1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
|
<!--
title: "Common configuration changes"
description: "See the most popular configuration changes to make to the Netdata Agent, including longer metrics retention, reduce sampling, and more."
custom_edit_url: "https://github.com/netdata/netdata/edit/master/docs/configure/common-changes.md"
sidebar_label: "Common configuration changes"
learn_status: "Published"
learn_topic_type: "Tasks"
learn_rel_path: "Configuration"
-->
# Common configuration changes
The Netdata Agent requires no configuration upon installation to collect thousands of per-second metrics from most
systems, containers, and applications, but there are hundreds of settings to tweak if you want to exercise more control
over your monitoring platform.
This document assumes familiarity with
using [`edit-config`](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md) from the Netdata config
directory.
## Change dashboards and visualizations
The Netdata Agent's [local dashboard](https://github.com/netdata/netdata/blob/master/docs/category-overview-pages/accessing-netdata-dashboards.md), accessible
at `http://NODE:19999` is highly configurable. If
you use Netdata Cloud
for [infrastructure monitoring](https://github.com/netdata/netdata/blob/master/docs/quickstart/infrastructure.md), you
will see many of these
changes reflected in those visualizations due to the way Netdata Cloud proxies metric data and metadata to your browser.
### Increase the long-term metrics retention period
Read our doc
on [increasing long-term metrics storage](https://github.com/netdata/netdata/blob/master/docs/store/change-metrics-storage.md)
for details, including a
[calculator](https://github.com/netdata/netdata/blob/master/docs/store/change-metrics-storage.md#calculate-the-system-resources-ram-disk-space-needed-to-store-metrics)
to help you determine the exact settings for your desired retention period.
### Reduce the data collection frequency
Change `update every` in
the [`[global]` section](https://github.com/netdata/netdata/blob/master/daemon/config/README.md#global-section-options)
of `netdata.conf` so
that it is greater than `1`. An `update every` of `5` means the Netdata Agent enforces a _minimum_ collection frequency
of 5 seconds.
```conf
[global]
update every = 5
```
Every collector and plugin has its own `update every` setting, which you can also change in the `go.d.conf`,
`python.d.conf` or `charts.d.conf` files, or in individual collector configuration files. If the `update
every` for an individual collector is less than the global, the Netdata Agent uses the global setting. See
the [enable or configure a collector](https://github.com/netdata/netdata/blob/master/collectors/REFERENCE.md#enable-and-disable-a-specific-collection-module)
doc for details.
### Disable a collector or plugin
Turn off entire plugins in
the [`[plugins]` section](https://github.com/netdata/netdata/blob/master/daemon/config/README.md#plugins-section-options)
of
`netdata.conf`.
To disable specific collectors, open `go.d.conf`, `python.d.conf` or `charts.d.conf` and find the line
for that specific module. Uncomment the line and change its value to `no`.
## Modify alerts and notifications
Netdata's health monitoring watchdog uses hundreds of preconfigured health entities, with intelligent thresholds, to
generate warning and critical alerts for most production systems and their applications without configuration. However,
each alert and notification method is completely customizable.
### Add a new alert
To create a new alert configuration file, initiate an empty file, with a filename that ends in `.conf`, in the
`health.d/` directory. The Netdata Agent loads any valid alert configuration file ending in `.conf` in that directory.
Next, edit the new file with `edit-config`. For example, with a file called `example-alert.conf`.
```bash
sudo touch health.d/example-alert.conf
sudo ./edit-config health.d/example-alert.conf
```
Or, append your new alert to an existing file by editing a relevant existing file in the `health.d/` directory.
Read more about [configuring alerts](https://github.com/netdata/netdata/blob/master/health/REFERENCE.md) to
get started, and see
the [health monitoring reference](https://github.com/netdata/netdata/blob/master/health/REFERENCE.md) for a full listing
of options available in health entities.
### Configure a specific alert
Tweak existing alerts by editing files in the `health.d/` directory. For example, edit `health.d/cpu.conf` to change how
the Agent responds to anomalies related to CPU utilization.
To see which configuration file you need to edit to configure a specific
alert, [view your active alerts](https://github.com/netdata/netdata/blob/master/docs/monitor/view-active-alerts.md) in
Netdata Cloud or the local Agent dashboard and look for the **source** line. For example, it might
read `source 4@/usr/lib/netdata/conf.d/health.d/cpu.conf`.
Because the source path contains `health.d/cpu.conf`, run `sudo edit-config health.d/cpu.conf` to configure that alert.
### Disable a specific alert
Open the configuration file for that alert and set the `to` line to `silent`.
```conf
template: disk_fill_rate
on: disk.space
lookup: max -1s at -30m unaligned of avail
calc: ($this - $avail) / (30 * 60)
every: 15s
to: silent
```
### Turn of all alerts and notifications
Set `enabled` to `no` in
the [`[health]`](https://github.com/netdata/netdata/blob/master/daemon/config/README.md#health-section-options)
section of `netdata.conf`.
### Enable alert notifications
Open `health_alarm_notify.conf` for editing. First, read the [enabling
notifications](https://github.com/netdata/netdata/blob/master/docs/monitor/enable-notifications.md#netdata-agent) doc
for an example of the process using Slack, then
click on the link to your preferred notification method to find documentation for that specific endpoint.
## Improve node security
While the Netdata Agent is both [open and secure by design](https://www.netdata.cloud/blog/netdata-agent-dashboard/), we
recommend every user take some action to administer and secure their nodes.
Learn more about the available options in the [security design documentation](https://github.com/netdata/netdata/blob/master/docs/netdata-security.md).
## Reduce resource usage
Read
our [performance optimization guide](https://github.com/netdata/netdata/blob/master/docs/guides/configure/performance.md)
for a long list of specific changes
that can reduce the Netdata Agent's CPU/memory footprint and IO requirements.
## Organize nodes with host labels
Beginning with v1.20, Netdata accepts user-defined **host labels**. These labels are sent during streaming, exporting,
and as metadata to Netdata Cloud, and help you organize the metrics coming from complex infrastructure. Host labels are
defined in the section `[host labels]`.
For a quick introduction, read
the [host label guide](https://github.com/netdata/netdata/blob/master/docs/guides/using-host-labels.md).
The following restrictions apply to host label names:
- Names cannot start with `_`, but it can be present in other parts of the name.
- Names only accept alphabet letters, numbers, dots, and dashes.
The policy for values is more flexible, but you can not use exclamation marks (`!`), whitespaces (` `), single quotes
(`'`), double quotes (`"`), or asterisks (`*`), because they are used to compare label values in health alerts and
templates.
|