From 5b7ddc4bd2dcdde201ffa2681ede9a0a029bad96 Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Fri, 2 Jul 2021 22:47:46 +0200 Subject: Adding upstream version 1.14. Signed-off-by: Daniel Baumann --- Documentation/nvme-pred-lat-event-agg-log.html | 870 +++++++++++++++++++++++++ 1 file changed, 870 insertions(+) create mode 100644 Documentation/nvme-pred-lat-event-agg-log.html (limited to 'Documentation/nvme-pred-lat-event-agg-log.html') diff --git a/Documentation/nvme-pred-lat-event-agg-log.html b/Documentation/nvme-pred-lat-event-agg-log.html new file mode 100644 index 0000000..42c370f --- /dev/null +++ b/Documentation/nvme-pred-lat-event-agg-log.html @@ -0,0 +1,870 @@ + + + + + + +nvme-pred-lat-event-agg-log(1) + + + + + +
+
+

SYNOPSIS

+
+
+
nvme pred-lat-event-agg-log <device> [--log-entries=<log_entries> | -e <log_entries>]
+                        [--rae | -r] [--raw-binary | -b]
+                        [--output-format=<fmt> | -o <fmt>]
+
+
+
+
+
+

DESCRIPTION

+
+

Retrieves the NVMe Predictable Latency Event Aggregate Log Page from an +NVMe device and provides the returned structure.

+

The <device> parameter is mandatory and may be either the NVMe character +device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).

+

On success, the returned Predictable Latency Event Aggregate Log +Page structure may be returned in one ofseveral ways depending on +the option flags; the structure may parsed by the program and printed +in a readable format or the raw buffer may be printed to stdout for +another program to parse.

+
+
+
+

OPTIONS

+
+
+
+-e <log_entries> +
+
+--log-entries=<log_entries> +
+
+

+ Retrieve the Predictable Latency Event Aggregate Log pending entries. + This argument is mandatory and its success may depend on the device’s + statistics to provide this log For More details see NVM Express 1.4 Spec. + Section 5.14.1.11. The maximum number of log entries supported is 2044 + for the device. +

+
+
+-r +
+
+--rae +
+
+

+ Retain an Asynchronous Event. +

+
+
+-b +
+
+--raw-binary +
+
+

+ Print the raw Predectible Latency Event Aggregate log buffer to stdout. +

+
+
+-o <format> +
+
+--output-format=<format> +
+
+

+ Set the reporting format to normal, json, or binary. + Only one output format can be used at a time. +

+
+
+
+
+
+

EXAMPLES

+
+
    +
  • +

    +Print the Predictable Latency Event Aggregate Log page in a human readable format: +

    +
    +
    +
    # nvme pred-lat-event-agg-log /dev/nvme0
    +
    +
  • +
  • +

    +Print the raw Predectible Latency Event Aggregate log to a file: +

    +
    +
    +
    # nvme pred-lat-event-agg-log /dev/nvme0 --raw-binary > pred_lat_agg_log.raw
    +
    +

    It is probably a bad idea to not redirect stdout when using this mode.

    +
  • +
+
+
+
+