| Metric | Dimensions | Unit |
|:------|:----------|:----|
| sensors.temperature | a dimension per sensor | Celsius |
| sensors.voltage | a dimension per sensor | Volts |
| sensors.current | a dimension per sensor | Ampere |
| sensors.power | a dimension per sensor | Watt |
| sensors.fan | a dimension per sensor | Rotations/min |
| sensors.energy | a dimension per sensor | Joule |
| sensors.humidity | a dimension per sensor | Percent |



## Alerts

There are no alerts configured by default for this integration.


## Setup

### Prerequisites

No action required.

### Configuration

#### File

The configuration file name for this integration is `python.d/sensors.conf`.


You can edit the configuration file using the `edit-config` script from the
Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md#the-netdata-config-directory).

```bash
cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config python.d/sensors.conf
```
#### Options

There are 2 sections:

* Global variables
* One or more JOBS that can define multiple different instances to monitor.

The following options can be defined globally: priority, penalty, autodetection_retry, update_every, but can also be defined per JOB to override the global values.

Additionally, the following collapsed table contains all the options that can be configured inside a JOB definition.

Every configuration JOB starts with a `job_name` value which will appear in the dashboard, unless a `name` parameter is specified.


<details><summary>Config options</summary>

| Name | Description | Default | Required |
|:----|:-----------|:-------|:--------:|
| types | The types of sensors to collect. | temperature, fan, voltage, current, power, energy, humidity | True |
| update_every | Sets the default data collection frequency. | 1 | False |
| priority | Controls the order of charts at the netdata dashboard. | 60000 | False |
| autodetection_retry | Sets the job re-check interval in seconds. | 0 | False |
| penalty | Indicates whether to apply penalty to update_every in case of failures. | yes | False |

</details>

#### Examples

##### Default

Default configuration.

```yaml
types:
  - temperature
  - fan
  - voltage
  - current
  - power
  - energy
  - humidity

```


## Troubleshooting

### Debug Mode

To troubleshoot issues with the `sensors` collector, run the `python.d.plugin` with the debug option enabled. The output
should give you clues as to why the collector isn't working.

- Navigate to the `plugins.d` directory, usually at `/usr/libexec/netdata/plugins.d/`. If that's not the case on
  your system, open `netdata.conf` and look for the `plugins` setting under `[directories]`.

  ```bash
  cd /usr/libexec/netdata/plugins.d/
  ```

- Switch to the `netdata` user.

  ```bash
  sudo -u netdata -s
  ```

- Run the `python.d.plugin` to debug the collector:

  ```bash
  ./python.d.plugin sensors debug trace
  ```

### lm-sensors doesn't work on your device



### ACPI ring buffer errors are printed