summaryrefslogtreecommitdiffstats
path: root/Documentation/nvme-id-iocs.1
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/nvme-id-iocs.1')
-rw-r--r--Documentation/nvme-id-iocs.172
1 files changed, 72 insertions, 0 deletions
diff --git a/Documentation/nvme-id-iocs.1 b/Documentation/nvme-id-iocs.1
new file mode 100644
index 0000000..f79b4de
--- /dev/null
+++ b/Documentation/nvme-id-iocs.1
@@ -0,0 +1,72 @@
+'\" t
+.\" Title: nvme-id-iocs
+.\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author]
+.\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/>
+.\" Date: 10/20/2020
+.\" Manual: NVMe Manual
+.\" Source: NVMe
+.\" Language: English
+.\"
+.TH "NVME\-ID\-IOCS" "1" "10/20/2020" "NVMe" "NVMe Manual"
+.\" -----------------------------------------------------------------
+.\" * Define some portability stuff
+.\" -----------------------------------------------------------------
+.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+.\" http://bugs.debian.org/507673
+.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
+.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+.ie \n(.g .ds Aq \(aq
+.el .ds Aq '
+.\" -----------------------------------------------------------------
+.\" * set default formatting
+.\" -----------------------------------------------------------------
+.\" disable hyphenation
+.nh
+.\" disable justification (adjust text to left margin only)
+.ad l
+.\" -----------------------------------------------------------------
+.\" * MAIN CONTENT STARTS HERE *
+.\" -----------------------------------------------------------------
+.SH "NAME"
+nvme-id-iocs \- Send NVMe Identify I/O Command Set, return result and structure
+.SH "SYNOPSIS"
+.sp
+.nf
+\fInvme id\-iocs\fR <device> [\-\-controller\-id=<cntid> | \-c <cntid>]
+.fi
+.SH "DESCRIPTION"
+.sp
+For the NVMe device given, send an identify command and return the Identify I/O Command Set data structure\&.
+.sp
+The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1)\&.
+.SH "OPTIONS"
+.PP
+\-c <cntid>, \-\-controller\-id=<cntid>
+.RS 4
+Retrieve the identify I/O Command set data structure for the given cntid\&. If this value is not given, cntid will be 0xffff\&.
+.RE
+.SH "EXAMPLES"
+.sp
+.RS 4
+.ie n \{\
+\h'-04'\(bu\h'+03'\c
+.\}
+.el \{\
+.sp -1
+.IP \(bu 2.3
+.\}
+Have the program interpret the returned buffer and display the known fields in a human readable format:
+.sp
+.if n \{\
+.RS 4
+.\}
+.nf
+# nvme id\-iocs /dev/nvme0
+.fi
+.if n \{\
+.RE
+.\}
+.RE
+.SH "NVME"
+.sp
+Part of the nvme\-user suite