summaryrefslogtreecommitdiffstats
path: root/Documentation/nvme-zns-zone-mgmt-send.1
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2021-07-02 20:49:35 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2021-07-02 20:49:35 +0000
commitf2c543b4ccad3b9f8871d952cddf66b3b438595b (patch)
treec3c363d1cc72514221685c42a79a19b320114acc /Documentation/nvme-zns-zone-mgmt-send.1
parentAdding debian version 1.12-8. (diff)
downloadnvme-cli-f2c543b4ccad3b9f8871d952cddf66b3b438595b.tar.xz
nvme-cli-f2c543b4ccad3b9f8871d952cddf66b3b438595b.zip
Merging upstream version 1.14.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to '')
-rw-r--r--Documentation/nvme-zns-zone-mgmt-send.1126
1 files changed, 126 insertions, 0 deletions
diff --git a/Documentation/nvme-zns-zone-mgmt-send.1 b/Documentation/nvme-zns-zone-mgmt-send.1
new file mode 100644
index 0000000..f74d8a3
--- /dev/null
+++ b/Documentation/nvme-zns-zone-mgmt-send.1
@@ -0,0 +1,126 @@
+'\" t
+.\" Title: nvme-zns-zone-mgmt-send
+.\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author]
+.\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/>
+.\" Date: 10/20/2020
+.\" Manual: NVMe Manual
+.\" Source: NVMe
+.\" Language: English
+.\"
+.TH "NVME\-ZNS\-ZONE\-MGM" "1" "10/20/2020" "NVMe" "NVMe Manual"
+.\" -----------------------------------------------------------------
+.\" * Define some portability stuff
+.\" -----------------------------------------------------------------
+.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+.\" http://bugs.debian.org/507673
+.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
+.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+.ie \n(.g .ds Aq \(aq
+.el .ds Aq '
+.\" -----------------------------------------------------------------
+.\" * set default formatting
+.\" -----------------------------------------------------------------
+.\" disable hyphenation
+.nh
+.\" disable justification (adjust text to left margin only)
+.ad l
+.\" -----------------------------------------------------------------
+.\" * MAIN CONTENT STARTS HERE *
+.\" -----------------------------------------------------------------
+.SH "NAME"
+nvme-zns-zone-mgmt-send \- Zone Management Send command
+.SH "SYNOPSIS"
+.sp
+.nf
+\fInvme zns zone\-mgmt\-send\fR <device> [\-\-namespace\-id=<NUM> | \-n <NUM>]
+ [\-\-start\-lba=<IONUM>, \-s <IONUM>]
+ [\-\-select\-all, \-a]
+ [\-\-zsa=<NUM>, \-z <NUM>]
+ [\-\-data\-len=<IONUM>, \-l <IONUM>]
+ [\-data=<FILE>, \-d <FILE>]
+.fi
+.SH "DESCRIPTION"
+.sp
+For the NVMe device given, issues the Zone Management Send command with the requested send action\&. If the send requires additional data, you may specify the data length\&. If data is required, the input will default to stdin\&. Alternatively, the data may come from a file that can be specified\&.
+.SH "OPTIONS"
+.PP
+\-n <NUM>, \-\-namespace\-id=<NUM>
+.RS 4
+Use the provided namespace id for the command\&. If not provided, the namespace id of the block device will be used\&. If the command is issued to a non\-block device, the parameter is required\&.
+.RE
+.PP
+\-s <lba>, \-\-start\-lba=<lba>
+.RS 4
+The starting LBA of the zone to manage send\&.
+.RE
+.PP
+\-l <NUM>, \-\-data\-len=<NUM>
+.RS 4
+Send data buffer length
+.RE
+.PP
+\-\-select\-all, \-a
+.RS 4
+Send command to all zones
+.RE
+.PP
+\-z <NUM>, \-\-zsa=<NUM>
+.RS 4
+Zone send action\&.
+.RE
+.PP
+\-l <IONUM>, \-\-data\-len=<IONUM>
+.RS 4
+Buffer length if data required
+.RE
+.PP
+\-d <FILE, \-data=<FILE>
+.RS 4
+Optional file for data (default stdin)
+.RE
+.SH "EXAMPLES"
+.sp
+.RS 4
+.ie n \{\
+\h'-04'\(bu\h'+03'\c
+.\}
+.el \{\
+.sp -1
+.IP \(bu 2.3
+.\}
+Send a zone management command with action set to 1 (close zone) to namespace 1\(cqs first zone:
+.sp
+.if n \{\
+.RS 4
+.\}
+.nf
+# nvme zns zone\-mgmt\-send /dev/nvme0 \-n 1 \-s 0 \-z 1
+.fi
+.if n \{\
+.RE
+.\}
+.RE
+.sp
+.RS 4
+.ie n \{\
+\h'-04'\(bu\h'+03'\c
+.\}
+.el \{\
+.sp -1
+.IP \(bu 2.3
+.\}
+Write "hello world" into the zone descriptor for namespace 1\(cqs first zone (requires device supports a large enough zone extended data)
+.sp
+.if n \{\
+.RS 4
+.\}
+.nf
+# echo "hello world" | nvme zns zone\-mgmt\-send /dev/nvme0 \-n 1 \-s 0 \-z 0x10
+.fi
+.if n \{\
+.RE
+.\}
+.RE
+.SH "NVME"
+.sp
+Part of nvme\-cli