'\" t
.\" Title: nvme-wdc-purge-monitor
.\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author]
.\" Generator: DocBook XSL Stylesheets vsnapshot
.\" Date: 07/14/2022
.\" Manual: NVMe Manual
.\" Source: NVMe
.\" Language: English
.\"
.TH "NVME\-WDC\-PURGE\-MO" "1" "07/14/2022" "NVMe" "NVMe Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
nvme-wdc-purge-monitor \- Send NVMe WDC Purge\-Monitor Vendor Unique Command, return result
.SH "SYNOPSIS"
.sp
.nf
\fInvme wdc purge\-monitor\fR
.fi
.SH "DESCRIPTION"
.sp
For the NVMe device given, send a Vendor Unique WDC Purge\-Monitor command and provide the status of the purge command\&.
.sp
Expected status and description :\-
.TS
allbox tab(:);
ltB ltB.
T{
Status Code
T}:T{
Description
T}
.T&
lt lt
lt lt
lt lt
lt lt
lt lt.
T{
.sp
0x00
T}:T{
.sp
Purge State Idle\&.
T}
T{
.sp
0x01
T}:T{
.sp
Purge State Done\&.
T}
T{
.sp
0x02
T}:T{
.sp
Purge State Busy\&.
T}
T{
.sp
0x03
T}:T{
.sp
Purge State Error : Purge operation resulted in error, power cycle required\&.
T}
T{
.sp
0x04
T}:T{
.sp
Purge State Error : Purge operation interrupted by power cycle or reset\&.
T}
.TE
.sp 1
.sp
The parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1)\&.
.sp
This will only work on WDC devices supporting this feature\&. Results for any other device are undefined\&.
.sp
On success it returns 0, error code otherwise\&.
.SH "OPTIONS"
.sp
No options yet\&.
.SH "EXAMPLES"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Has the program issue WDC Purge\-Monitor Vendor Unique Command :
.sp
.if n \{\
.RS 4
.\}
.nf
# nvme wdc purge\-monitor /dev/nvme0
.fi
.if n \{\
.RE
.\}
.RE
.SH "NVME"
.sp
Part of the nvme\-user suite\&.