'\" t
.\" Title: nvme-wdc-vs-cloud-log
.\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author]
.\" Generator: DocBook XSL Stylesheets vsnapshot
.\" Date: 06/30/2023
.\" Manual: NVMe Manual
.\" Source: NVMe
.\" Language: English
.\"
.TH "NVME\-WDC\-VS\-CLOUD" "1" "06/30/2023" "NVMe" "NVMe Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
nvme-wdc-vs-cloud-log \- Send NVMe WDC vs\-cloud\-log Vendor Unique Command, return result
.SH "SYNOPSIS"
.sp
.nf
\fInvme wdc vs\-cloud\-log\fR [\-\-output\-format= \-o ]
[\-\-namespace\-id= | \-n ]
.fi
.SH "DESCRIPTION"
.sp
For the NVMe device given, send a Vendor Unique WDC vs\-cloud\-log command and provide the smart/health log\&.
.sp
The parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0) or block device (ex: /dev/nvme0n1)\&.
.sp
This will only work on WDC devices supporting this feature\&. Results for any other device are undefined\&.
.sp
On success it returns 0, error code otherwise\&.
.SH "OPTIONS"
.PP
\-o , \-\-output\-format=
.RS 4
Set the reporting format to
\fInormal\fR, or
\fIjson\fR\&. Only one output format can be used at a time\&. Default is normal\&.
.RE
.PP
\-n , \-\-namespace\-id=
.RS 4
Sets the command\(cqs nsid value to the given nsid\&. Defaults to 0xffffffff if not given\&. This option may not affect anything depending on the log page, which may or may not be specific to a namespace\&.
.RE
.SH "EXAMPLES"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Has the program issue WDC vs\-cloud\-log Vendor Unique Command :
.sp
.if n \{\
.RS 4
.\}
.nf
# nvme wdc vs\-cloud\-log /dev/nvme0
.fi
.if n \{\
.RE
.\}
.RE
.SH "NVME"
.sp
Part of the nvme\-user suite\&.