summaryrefslogtreecommitdiffstats
path: root/Documentation/nvme.1
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2022-07-14 18:28:04 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2022-07-16 15:12:07 +0000
commit589986012c4b3ab68e299a2eadca18f90080113b (patch)
treef29a53b04a1950cdddae69344bccb3f0146fa728 /Documentation/nvme.1
parentReleasing debian version 1.16-4. (diff)
downloadnvme-cli-589986012c4b3ab68e299a2eadca18f90080113b.tar.xz
nvme-cli-589986012c4b3ab68e299a2eadca18f90080113b.zip
Merging upstream version 2.0.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/nvme.1')
-rw-r--r--Documentation/nvme.1512
1 files changed, 509 insertions, 3 deletions
diff --git a/Documentation/nvme.1 b/Documentation/nvme.1
index f1593d9..6162752 100644
--- a/Documentation/nvme.1
+++ b/Documentation/nvme.1
@@ -2,12 +2,12 @@
.\" Title: nvme
.\" Author: [see the "Authors" section]
.\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/>
-.\" Date: 11/11/2021
+.\" Date: 04/08/2022
.\" Manual: NVMe Manual
.\" Source: NVMe
.\" Language: English
.\"
-.TH "NVME" "1" "11/11/2021" "NVMe" "NVMe Manual"
+.TH "NVME" "1" "04/08/2022" "NVMe" "NVMe Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
@@ -73,7 +73,7 @@ Retrieve error logs
Submit flush
.RE
.PP
-\fBnvme-dms\fR(1)
+\fBnvme-dsm\fR(1)
.RS 4
Submit Data Set Management
.RE
@@ -323,6 +323,11 @@ Discover and connect to all NVMe\-over\-Fabrics subsystems
Connect to an NVMe\-over\-Fabrics subsystem
.RE
.PP
+\fBnvme-dim\fR(1)
+.RS 4
+Send Discovery Information Management command to a Discovery Controller
+.RE
+.PP
\fBnvme-disconnect\fR(1)
.RS 4
Disconnect from an NVMe\-over\-Fabrics subsystem
@@ -337,6 +342,507 @@ Disconnect from all NVMe\-over\-Fabrics subsystems
.RS 4
Reads and shows NVMe\-over\-Fabrics controller property
.RE
+.PP
+\fBnvme-media-unit-stat-log\fR(1)
+.RS 4
+Retrieve and show the configuration and wear of media units
+.RE
+.PP
+\fBnvme-supported-cap-config-log\fR(1)
+.RS 4
+Retrieve and show the list of Supported Capacity Configuration Descriptors
+.RE
+.PP
+\fBnvme-boot-part-log\fR(1)
+.RS 4
+Retrieve Boot Partition Log
+.RE
+.PP
+\fBnvme-capacity-mgmt\fR(1)
+.RS 4
+Capacity Management Command
+.RE
+.PP
+\fBnvme-check-dhchap-key\fR(1)
+.RS 4
+Generate NVMeoF DH\-HMAC\-CHAP host key
+.RE
+.PP
+\fBnvme-check-tls-key\fR(1)
+.RS 4
+Validate NVMeoF TLS PSK
+.RE
+.PP
+\fBnvme-cmdset-ind-id-ns\fR(1)
+.RS 4
+I/O Command Set Independent Identify Namespace
+.RE
+.PP
+\fBnvme-endurance-event-agg-log\fR(1)
+.RS 4
+Retrieve Endurance Group Event Aggregate Log
+.RE
+.PP
+\fBnvme-fid-support-effects-log\fR(1)
+.RS 4
+Retrieve FID Support and Effects log
+.RE
+.PP
+\fBnvme-gen-dhchap-key\fR(1)
+.RS 4
+Generate NVMeoF DH\-HMAC\-CHAP host key
+.RE
+.PP
+\fBnvme-gen-hostnqn\fR(1)
+.RS 4
+Generate NVMeoF host NQN
+.RE
+.PP
+\fBnvme-gen-tls-key\fR(1)
+.RS 4
+Generate NVMeoF TLS PSK
+.RE
+.PP
+\fBnvme-get-lba-status\fR(1)
+.RS 4
+Get LBA Status command
+.RE
+.PP
+\fBnvme-id-domain\fR(1)
+.RS 4
+NVMe Identify Domain List
+.RE
+.PP
+\fBnvme-id-ns-lba-format\fR(1)
+.RS 4
+NVMe Identify Namespace for the specified LBA Format index
+.RE
+.PP
+\fBnvme-lba-status-log\fR(1)
+.RS 4
+Retrieve LBA Status Information Log
+.RE
+.PP
+\fBnvme-list-endgrp\fR(1)
+.RS 4
+NVMe Identify Endurance Group List
+.RE
+.PP
+\fBnvme-ns-rescan\fR(1)
+.RS 4
+Rescans the NVME namespaces
+.RE
+.PP
+\fBnvme-nvm-id-ctrl\fR(1)
+.RS 4
+NVMe Identify Controller NVM Command Set
+.RE
+.PP
+\fBnvme-nvm-id-ns\fR(1)
+.RS 4
+NVMe Identify Namespace NVM Command Set
+.RE
+.PP
+\fBnvme-nvm-id-ns-lba-format\fR(1)
+.RS 4
+NVMe Identify Namespace NVM Command Set for the specified LBA Format index
+.RE
+.PP
+\fBnvme-persistent-event-log\fR(1)
+.RS 4
+Retrieve Presistent Event Log
+.RE
+.PP
+\fBnvme-predictable-lat-log\fR(1)
+.RS 4
+Retrieve Predictable Latency per Nvmset Log
+.RE
+.PP
+\fBnvme-pred-lat-event-agg-log\fR(1)
+.RS 4
+Retrieve Predictable Latency Event Aggregate Log
+.RE
+.PP
+\fBnvme-primary-ctrl-caps\fR(1)
+.RS 4
+NVMe Identify Primary Controller Capabilities
+.RE
+.PP
+\fBnvme-reset\fR(1)
+.RS 4
+Resets the controller
+.RE
+.PP
+\fBnvme-rpmb\fR(1)
+.RS 4
+Replay Protection Memory Block commands
+.RE
+.PP
+\fBnvme-sanitize-log\fR(1)
+.RS 4
+Retrieve sanitize log
+.RE
+.PP
+\fBnvme-set-property\fR(1)
+.RS 4
+Set a property and show the resulting value
+.RE
+.PP
+\fBnvme-show-hostnqn\fR(1)
+.RS 4
+Show NVMeoF host NQN
+.RE
+.PP
+\fBnvme-subsystem-reset\fR(1)
+.RS 4
+Resets the subsystem
+.RE
+.PP
+\fBnvme-supported-log-pages\fR(1)
+.RS 4
+Retrieve the Supported Log pages details
+.RE
+.PP
+\fBnvme-verify\fR(1)
+.RS 4
+verify command
+.RE
+.SS "Plugins/Vendor extension commands"
+.PP
+\fBnvme-intel-id-ctrl\fR(1)
+.RS 4
+Intel \- NVMe Identify Controller
+.RE
+.PP
+\fBnvme-intel-internal-log\fR(1)
+.RS 4
+Retrieve Intel device\(cqs internal log and save to file
+.RE
+.PP
+\fBnvme-intel-lat-stats\fR(1)
+.RS 4
+Retrieve NVMe Identify Controller, return result and structure
+.RE
+.PP
+\fBnvme-intel-market-name\fR(1)
+.RS 4
+Intel vendor specific marketing name log page
+.RE
+.PP
+\fBnvme-intel-smart-log-add\fR(1)
+.RS 4
+NVMe Intel Additional SMART log page
+.RE
+.PP
+\fBnvme-intel-temp-stats\fR(1)
+.RS 4
+NVMe Intel Additional SMART log page for temp stats
+.RE
+.PP
+\fBnvme-huawei-id-ctrl\fR(1)
+.RS 4
+NVMe huawei Identify Controller
+.RE
+.PP
+\fBnvme-huawei-list\fR(1)
+.RS 4
+List all recognized Huawei NVMe devices
+.RE
+.PP
+\fBnvme-dera-stat\fR(1)
+.RS 4
+NVMe Dera Device status and Additional SMART log page request
+.RE
+.PP
+\fBnvme-micron-clear-pcie-errors\fR(1)
+.RS 4
+Clears correctable PCIe correctable errors of given Micron device
+.RE
+.PP
+\fBnvme-micron-internal-log\fR(1)
+.RS 4
+Retrieve Micron device\(cqs internal logs and save to given zip file
+.RE
+.PP
+\fBnvme-micron-nand-stats\fR(1)
+.RS 4
+Retrieves NAND statistics of given micron device
+.RE
+.PP
+\fBnvme-micron-pcie-stats\fR(1)
+.RS 4
+Retrieves pcie error statistics for given micron device
+.RE
+.PP
+\fBnvme-micron-selective-download\fR(1)
+.RS 4
+Performs selective firmware download
+.RE
+.PP
+\fBnvme-micron-smart-add-log\fR(1)
+.RS 4
+Retrieves NAND statistics
+.RE
+.PP
+\fBnvme-micron-temperature-stats\fR(1)
+.RS 4
+Retrieves temperature information of given micron device
+.RE
+.PP
+\fBnvme-netapp-ontapdevices\fR(1)
+.RS 4
+Display information about ONTAP devices
+.RE
+.PP
+\fBnvme-netapp-smdevices\fR(1)
+.RS 4
+Display information for each NVMe path to an E\-Series volume
+.RE
+.PP
+\fBnvme-toshiba-clear-pcie-correctable-errors\fR(1)
+.RS 4
+Reset the PCIe correctable errors count to zero
+.RE
+.PP
+\fBnvme-toshiba-vs-internal-log\fR(1)
+.RS 4
+Retrieve a Toshiba device\(cqs vendor specific internal log
+.RE
+.PP
+\fBnvme-toshiba-vs-smart-add-log\fR(1)
+.RS 4
+Retrieve a Toshiba device\(cqs vendor specific extended SMART log page
+.RE
+.PP
+\fBnvme-transcend-badblock\fR(1)
+.RS 4
+Retrieve Transcend NVMe device\(cqs bad blocks
+.RE
+.PP
+\fBnvme-transcend-healthvalue\fR(1)
+.RS 4
+Use NVMe SMART table to analyse the health value of Transcend device
+.RE
+.PP
+\fBnvme-virtium-show-identify\fR(1)
+.RS 4
+Show a complete detail of identify device information in json format
+.RE
+.PP
+\fBnvme-virtium-save-smart-to-vtview-log\fR(1)
+.RS 4
+Periodically save smart attributes into a log file
+.RE
+.PP
+\fBnvme-wdc-cap-diag\fR(1)
+.RS 4
+Retrieve WDC device\(cqs diagnostic log and save to file
+.RE
+.PP
+\fBnvme-wdc-capabilities\fR(1)
+.RS 4
+Display WDC plugin command capabilities
+.RE
+.PP
+\fBnvme-wdc-clear-assert-dump\fR(1)
+.RS 4
+Clears the assert dump (if present)
+.RE
+.PP
+\fBnvme-wdc-clear-fw-activate-history\fR(1)
+.RS 4
+Clears the firmware activate history table
+.RE
+.PP
+\fBnvme-wdc-clear-pcie-corr\fR(1)
+.RS 4
+Clears the pcie correctable errors field
+.RE
+.PP
+\fBnvme-wdc-clear-pcie-correctable-errors\fR(1)
+.RS 4
+Clears the pcie correctable errors returned in the smart\-log\-add command
+.RE
+.PP
+\fBnvme-wdc-cloud-SSD-plugin-version\fR(1)
+.RS 4
+Display WDC plugin Cloud SSD Plugin Version
+.RE
+.PP
+\fBnvme-wdc-drive-essentials\fR(1)
+.RS 4
+Retrieve WDC device\(cqs drive essentials bin files
+.RE
+.PP
+\fBnvme-wdc-drive-log\fR(1)
+.RS 4
+Retrieve WDC device\(cqs drive log and save to file
+.RE
+.PP
+\fBnvme-wdc-drive-resize\fR(1)
+.RS 4
+Send NVMe WDC Resize Vendor Unique Command
+.RE
+.PP
+\fBnvme-wdc-enc-get-log\fR(1)
+.RS 4
+Send NVMe WDC enc\-get\-log Vendor Unique Command
+.RE
+.PP
+\fBnvme-wdc-get-crash-dump\fR(1)
+.RS 4
+Retrieve WDC device\(cqs crash dump
+.RE
+.PP
+\fBnvme-wdc-get-drive-status\fR(1)
+.RS 4
+Send the NVMe WDC get\-drive\-status command
+.RE
+.PP
+\fBnvme-wdc-get-latency-monitor-log\fR(1)
+.RS 4
+Display latency monitor log page data in human readable format
+.RE
+.PP
+\fBnvme-wdc-get-pfail-dump\fR(1)
+.RS 4
+Retrieve WDC device\(cqs pfail crash dump
+.RE
+.PP
+\fBnvme-wdc-id-ctrl\fR(1)
+.RS 4
+Send NVMe Identify Controller, return result and structure
+.RE
+.PP
+\fBnvme-wdc-log-page-directory\fR(1)
+.RS 4
+Retrieves the list of Log IDs supported by the drive
+.RE
+.PP
+\fBnvme-wdc-namespace-resize\fR(1)
+.RS 4
+Resizes the device\(cqs namespace
+.RE
+.PP
+\fBnvme-wdc-purge-monitor\fR(1)
+.RS 4
+Send NVMe WDC Purge\-Monitor Vendor Unique Command
+.RE
+.PP
+\fBnvme-wdc-purge\fR(1)
+.RS 4
+Send NVMe WDC Purge Vendor Unique Command
+.RE
+.PP
+\fBnvme-wdc-smart-add-log\fR(1)
+.RS 4
+Send NVMe WDC smart add log Vendor Unique Command
+.RE
+.PP
+\fBnvme-wdc-vs-drive-info\fR(1)
+.RS 4
+Send the NVMe WDC vs\-drive\-info command
+.RE
+.PP
+\fBnvme-wdc-vs-error-reason-identifier\fR(1)
+.RS 4
+Retrieve WDC device\(cqs telemetry log error reason identifier field
+.RE
+.PP
+\fBnvme-wdc-vs-fw-activate-history\fR(1)
+.RS 4
+Execute NVMe WDC vs\-fw\-activate\-history Vendor Unique Command
+.RE
+.PP
+\fBnvme-wdc-vs-internal-log\fR(1)
+.RS 4
+Retrieve WDC device\(cqs internal firmware log and save to file
+.RE
+.PP
+\fBnvme-wdc-vs-nand-stats\fR(1)
+.RS 4
+Send NVMe WDC vs\-nand\-stats Vendor Unique Command
+.RE
+.PP
+\fBnvme-wdc-vs-telemetry-controller-option\fR(1)
+.RS 4
+Disable/Enable the controller initiated option of the telemetry log page
+.RE
+.PP
+\fBnvme-wdc-vs-temperature-stats\fR(1)
+.RS 4
+Display temperature\-related statistics
+.RE
+.PP
+\fBnvme-zns-changed-zone-list\fR(1)
+.RS 4
+Retrieve Changed Zone log for the given device
+.RE
+.PP
+\fBnvme-zns-close-zone\fR(1)
+.RS 4
+Closes one or all zones
+.RE
+.PP
+\fBnvme-zns-finish-zone\fR(1)
+.RS 4
+Finishes one or all zones
+.RE
+.PP
+\fBnvme-zns-id-ctrl\fR(1)
+.RS 4
+Send NVMe Zoned Command Set Identify Controller
+.RE
+.PP
+\fBnvme-zns-id-ns\fR(1)
+.RS 4
+Send NVMe Zoned Command Set Identify Namespace
+.RE
+.PP
+\fBnvme-zns-offline-zone\fR(1)
+.RS 4
+Offlines one or all zones
+.RE
+.PP
+\fBnvme-zns-open-zone\fR(1)
+.RS 4
+Opens one or all zones
+.RE
+.PP
+\fBnvme-zns-report-zones\fR(1)
+.RS 4
+Retrieve and display the Report Zones data structure
+.RE
+.PP
+\fBnvme-zns-reset-zone\fR(1)
+.RS 4
+Resets one or all zones
+.RE
+.PP
+\fBnvme-zns-set-zone-desc\fR(1)
+.RS 4
+Set extended descriptor data for a zone
+.RE
+.PP
+\fBnvme-zns-zone-append\fR(1)
+.RS 4
+Send an NVMe write command, provide results
+.RE
+.PP
+\fBnvme-zns-zone-mgmt-recv\fR(1)
+.RS 4
+Zone Management Receive command
+.RE
+.PP
+\fBnvme-zns-zone-mgmt-send\fR(1)
+.RS 4
+Zone Management Send command
+.RE
+.PP
+\fBnvme-zns-zrwa-flush-zone\fR(1)
+.RS 4
+Flush LBAs associated with a ZRWA to a zone
+.RE
.SH "FURTHER DOCUMENTATION"
.sp
See the freely available references on the \m[blue]\fBOfficial NVM\-Express Site\fR\m[]\&\s-2\u[1]\d\s+2\&.