diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2023-12-24 07:57:49 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2023-12-24 07:57:49 +0000 |
commit | fc67d3ad9a2903cc33e5cdaedaad51dd86a42236 (patch) | |
tree | 4ef72536a965fe220e71aea78b76b6bbbac2ed59 /Documentation/nvme-virtium-save-smart-to-vtview-log.html | |
parent | Adding upstream version 2.5. (diff) | |
download | nvme-cli-fc67d3ad9a2903cc33e5cdaedaad51dd86a42236.tar.xz nvme-cli-fc67d3ad9a2903cc33e5cdaedaad51dd86a42236.zip |
Adding upstream version 2.7.1.upstream/2.7.1
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/nvme-virtium-save-smart-to-vtview-log.html')
-rw-r--r-- | Documentation/nvme-virtium-save-smart-to-vtview-log.html | 36 |
1 files changed, 19 insertions, 17 deletions
diff --git a/Documentation/nvme-virtium-save-smart-to-vtview-log.html b/Documentation/nvme-virtium-save-smart-to-vtview-log.html index 7140680..4f84716 100644 --- a/Documentation/nvme-virtium-save-smart-to-vtview-log.html +++ b/Documentation/nvme-virtium-save-smart-to-vtview-log.html @@ -763,18 +763,19 @@ nvme-virtium-save-smart-to-vtview-log(1) Manual Page <div class="paragraph"><p>This command automates the process of collecting SMART data periodically and
saving the data in a ready-to-analyze format. Each entry is saved
with timestamp and in csv format. Users can use excel to analyze the data.
-Some examples of use cases are collecting SMART data for temperature characterization,
-collecting data to calculate endurance, or collecting SMART data during a test
-or during normal operation.</p></div>
+Some examples of use cases are collecting SMART data for temperature
+characterization, data to calculate endurance, or collecting SMART data during a
+test or during normal operation.</p></div>
<div class="paragraph"><p>The <device> parameter is mandatory and may be either the NVMe character
device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).</p></div>
-<div class="paragraph"><p>On success, the command generates a log file, which contains an entry for identify device
-(current features & settings) and periodic entries of SMART data.</p></div>
-<div class="paragraph"><p>This command runs for the time specified by the option <run-time>, and collects SMART data
-at the frequency specified by the option <freq>. If the output file name is not specified,
-this command will generate a file name that include model string and serial number of the device.</p></div>
-<div class="paragraph"><p>If the test-name option is specified, it will be recorded in the log file and be used as part
-of the log file name.</p></div>
+<div class="paragraph"><p>On success, the command generates a log file, which contains an entry for
+identify device (current features & settings) and periodic entries of SMART data.</p></div>
+<div class="paragraph"><p>This command runs for the time specified by the option <run-time>, and collects
+SMART data at the frequency specified by the option <freq>. If the output file
+name is not specified, this command will generate a file name that include model
+string and serial number of the device.</p></div>
+<div class="paragraph"><p>If the test-name option is specified, it will be recorded in the log file and be
+used as part of the log file name.</p></div>
</div>
</div>
<div class="sect1">
@@ -800,8 +801,8 @@ of the log file name.</p></div> </dt>
<dd>
<p>
- (optional) How often you want to log SMART data
- (0.25 = 15' , 0.5 = 30' , 1 = 1 hour, 2 = 2 hours, etc.). Default = 10 hours.
+ (optional) How often you want to log SMART data (0.25 = 15', 0.5 = 30',
+ 1 = 1 hour, 2 = 2 hours, etc.). Default = 10 hours.
</p>
</dd>
<dt class="hdlist1">
@@ -812,9 +813,9 @@ of the log file name.</p></div> </dt>
<dd>
<p>
- (optional) Name of the log file (give it a name that easy for you to remember
- what the test is). You can leave it blank too, the file name will be generated
- as <model string>-<serial number>-<test name>.txt.
+ (optional) Name of the log file (give it a name that easy for you to
+ remember what the test is). You can leave it blank too, the file name
+ will be generated as <model string>-<serial number>-<test name>.txt.
</p>
</dd>
<dt class="hdlist1">
@@ -825,7 +826,8 @@ of the log file name.</p></div> </dt>
<dd>
<p>
- (optional) Name of the test you are doing. We use this string as part of the name of the log file.
+ (optional) Name of the test you are doing. We use this string as part of
+ the name of the log file.
</p>
</dd>
</dl></div>
@@ -876,7 +878,7 @@ Just logging: Default logging is run for 20 hours and log every 10 hours. <div id="footer">
<div id="footer-text">
Last updated
- 2023-06-30 15:20:22 CEST
+ 2023-12-21 15:49:29 CET
</div>
</div>
</body>
|