diff options
Diffstat (limited to 'Documentation/nvme.1')
-rw-r--r-- | Documentation/nvme.1 | 512 |
1 files changed, 509 insertions, 3 deletions
diff --git a/Documentation/nvme.1 b/Documentation/nvme.1 index f1593d9..6162752 100644 --- a/Documentation/nvme.1 +++ b/Documentation/nvme.1 @@ -2,12 +2,12 @@ .\" Title: nvme .\" Author: [see the "Authors" section] .\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/> -.\" Date: 11/11/2021 +.\" Date: 04/08/2022 .\" Manual: NVMe Manual .\" Source: NVMe .\" Language: English .\" -.TH "NVME" "1" "11/11/2021" "NVMe" "NVMe Manual" +.TH "NVME" "1" "04/08/2022" "NVMe" "NVMe Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- @@ -73,7 +73,7 @@ Retrieve error logs Submit flush .RE .PP -\fBnvme-dms\fR(1) +\fBnvme-dsm\fR(1) .RS 4 Submit Data Set Management .RE @@ -323,6 +323,11 @@ Discover and connect to all NVMe\-over\-Fabrics subsystems Connect to an NVMe\-over\-Fabrics subsystem .RE .PP +\fBnvme-dim\fR(1) +.RS 4 +Send Discovery Information Management command to a Discovery Controller +.RE +.PP \fBnvme-disconnect\fR(1) .RS 4 Disconnect from an NVMe\-over\-Fabrics subsystem @@ -337,6 +342,507 @@ Disconnect from all NVMe\-over\-Fabrics subsystems .RS 4 Reads and shows NVMe\-over\-Fabrics controller property .RE +.PP +\fBnvme-media-unit-stat-log\fR(1) +.RS 4 +Retrieve and show the configuration and wear of media units +.RE +.PP +\fBnvme-supported-cap-config-log\fR(1) +.RS 4 +Retrieve and show the list of Supported Capacity Configuration Descriptors +.RE +.PP +\fBnvme-boot-part-log\fR(1) +.RS 4 +Retrieve Boot Partition Log +.RE +.PP +\fBnvme-capacity-mgmt\fR(1) +.RS 4 +Capacity Management Command +.RE +.PP +\fBnvme-check-dhchap-key\fR(1) +.RS 4 +Generate NVMeoF DH\-HMAC\-CHAP host key +.RE +.PP +\fBnvme-check-tls-key\fR(1) +.RS 4 +Validate NVMeoF TLS PSK +.RE +.PP +\fBnvme-cmdset-ind-id-ns\fR(1) +.RS 4 +I/O Command Set Independent Identify Namespace +.RE +.PP +\fBnvme-endurance-event-agg-log\fR(1) +.RS 4 +Retrieve Endurance Group Event Aggregate Log +.RE +.PP +\fBnvme-fid-support-effects-log\fR(1) +.RS 4 +Retrieve FID Support and Effects log +.RE +.PP +\fBnvme-gen-dhchap-key\fR(1) +.RS 4 +Generate NVMeoF DH\-HMAC\-CHAP host key +.RE +.PP +\fBnvme-gen-hostnqn\fR(1) +.RS 4 +Generate NVMeoF host NQN +.RE +.PP +\fBnvme-gen-tls-key\fR(1) +.RS 4 +Generate NVMeoF TLS PSK +.RE +.PP +\fBnvme-get-lba-status\fR(1) +.RS 4 +Get LBA Status command +.RE +.PP +\fBnvme-id-domain\fR(1) +.RS 4 +NVMe Identify Domain List +.RE +.PP +\fBnvme-id-ns-lba-format\fR(1) +.RS 4 +NVMe Identify Namespace for the specified LBA Format index +.RE +.PP +\fBnvme-lba-status-log\fR(1) +.RS 4 +Retrieve LBA Status Information Log +.RE +.PP +\fBnvme-list-endgrp\fR(1) +.RS 4 +NVMe Identify Endurance Group List +.RE +.PP +\fBnvme-ns-rescan\fR(1) +.RS 4 +Rescans the NVME namespaces +.RE +.PP +\fBnvme-nvm-id-ctrl\fR(1) +.RS 4 +NVMe Identify Controller NVM Command Set +.RE +.PP +\fBnvme-nvm-id-ns\fR(1) +.RS 4 +NVMe Identify Namespace NVM Command Set +.RE +.PP +\fBnvme-nvm-id-ns-lba-format\fR(1) +.RS 4 +NVMe Identify Namespace NVM Command Set for the specified LBA Format index +.RE +.PP +\fBnvme-persistent-event-log\fR(1) +.RS 4 +Retrieve Presistent Event Log +.RE +.PP +\fBnvme-predictable-lat-log\fR(1) +.RS 4 +Retrieve Predictable Latency per Nvmset Log +.RE +.PP +\fBnvme-pred-lat-event-agg-log\fR(1) +.RS 4 +Retrieve Predictable Latency Event Aggregate Log +.RE +.PP +\fBnvme-primary-ctrl-caps\fR(1) +.RS 4 +NVMe Identify Primary Controller Capabilities +.RE +.PP +\fBnvme-reset\fR(1) +.RS 4 +Resets the controller +.RE +.PP +\fBnvme-rpmb\fR(1) +.RS 4 +Replay Protection Memory Block commands +.RE +.PP +\fBnvme-sanitize-log\fR(1) +.RS 4 +Retrieve sanitize log +.RE +.PP +\fBnvme-set-property\fR(1) +.RS 4 +Set a property and show the resulting value +.RE +.PP +\fBnvme-show-hostnqn\fR(1) +.RS 4 +Show NVMeoF host NQN +.RE +.PP +\fBnvme-subsystem-reset\fR(1) +.RS 4 +Resets the subsystem +.RE +.PP +\fBnvme-supported-log-pages\fR(1) +.RS 4 +Retrieve the Supported Log pages details +.RE +.PP +\fBnvme-verify\fR(1) +.RS 4 +verify command +.RE +.SS "Plugins/Vendor extension commands" +.PP +\fBnvme-intel-id-ctrl\fR(1) +.RS 4 +Intel \- NVMe Identify Controller +.RE +.PP +\fBnvme-intel-internal-log\fR(1) +.RS 4 +Retrieve Intel device\(cqs internal log and save to file +.RE +.PP +\fBnvme-intel-lat-stats\fR(1) +.RS 4 +Retrieve NVMe Identify Controller, return result and structure +.RE +.PP +\fBnvme-intel-market-name\fR(1) +.RS 4 +Intel vendor specific marketing name log page +.RE +.PP +\fBnvme-intel-smart-log-add\fR(1) +.RS 4 +NVMe Intel Additional SMART log page +.RE +.PP +\fBnvme-intel-temp-stats\fR(1) +.RS 4 +NVMe Intel Additional SMART log page for temp stats +.RE +.PP +\fBnvme-huawei-id-ctrl\fR(1) +.RS 4 +NVMe huawei Identify Controller +.RE +.PP +\fBnvme-huawei-list\fR(1) +.RS 4 +List all recognized Huawei NVMe devices +.RE +.PP +\fBnvme-dera-stat\fR(1) +.RS 4 +NVMe Dera Device status and Additional SMART log page request +.RE +.PP +\fBnvme-micron-clear-pcie-errors\fR(1) +.RS 4 +Clears correctable PCIe correctable errors of given Micron device +.RE +.PP +\fBnvme-micron-internal-log\fR(1) +.RS 4 +Retrieve Micron device\(cqs internal logs and save to given zip file +.RE +.PP +\fBnvme-micron-nand-stats\fR(1) +.RS 4 +Retrieves NAND statistics of given micron device +.RE +.PP +\fBnvme-micron-pcie-stats\fR(1) +.RS 4 +Retrieves pcie error statistics for given micron device +.RE +.PP +\fBnvme-micron-selective-download\fR(1) +.RS 4 +Performs selective firmware download +.RE +.PP +\fBnvme-micron-smart-add-log\fR(1) +.RS 4 +Retrieves NAND statistics +.RE +.PP +\fBnvme-micron-temperature-stats\fR(1) +.RS 4 +Retrieves temperature information of given micron device +.RE +.PP +\fBnvme-netapp-ontapdevices\fR(1) +.RS 4 +Display information about ONTAP devices +.RE +.PP +\fBnvme-netapp-smdevices\fR(1) +.RS 4 +Display information for each NVMe path to an E\-Series volume +.RE +.PP +\fBnvme-toshiba-clear-pcie-correctable-errors\fR(1) +.RS 4 +Reset the PCIe correctable errors count to zero +.RE +.PP +\fBnvme-toshiba-vs-internal-log\fR(1) +.RS 4 +Retrieve a Toshiba device\(cqs vendor specific internal log +.RE +.PP +\fBnvme-toshiba-vs-smart-add-log\fR(1) +.RS 4 +Retrieve a Toshiba device\(cqs vendor specific extended SMART log page +.RE +.PP +\fBnvme-transcend-badblock\fR(1) +.RS 4 +Retrieve Transcend NVMe device\(cqs bad blocks +.RE +.PP +\fBnvme-transcend-healthvalue\fR(1) +.RS 4 +Use NVMe SMART table to analyse the health value of Transcend device +.RE +.PP +\fBnvme-virtium-show-identify\fR(1) +.RS 4 +Show a complete detail of identify device information in json format +.RE +.PP +\fBnvme-virtium-save-smart-to-vtview-log\fR(1) +.RS 4 +Periodically save smart attributes into a log file +.RE +.PP +\fBnvme-wdc-cap-diag\fR(1) +.RS 4 +Retrieve WDC device\(cqs diagnostic log and save to file +.RE +.PP +\fBnvme-wdc-capabilities\fR(1) +.RS 4 +Display WDC plugin command capabilities +.RE +.PP +\fBnvme-wdc-clear-assert-dump\fR(1) +.RS 4 +Clears the assert dump (if present) +.RE +.PP +\fBnvme-wdc-clear-fw-activate-history\fR(1) +.RS 4 +Clears the firmware activate history table +.RE +.PP +\fBnvme-wdc-clear-pcie-corr\fR(1) +.RS 4 +Clears the pcie correctable errors field +.RE +.PP +\fBnvme-wdc-clear-pcie-correctable-errors\fR(1) +.RS 4 +Clears the pcie correctable errors returned in the smart\-log\-add command +.RE +.PP +\fBnvme-wdc-cloud-SSD-plugin-version\fR(1) +.RS 4 +Display WDC plugin Cloud SSD Plugin Version +.RE +.PP +\fBnvme-wdc-drive-essentials\fR(1) +.RS 4 +Retrieve WDC device\(cqs drive essentials bin files +.RE +.PP +\fBnvme-wdc-drive-log\fR(1) +.RS 4 +Retrieve WDC device\(cqs drive log and save to file +.RE +.PP +\fBnvme-wdc-drive-resize\fR(1) +.RS 4 +Send NVMe WDC Resize Vendor Unique Command +.RE +.PP +\fBnvme-wdc-enc-get-log\fR(1) +.RS 4 +Send NVMe WDC enc\-get\-log Vendor Unique Command +.RE +.PP +\fBnvme-wdc-get-crash-dump\fR(1) +.RS 4 +Retrieve WDC device\(cqs crash dump +.RE +.PP +\fBnvme-wdc-get-drive-status\fR(1) +.RS 4 +Send the NVMe WDC get\-drive\-status command +.RE +.PP +\fBnvme-wdc-get-latency-monitor-log\fR(1) +.RS 4 +Display latency monitor log page data in human readable format +.RE +.PP +\fBnvme-wdc-get-pfail-dump\fR(1) +.RS 4 +Retrieve WDC device\(cqs pfail crash dump +.RE +.PP +\fBnvme-wdc-id-ctrl\fR(1) +.RS 4 +Send NVMe Identify Controller, return result and structure +.RE +.PP +\fBnvme-wdc-log-page-directory\fR(1) +.RS 4 +Retrieves the list of Log IDs supported by the drive +.RE +.PP +\fBnvme-wdc-namespace-resize\fR(1) +.RS 4 +Resizes the device\(cqs namespace +.RE +.PP +\fBnvme-wdc-purge-monitor\fR(1) +.RS 4 +Send NVMe WDC Purge\-Monitor Vendor Unique Command +.RE +.PP +\fBnvme-wdc-purge\fR(1) +.RS 4 +Send NVMe WDC Purge Vendor Unique Command +.RE +.PP +\fBnvme-wdc-smart-add-log\fR(1) +.RS 4 +Send NVMe WDC smart add log Vendor Unique Command +.RE +.PP +\fBnvme-wdc-vs-drive-info\fR(1) +.RS 4 +Send the NVMe WDC vs\-drive\-info command +.RE +.PP +\fBnvme-wdc-vs-error-reason-identifier\fR(1) +.RS 4 +Retrieve WDC device\(cqs telemetry log error reason identifier field +.RE +.PP +\fBnvme-wdc-vs-fw-activate-history\fR(1) +.RS 4 +Execute NVMe WDC vs\-fw\-activate\-history Vendor Unique Command +.RE +.PP +\fBnvme-wdc-vs-internal-log\fR(1) +.RS 4 +Retrieve WDC device\(cqs internal firmware log and save to file +.RE +.PP +\fBnvme-wdc-vs-nand-stats\fR(1) +.RS 4 +Send NVMe WDC vs\-nand\-stats Vendor Unique Command +.RE +.PP +\fBnvme-wdc-vs-telemetry-controller-option\fR(1) +.RS 4 +Disable/Enable the controller initiated option of the telemetry log page +.RE +.PP +\fBnvme-wdc-vs-temperature-stats\fR(1) +.RS 4 +Display temperature\-related statistics +.RE +.PP +\fBnvme-zns-changed-zone-list\fR(1) +.RS 4 +Retrieve Changed Zone log for the given device +.RE +.PP +\fBnvme-zns-close-zone\fR(1) +.RS 4 +Closes one or all zones +.RE +.PP +\fBnvme-zns-finish-zone\fR(1) +.RS 4 +Finishes one or all zones +.RE +.PP +\fBnvme-zns-id-ctrl\fR(1) +.RS 4 +Send NVMe Zoned Command Set Identify Controller +.RE +.PP +\fBnvme-zns-id-ns\fR(1) +.RS 4 +Send NVMe Zoned Command Set Identify Namespace +.RE +.PP +\fBnvme-zns-offline-zone\fR(1) +.RS 4 +Offlines one or all zones +.RE +.PP +\fBnvme-zns-open-zone\fR(1) +.RS 4 +Opens one or all zones +.RE +.PP +\fBnvme-zns-report-zones\fR(1) +.RS 4 +Retrieve and display the Report Zones data structure +.RE +.PP +\fBnvme-zns-reset-zone\fR(1) +.RS 4 +Resets one or all zones +.RE +.PP +\fBnvme-zns-set-zone-desc\fR(1) +.RS 4 +Set extended descriptor data for a zone +.RE +.PP +\fBnvme-zns-zone-append\fR(1) +.RS 4 +Send an NVMe write command, provide results +.RE +.PP +\fBnvme-zns-zone-mgmt-recv\fR(1) +.RS 4 +Zone Management Receive command +.RE +.PP +\fBnvme-zns-zone-mgmt-send\fR(1) +.RS 4 +Zone Management Send command +.RE +.PP +\fBnvme-zns-zrwa-flush-zone\fR(1) +.RS 4 +Flush LBAs associated with a ZRWA to a zone +.RE .SH "FURTHER DOCUMENTATION" .sp See the freely available references on the \m[blue]\fBOfficial NVM\-Express Site\fR\m[]\&\s-2\u[1]\d\s+2\&. |