'\" t
.\" Title: nvme-wdc-get-drive-status
.\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author]
.\" Generator: DocBook XSL Stylesheets vsnapshot
.\" Date: 04/24/2020
.\" Manual: NVMe Manual
.\" Source: NVMe
.\" Language: English
.\"
.TH "NVME\-WDC\-GET\-DRIV" "1" "04/24/2020" "NVMe" "NVMe Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
nvme-wdc-get-drive-status \- Send the NVMe WDC get\-drive\-status command, return result
.SH "SYNOPSIS"
.sp
.nf
\fInvme wdc get\-drive\-status\fR
.fi
.SH "DESCRIPTION"
.sp
For the NVMe device given, send the unique WDC get\-drive\-status command and provide the additional drive status information\&.
.sp
The parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0)\&.
.sp
This will only work on WDC devices supporting this feature\&. Results for any other device are undefined\&.
.sp
On success it returns 0, error code otherwise\&.
.SH "OUTPUT EXPLANATION"
.TS
allbox tab(:);
ltB ltB.
T{
Field
T}:T{
Description
T}
.T&
lt lt
lt lt
lt lt
lt lt
lt lt.
T{
.sp
\fBPercent Life Used\&.\fR
T}:T{
.sp
The percentage of drive function used\&.
T}
T{
.sp
\fBEOL (End of Life) Status\fR
T}:T{
.sp
The 3 possible states are : Normal, Read Only, or End of Life\&.
T}
T{
.sp
\fBAssert Dump Status\fR
T}:T{
.sp
The 2 possible states are : Present or Not Present\&.
T}
T{
.sp
\fBThermal Throttling Status\fR
T}:T{
.sp
The 3 possible states are : Off, On, or Unavaiable\&.
T}
T{
.sp
\fBFormat Corrupt Reason\fR
T}:T{
.sp
The 3 possible states are : Not Corrupted, Corrupt due to FW Assert, or Corrupt for Unknown Reason\&.
T}
.TE
.sp 1
.SH "EXAMPLES"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Has the program issue WDC get\-drive\-status command :
.sp
.if n \{\
.RS 4
.\}
.nf
# nvme wdc get\-drive\-status /dev/nvme0
.fi
.if n \{\
.RE
.\}
.RE
.SH "NVME"
.sp
Part of the nvme\-user suite\&.